Circuit DescriptionThe ECM continuously monitors the engine’s fault code status to determine if any fault codes critical to successful engine operation are active.

Component LocationThe ECM mounting location varies, depending on the engine model, and may be mounted either on or off the engine.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine has been operated for an extended amount of time with critical SCR faults active, and no repair action has been taken. This amount of time will vary, depending on which SCR faults are active.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.Engine Torque will be reduced.Vehicle speed will be limited to 8 km [5 mi] per hour.Conditions for Clearing the Fault CodeThis fault code will go inactive once all other active fault codes have been addressed. Refer to the appropriate fault code troubleshooting tree.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.

Shop TalkThis fault code is for information only, and indicates that an engine power derate and vehicle speed limit have been implemented in order to make sure that the critical SCR related fault codes that are presently active in the ECM are addressed as quickly as possible.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3697 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory- Bad Intelligent Device or Component
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3682 PID: PID 190 SPN: 3218 FMI: 2 Aftertreatment Intake Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3681 PID: PID 411 SPN: 3228 FMI: 2 Aftertreatment Outlet Nox Sensor Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3649 PID: SPN: 5024 FMI: 10 Aftertreatment Intake Nox Sensor Heater- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3596 PID: SPN: 4334 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 3583 PID: SPN: 5031 FMI: 10 Aftertreatment Outlet Nox Sensor Heater- Abnormal Rate of Change