Cummins ISX12 CM2250 (2010-12) Fault Code: 3213 PID: SPN: 1623 FMI: 19 Tachograph Output Shaft Speed- Received Network Data In Error

Circuit DescriptionNormally, switches, accelerators, and other components are connected to the engine electronic control module (ECM) directly through individual wires. Multiplexing allows those same components to be hard wired to an original equipment manufacturer (OEM) VECU or transmission electronic control unit in the cab. Component values and states from components (such as sensors, accelerators, and switches) can then be transmitted from the OEM VECU to the Cummins? engine ECM over the SAE J1939 data link. Messages sent from the OEM VECU or transmission electronic control unit are received by the Cummins? engine ECM and used for controlling the engine. The Cummins? ECM and OEM VECU must be configured properly so that proper operation of the multiplexed components will occur.

Component LocationThe J1939 data link wiring and VECU location varies by OEM.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the key switch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe OEM VECU determines that there is a malfunction of the tachograph output shaft speed sensor.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe J1939 multiplexing controller has indicated a malfunction of the tachograph output shaft speed sensor.

Possible Cause:1) ECM calibration

Cummins ISX12 CM2250 (2010-12) Fault Code: 3186 PID: SPN: 1623 FMI: 9 Tachograph Output Shaft Speed- Abnormal Update Rate
Cummins ISX12 CM2250 (2010-12) Fault Code: 3168 PID: SPN: 3936 FMI: 16 Aftertreatment Diesel Particulate Filter System- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins ISX12 CM2250 (2010-12) Fault Code: 3167 PID: SID 382 SPN: 3556 FMI: 18 Aftertreatment Doser- Data valid But Below Normal Operating Range- Moderately Severe Level
Cummins ISX12 CM2250 (2010-12) Fault Code: 3165 PID: SPN: 4363 FMI: 0 Aftertreatment 1 SCR Outlet Temperature- Data Valid But Above Normal Operating range- Most Severe Level
Cummins ISX12 CM2250 (2010-12) Fault Code: 3164 PID: SPN: 4360 FMI: 15 Aftertreatment SCR Intake Temperature- DataValid But Above Normal Operating Range- Least Severe Level
Cummins ISX12 CM2250 (2010-12) Fault Code: 3151 (MR) PID: SPN: 4794 FMI: 31 Aftertreatment SCR catalyst System Missing- Condition Exists

Comparte este mensaje...

Publicación anterior Siguiente Mensaje