Cummins ISX CM870 (2003-06) Fault Code: 435 PID: P100 SPN: 100 FMI: 2/2 Engine Oil Pressure Sensor Circuit – data incorrect. An error in the engine oil pressure sensor signal was detected by the ECM.

At key-on, before the engine is started, the sensor readings for barometric pressure, exhaust gas pressure, and intake manifold pressure are compared with engine oil pressure. This fault code occurs if the engine oil pressure sensor reading is different from any two of the other three. This check is only done once after the keyswitch is turned on and before the engine is started. The engine oil temperature must also be at least 7?C [45?F] for this check to run.

Shop exhaust fans can cause this fault code to come active. Turn exhaust fans off when troubleshooting this fault code.

Possible repair:

1)Repair or replace the engine oil pressure switch.

Cummins ISX CM870 (2003-06) Fault Code: 434 PID: S251 SPN: 627 FMI: 2/2 Power Lost Without Ignition OFF. Supply voltage to the ECM fell below 6.2 volts momentarily, or the ECM was not allowed to power down correctly (retain battery voltage for 30 seconds after key OFF).
Cummins ISX CM870 (2003-06) Fault Code: 433 PID: P102 SPN: 102 FMI: 2/2 Intake Manifold Pressure Sensor Circuit – Data Incorrect. An error in the intake manifold pressure signal was detected by the ECM.
Cummins ISX CM870 (2003-06) Fault Code: 432 PID: S230 SPN: 558 FMI: 13/13 Accelerator Pedal Idle Validation Circuit – out of calibration. Voltage at idle validation on-idle and off-idle circuit does not match accelerator pedal position.
Cummins ISX CM870 (2003-06) Fault Code: 431 (SSS) PID: S230 SPN: 558 FMI: 2/2 Accelerator Pedal Idle Validation Circuit – data incorrect. Voltage detected simultaneously on both idle validation and off-idle validation switches.
Cummins ISX CM870 (2003-06) Fault Code: 431 (ISS) PID: S230 SPN: 558 FMI: 2/2 Accelerator Pedal Idle Validation Circuit – data incorrect. Voltage detected simultaneously on both idle validation and off-idle validation switches.