Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 235 PID: PID 111 SPN: 111 FMI: 1 Coolant Level- Data Valid But Below Normal Operational Range- Most Severe Level

Circuit DescriptionThe coolant level sensor is a switch and is used to measure the level of the engine coolant in the radiator top tank. The coolant level sensor is immersed in the coolant and returns a different signal voltage when immersed in coolant versus being out of coolant. The engine control module (ECM) monitors the change in the signal voltage to determine the level of the engine coolant.

Component LocationThe engine coolant level sensor is typically located in the radiator top tank or surge tank. Refer to the OEM service manual for the location.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the coolant level sensor signal voltage was greater than 3-VDC for more than 30 seconds, indicating severely low coolant level.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp immediately after the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.The engine will be shut down if the Engine Protection Shutdown feature is enabled.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for up to 5 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Low coolant level

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 234 PID: PID 190 SPN: 190 FMI: 0 Engine Crankshaft Speed/Position- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 227 PID: SID 211 SPN: 3510 FMI: 3 Sensor Supply 2 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 222 PID: PID 108 SPN: 108 FMI: 4 Barometric Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 221 PID: PID 108 SPN: 108 FMI: 3 Barometric Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 214 PID: PID 175 SPN: 175 FMI: 0 Engine Oil Temperature- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 213 PID: PID 175 SPN: 175 FMI: 4 Engine Oil Temperature Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source