Skip to content

Telegram : @Diezel365

PACCAR PX-9 CM2350 (2013-17) Fault Code:2185 PID:SID 232 SPN:3512 FMI:3 Sensor Supply 4 Circuit – Voltage Above Normal or Shorted to High Source

Reason:
Sensor Supply 4 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at 5 VDC sensor supply circuit to the accelerator pedal position sensor.

Effect:
Engine will only idle.

Circuit Description:
Sensor supply 4 of the engine control module (ECM) provides a 5 VDC supply to the accelerator pedal position sensor.

Component Location:
The accelerator pedal or lever position sensor is mounted to the accelerator pedal assembly. Refer to the OEM service manual.

Conditions for Running the Diagnostics:
This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes:
The Engine Control Module (ECM) detected the sensor supply 4 signal voltage was out of range high.

Action Taken When the Fault Code is Active:
The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails. The engine will only idle.

Conditions for Clearing the Fault Code:
1) To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.
2) The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
3) The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
4) For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
5) The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:
This fault code can be caused by a short circuit to a voltage source in the OEM harness or a short circuit to an actuator signal circuit that is greater than 5-VDC. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Causes:
1) Inactive fault codes
2) Faulty ECM
3) Short circuit
4) Faulty OEM harness

PACCAR PX-9 CM2350 (2013-17) Fault Code:2183 PID:SID 79 SPN:1072 FMI:4 Engine Brake Actuator Driver 1 Circuit – Voltage Below Normal or Shorted to Low Source
PACCAR PX-9 CM2350 (2013-17) Fault Code:2182 PID:2182 SPN:1072 FMI:3 Engine Brake Actuator Driver 1 Circuit – Voltage Above Normal or Shorted to High Source
PACCAR PX-9 CM2350 (2013-17) Fault Code:214 PID:175 SPN:175 FMI:0 Engine Oil Temperature – Data Valid But Above Normal Operating Range – Most Severe Level
PACCAR PX-9 CM2350 (2013-17) Fault Code:213 PID:175 SPN:175 FMI:4 Engine Oil Temperature Sensor 1 Circuit – Voltage Below Normal or Shorted to Low Source
PACCAR PX-9 CM2350 (2013-17) Fault Code:212 PID:175 SPN:175 FMI:3 Engine Oil Temperature Sensor 1 Circuit – Voltage Above Normal or Shorted to High Source
PACCAR PX-9 CM2350 (2013-17) Fault Code:1981 PID: SPN:3936 FMI:0 Aftertreatment Diesel Particulate Filter System – Data Valid But Above Normal Operational Range – Least Severe Level