Circuit DescriptionThe aftertreatment diesel exhaust fluid quality sensor is a smart device that communicates to the ECM via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor performs its own internal diagnostics and reports malfunctions back to the primary engine control module via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor is used to measure the concentration of the aftertreatment diesel exhaust fluid in the tank.

Component LocationThe aftertreatment diesel exhaust fluid quality sensor is located in the aftertreatment diesel exhaust fluid tank. It may be a combination sensor with the aftertreatement diesel exhaust fluid tank level and tank temperature sensors. Location of the tank and sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe DEF quality sensor has reported an internal error.

Action Taken When the Fault Code is ActiveThe ECM will illuminate the amber CHECK ENGINE light immediately when the diagnostic runs and fails.

Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.

Shop TalkPossible caused of this fault code include:

Malfunctioning Aftertreatment DEF Quality Sensor.

Possible Cause:1) Aftertreatment DEF quality sensor failure2) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1713 PID: SPN: 3363 FMI: 16 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1712 PID: SPN: 3363 FMI: 18 Aftertreatment Diesel Exhaust Fluid Tank Heater- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1696 PID: SID 232 SPN: 3513 FMI: 4 Sensor Supply 5- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1695 PID: SID 232 SPN: 3513 FMI: 3 Sensor Supply 5- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1694 PID: PID 2201 SPN: 3226 FMI: 2 Aftertreatment 1 Outlet Nox Sensor- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1691 PID: SID 380 SPN: 5298 FMI: 18 Aftertreatment Diesel Oxidation Catalyst Conversion Efficiency- Data Valid But Below Normal Operating Range- Moderately Severe Level