Allison WTEC II Fault Code: 56 PID: SPN: 00 FMI: Range verification test, L
Publicado por Diezel Solutions en
Main code 56 indicates a failed range verification speed sensor ratio test. Range verification ratio test (between shifts) L The ratio test occurs after a shift and determines if a clutch has lost torque carrying capability. If output speed is above programmed output speed for a range but the correct speed sensor ratio is not present, the DO NOT SHIFT response is commanded and a range which can carry the torque without damage is commanded or attempted. Turbine and output speed sensor readings are used to calculate the actual ratio that is compared to the commanded ratio. Main code 56...
Allison WTEC II Fault Code: 56 PID: SPN: 11 FMI: Range verification ratio test, 1st
Publicado por Diezel Solutions en
Main code 56 indicates a failed range verification speed sensor ratio test. Range verification ratio test (between shifts) 1 The ratio test occurs after a shift and determines if a clutch has lost torque carrying capability. If output speed is above programmed output speed for a range but the correct speed sensor ratio is not present, the DO NOT SHIFT response is commanded and a range which can carry the torque without damage is commanded or attempted. Turbine and output speed sensor readings are used to calculate the actual ratio that is compared to the commanded ratio. Main code 56...
Allison WTEC II Fault Code: 56 PID: SPN: 22 FMI: Range verification ratio test, 2nd
Publicado por Diezel Solutions en
Main code 56 indicates a failed range verification speed sensor ratio test. Range verification ratio test (between shifts) 2 The ratio test occurs after a shift and determines if a clutch has lost torque carrying capability. If output speed is above programmed output speed for a range but the correct speed sensor ratio is not present, the DO NOT SHIFT response is commanded and a range which can carry the torque without damage is commanded or attempted. Turbine and output speed sensor readings are used to calculate the actual ratio that is compared to the commanded ratio. Main code 56...
Allison WTEC II Fault Code: 56 PID: SPN: 33 FMI: Range verification ratio test, 3rd
Publicado por Diezel Solutions en
Main code 56 indicates a failed range verification speed sensor ratio test. Range verification ratio test (between shifts) 3 The ratio test occurs after a shift and determines if a clutch has lost torque carrying capability. If output speed is above programmed output speed for a range but the correct speed sensor ratio is not present, the DO NOT SHIFT response is commanded and a range which can carry the torque without damage is commanded or attempted. Turbine and output speed sensor readings are used to calculate the actual ratio that is compared to the commanded ratio. Main code 56...
Allison WTEC II Fault Code: 56 PID: SPN: 44 FMI: Range verification ratio test, 4th
Publicado por Diezel Solutions en
Main code 56 indicates a failed range verification speed sensor ratio test. Range verification ratio test (between shifts) 4 The ratio test occurs after a shift and determines if a clutch has lost torque carrying capability. If output speed is above programmed output speed for a range but the correct speed sensor ratio is not present, the DO NOT SHIFT response is commanded and a range which can carry the torque without damage is commanded or attempted. Turbine and output speed sensor readings are used to calculate the actual ratio that is compared to the commanded ratio. Main code 56...