Paccar– Page 111– ⛽ Diezel365


Paccar

PACCAR PX-6 CM2150 (2007-09) Fault Code: 131 PID: 91 SPN: 91 FMI: 3 Accelerator Pedal or Lever Position Sensor 1 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at accelerator pedal position number 1 circuit.

Posted by Diezel Solutions on

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. Newer engines use two throttle position sensors to determine the throttle position. Older throttle pedals used a single throttle position sensor and an idle validation switch. If Fault Codes 132 and 1241 are active when the accelerator pedal is in the idle position, and Fault Code 132 goes inactive, and Fault Code 1239 goes active when the throttle is depressed, the incorrect throttle pedal has been installed...

Read more →


PACCAR PX-6 CM2150 (2007-09) Fault Code: 132 PID: 91 SPN: 91 FMI: 4 Accelerator Pedal or Lever Position Sensor 1 Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at accelerator pedal position number 1 signal circuit.

Posted by Diezel Solutions on

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. Newer engines use two throttle position sensors to determine the throttle position. Older throttle pedals used a single throttle position sensor and an idle validation switch. If Fault Codes 132 and 1241 are active when the accelerator pedal is in the idle position and Fault Code 132 goes inactive and Fault Code 1239 goes active when the throttle is depressed, the incorrect throttle pedal has been installed...

Read more →


PACCAR PX-6 CM2150 (2007-09) Fault Code: 133 PID: 372 SPN: 974 FMI: 3 Remote Accelerator Pedal or Lever Position Sensor 1 Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage detected at remote accelerator position signal circuit.

Posted by Diezel Solutions on

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. If troubleshooting an intermittent accelerator problem: The remote accelerator pedal or lever position sensor signal voltage can be monitored with the INSITE™ electronic service tool, while flexing the harness to locate the intermittent connection. Intermittent connections will show up as abrupt changes in signal voltage displayed by the INSITE™ electronic service tool. Possible causes: 1)Remote accelerator pedal or lever position signal circuit shorted to battery or +5...

Read more →


PACCAR PX-6 CM2150 (2007-09) Fault Code: 134 PID: 372 SPN: 974 FMI: 4 Remote Accelerator Pedal or Lever Position Sensor 1 Circuit – Voltage Below Normal or Shorted to Low Source. Low voltage detected at remote accelerator position signal circuit.

Posted by Diezel Solutions on

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. If troubleshooting an intermittent accelerator problem: The remote accelerator pedal or lever position sensor signal voltage can be monitored with the INSITE™ electronic service tool, while flexing the harness to locate the intermittent connection. Intermittent connections will show up as abrupt changes in signal voltage displayed by the INSITE™ electronic service tool. Possible causes: 1)Remote accelerator pedal or lever position signal circuit shorted to battery or +5...

Read more →


PACCAR PX-6 CM2150 (2007-09) Fault Code: 135 PID: 100 SPN: 100 FMI: 3 Engine Oil Rifle Pressure 1 Sensor Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage detected at the engine oil pressure circuit.

Posted by Diezel Solutions on

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM. The oil pressure sensor shares supply and return wires in the engine harness with other sensors. Opens and shorts in the engine harness can cause multiple fault codes to be active. Before troubleshooting Fault Code 135, check for multiple fault codes. Possible causes: 1)Open return circuit in the harness, connectors, or sensor2)Signal circuit shorted to sensor supply or battery voltage. Possible repairs: 1)Replace the oil pressure sensor.2)Replace...

Read more →