Eaton Fuller Advantage (2017) Fault Code: 83 PID: SID 18 SPN: FMI: 14 Invalid Shift Lever Position: Special Instructions

Overview:
The Fuller Advantage transmission may be equipped with an analog shift control device. The Transmission Electronic Control Unit (TECU) supplies the analog Shift Control Device a 5-volt reference through OEM wiring. This voltage is reduced by resistive ladder circuitry in the shift device, based on the position the driver selects. The return voltage to the TECU indicates the position of the Shift Lever. Fault Code 83 indicates the TECU did not identify a Shift Lever position.

Detection:
The TECU monitors Shift Lever position by supplying voltage to the Shift Lever and measuring the returned voltage. When the return voltage received by the TECU does not match any known shift mode this fault code sets Active.

Conditions to Set Fault Code Active:
FMI 14 – Special Instructions: Selected lever position is invalid for 0.5 seconds or longer.

Fallback:
FMI 14
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission may not engage a gear from neutral.
• Transmission enters downshift-only mode.

Conditions to Set Fault Code Inactive:
FMI 14: TECU recognizes a valid Shift Lever position from the Shift Lever after 0.2 seconds.

Possible Causes:
FMI 14
1) Vehicle Analog Shift Device
– Internal failure
– Lever positioned between two modes
2) Eaton Cobra Shift Lever
– Internal failure
– Lever positioned between two modes

Eaton Fuller Advantage (2017) Fault Code: 81 PID: SPN: 780 FMI: 7 Gear Engagement Detected: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 81 PID: SID 47 SPN: FMI: 7 Gear Engagement Detected: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 76 PID: SPN: 639 FMI: 31 Neutral Coast Mode: Condition Exists
Eaton Fuller Advantage (2017) Fault Code: 76 PID: SPN: 639 FMI: 11 Neutral Coast Mode: FMI Unknown
Eaton Fuller Advantage (2017) Fault Code: 75 PID: SPN: 560 FMI: 14 Power Down in Gear: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 75 PID: SID 60 SPN: FMI: 14 Power Down in Gear: Special Instructions

Read more →

Eaton Fuller Advantage (2017) Fault Code: 84 PID: SPN: 751 FMI: 13 Shift Device Not Configured: Out of Calibration

Overview:
The Fuller Advantage transmission may be equipped with an analog Shift Control Device. The Transmission Electronic Control Unit (TECU) supplies the analog Shift Control Device a 5-volt reference through OEM wiring. This voltage is reduced by resistive ladder circuitry in the Shift Device, based on the position the driver selects. The return voltage to the TECU indicates the position of the Shift Lever. Fault Code 84 indicates that the TECU detected an incorrect Driver Interface Type configuration.

Detection:
The TECU determines the type of Shift Control Device the vehicle is equipped with during the initial power up. Fault Code 84 sets Active when the stored Driver Interface Type configuration in the TECU does not match the Shift Device on the vehicle, provided there are no low battery system fault codes set.

Conditions to Set Fault Code Active:
FMI 13 – Out of Calibration: The stored Driver Interface Type configuration file does not match the Shift Device on the vehicle.

Fallback:
FMI 13
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission will not engage a gear from neutral.

Conditions to Set Fault Code Inactive:
FMI 13: This fault code is never set Inactive. Fault Code 84 only sets in an Active state.

Possible Causes:
FMI 13
1) TECU
– Driver Interface Type configuration incorrect or unknown

Eaton Fuller Advantage (2017) Fault Code: 84 PID: SID 18 SPN: FMI: 13 Shift Device Not Configured: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 83 PID: SPN: 751 FMI: 14 Invalid Shift Lever Position: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 83 PID: SID 18 SPN: FMI: 14 Invalid Shift Lever Position: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 81 PID: SPN: 780 FMI: 7 Gear Engagement Detected: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 81 PID: SID 47 SPN: FMI: 7 Gear Engagement Detected: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 76 PID: SPN: 639 FMI: 31 Neutral Coast Mode: Condition Exists

Read more →

Eaton Fuller Advantage (2017) Fault Code: 84 PID: SID 18 SPN: FMI: 13 Shift Device Not Configured: Out of Calibration

Overview:
The Fuller Advantage transmission may be equipped with an analog Shift Control Device. The Transmission Electronic Control Unit (TECU) supplies the analog Shift Control Device a 5-volt reference through OEM wiring. This voltage is reduced by resistive ladder circuitry in the Shift Device, based on the position the driver selects. The return voltage to the TECU indicates the position of the Shift Lever. Fault Code 84 indicates that the TECU detected an incorrect Driver Interface Type configuration.

Detection:
The TECU determines the type of Shift Control Device the vehicle is equipped with during the initial power up. Fault Code 84 sets Active when the stored Driver Interface Type configuration in the TECU does not match the Shift Device on the vehicle, provided there are no low battery system fault codes set.

Conditions to Set Fault Code Active:
FMI 13 – Out of Calibration: The stored Driver Interface Type configuration file does not match the Shift Device on the vehicle.

Fallback:
FMI 13
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine may not crank.
• Transmission will not engage a gear from neutral.

Conditions to Set Fault Code Inactive:
FMI 13: This fault code is never set Inactive. Fault Code 84 only sets in an Active state.

Possible Causes:
FMI 13
1) TECU
– Driver Interface Type configuration incorrect or unknown

Eaton Fuller Advantage (2017) Fault Code: 83 PID: SPN: 751 FMI: 14 Invalid Shift Lever Position: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 83 PID: SID 18 SPN: FMI: 14 Invalid Shift Lever Position: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 81 PID: SPN: 780 FMI: 7 Gear Engagement Detected: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 81 PID: SID 47 SPN: FMI: 7 Gear Engagement Detected: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 76 PID: SPN: 639 FMI: 31 Neutral Coast Mode: Condition Exists
Eaton Fuller Advantage (2017) Fault Code: 76 PID: SPN: 639 FMI: 11 Neutral Coast Mode: FMI Unknown

Read more →

Eaton Fuller Advantage (2017) Fault Code: 85 PID: SPN: 751 FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device

Overview:
The Fuller Advantage transmission may be equipped with an Eaton Push Button Shift Control Device (PBSC) or J1939 Shift Control Device. At key on, the Transmission Electronic Control Unit (TECU) establishes communication with the Shift Control Device in preparation for vehicle operation. Fault Code 85 sets when the TECU receives a message from an incompatible Shift Control Device.

Detection:
The TECU determines the type of Shift Control Device the vehicle is equipped with during the initial power up. If the TECU determines the Shift Control Device is incorrect and there are no low battery system faults, this fault code sets Active.

Conditions to Set Fault Code Active:
FMI 12 – Bad Intelligent Device: TECU detects an incompatible Shift Control Device for 10 seconds.

Fallback:
FMI 12
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission will not engage a gear from neutral.
• Transmission will not attempt to shift out of current gear.

Conditions to Set Fault Code Inactive:
FMI 12: TECU recognizes a valid Shift Control Device.

Possible Causes:
FMI 12
• Shift Control Device
– Improper Shift Control Device installed on vehicle

Eaton Fuller Advantage (2017) Fault Code: 85 PID: SID 18 SPN: FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 84 PID: SPN: 751 FMI: 13 Shift Device Not Configured: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 84 PID: SID 18 SPN: FMI: 13 Shift Device Not Configured: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 83 PID: SPN: 751 FMI: 14 Invalid Shift Lever Position: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 83 PID: SID 18 SPN: FMI: 14 Invalid Shift Lever Position: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 81 PID: SPN: 780 FMI: 7 Gear Engagement Detected: Mechanical System Not Responding

Read more →

Eaton Fuller Advantage (2017) Fault Code: 85 PID: SID 18 SPN: FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device

Overview:
The Fuller Advantage transmission may be equipped with an Eaton Push Button Shift Control Device (PBSC) or J1939 Shift Control Device. At key on, the Transmission Electronic Control Unit (TECU) establishes communication with the Shift Control Device in preparation for vehicle operation. Fault Code 85 sets when the TECU receives a message from an incompatible Shift Control Device.

Detection:
The TECU determines the type of Shift Control Device the vehicle is equipped with during the initial power up. If the TECU determines the Shift Control Device is incorrect and there are no low battery system faults, this fault code sets Active.

Conditions to Set Fault Code Active:
FMI 12 – Bad Intelligent Device: TECU detects an incompatible Shift Control Device for 10 seconds.

Fallback:
FMI 12
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission will not engage a gear from neutral.
• Transmission will not attempt to shift out of current gear.

Conditions to Set Fault Code Inactive:
FMI 12: TECU recognizes a valid Shift Control Device.

Possible Causes:
FMI 12
• Shift Control Device
– Improper Shift Control Device installed on vehicle

Eaton Fuller Advantage (2017) Fault Code: 84 PID: SPN: 751 FMI: 13 Shift Device Not Configured: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 84 PID: SID 18 SPN: FMI: 13 Shift Device Not Configured: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 83 PID: SPN: 751 FMI: 14 Invalid Shift Lever Position: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 83 PID: SID 18 SPN: FMI: 14 Invalid Shift Lever Position: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 81 PID: SPN: 780 FMI: 7 Gear Engagement Detected: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 81 PID: SID 47 SPN: FMI: 7 Gear Engagement Detected: Mechanical System Not Responding

Read more →

Eaton Fuller Advantage (2017) Fault Code: 86 PID: SPN: TBD FMI: 2 High Integrity Link Gen2 ECA: Data Erratic

Overview:
The High Integrity Link (HIL) is a Controller Area Network (CAN) high-speed proprietary data link that communicates data between the Transmission Electronic Control Unit (TECU), Electronic Clutch Actuator (ECA), and if equipped, Eaton Push Button Shift Control (PBSC). The portion of the HIL that connects the TECU to the ECA is contained within the Transmission Harness. The portion of the HIL that connects the TECU to the PBSC is contained within the Vehicle Harness. Fault Code 86 indicates a loss of communication of the HIL, but is specific to systems that use a Gen2 ECA. Troubleshooting for this procedure is specific to the Gen2 ECA and associated harnesses.

Note: The troubleshooting procedure for Fault Code 16 may direct users to use this troubleshooting procedure if the vehicle is equipped with a Gen2 ECA, even if Fault Code 86 was not set by the transmission. This is because some transmission software versions do not set Fault Code 86.

Detection:
The TECU monitors communication with the Shift Control Device (if equipped) and the ECA over the HIL Link. If the TECU is unable to receive any messages from the other components on the HIL, Fault Code 86 sets Active.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU does not receive any messages over the HIL for more than 5 seconds.

Fallback:
FMI 2
• Transmission may not engage a gear from neutral.
• Once the transmission down shifts to the start gear, no up shifts occur as long as the fault code is Active.
• If equipped with an Eaton PBSC:
– “F” flashes in gear display.
– Service light flashes (if equipped).
• If equipped with an Eaton Cobra Shift Lever or OEM J1939 Shift Controller:
– “F” does not flash in gear display.
– Service lamp does not flash.

Conditions to Set Fault Code Inactive:
FMI 2: Communication between components is restored for 5 seconds.

Possible Causes:
FMI 2
1) HIL
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Missing terminating resistor
2) Transmission Harness
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Seal failure in 8-Way ECA Connector
– Loss of ignition voltage to ECA before power up
3) ECA
– Bent, spread, corroded or loose terminals
– Contamination in 2-Way ECA Connector
– Contamination in 8-Way ECA Connector
– Internal failure
4) Vehicle Batteries
– Internal failure
5) Vehicle Power and Ground Supply to ECA
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Seal failure on 2-Way ECA Connector
– Disconnected 2-Way ECA Connector
6) Vehicle Power and Ground Supply to TECU
– Corroded or loose power supply connections to TECU
7) TECU
– Internal failure
8) PBSC (if equipped)
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 86 PID: SID TBD SPN: FMI: 2 High Integrity Link Gen2 ECA: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 85 PID: SPN: 751 FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 85 PID: SID 18 SPN: FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 84 PID: SPN: 751 FMI: 13 Shift Device Not Configured: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 84 PID: SID 18 SPN: FMI: 13 Shift Device Not Configured: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 83 PID: SPN: 751 FMI: 14 Invalid Shift Lever Position: Special Instructions

Read more →

Eaton Fuller Advantage (2017) Fault Code: 86 PID: SID TBD SPN: FMI: 2 High Integrity Link Gen2 ECA: Data Erratic

Overview:
The High Integrity Link (HIL) is a Controller Area Network (CAN) high-speed proprietary data link that communicates data between the Transmission Electronic Control Unit (TECU), Electronic Clutch Actuator (ECA), and if equipped, Eaton Push Button Shift Control (PBSC). The portion of the HIL that connects the TECU to the ECA is contained within the Transmission Harness. The portion of the HIL that connects the TECU to the PBSC is contained within the Vehicle Harness. Fault Code 86 indicates a loss of communication of the HIL, but is specific to systems that use a Gen2 ECA. Troubleshooting for this procedure is specific to the Gen2 ECA and associated harnesses.

Note: The troubleshooting procedure for Fault Code 16 may direct users to use this troubleshooting procedure if the vehicle is equipped with a Gen2 ECA, even if Fault Code 86 was not set by the transmission. This is because some transmission software versions do not set Fault Code 86.

Detection:
The TECU monitors communication with the Shift Control Device (if equipped) and the ECA over the HIL Link. If the TECU is unable to receive any messages from the other components on the HIL, Fault Code 86 sets Active.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU does not receive any messages over the HIL for more than 5 seconds.

Fallback:
FMI 2
• Transmission may not engage a gear from neutral.
• Once the transmission down shifts to the start gear, no up shifts occur as long as the fault code is Active.
• If equipped with an Eaton PBSC:
– “F” flashes in gear display.
– Service light flashes (if equipped).
• If equipped with an Eaton Cobra Shift Lever or OEM J1939 Shift Controller:
– “F” does not flash in gear display.
– Service lamp does not flash.

Conditions to Set Fault Code Inactive:
FMI 2: Communication between components is restored for 5 seconds.

Possible Causes:
FMI 2
1) HIL
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Missing terminating resistor
2) Transmission Harness
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Seal failure in 8-Way ECA Connector
– Loss of ignition voltage to ECA before power up
3) ECA
– Bent, spread, corroded or loose terminals
– Contamination in 2-Way ECA Connector
– Contamination in 8-Way ECA Connector
– Internal failure
4) Vehicle Batteries
– Internal failure
5) Vehicle Power and Ground Supply to ECA
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Seal failure on 2-Way ECA Connector
– Disconnected 2-Way ECA Connector
6) Vehicle Power and Ground Supply to TECU
– Corroded or loose power supply connections to TECU
7) TECU
– Internal failure
8) PBSC (if equipped)
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 85 PID: SPN: 751 FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 85 PID: SID 18 SPN: FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 84 PID: SPN: 751 FMI: 13 Shift Device Not Configured: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 84 PID: SID 18 SPN: FMI: 13 Shift Device Not Configured: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 83 PID: SPN: 751 FMI: 14 Invalid Shift Lever Position: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 83 PID: SID 18 SPN: FMI: 14 Invalid Shift Lever Position: Special Instructions

Read more →

Eaton Fuller Advantage (2017) Fault Code: 89 PID: SPN: TBD FMI: 9 CAN ECA Message Gen2 ECA: Abnormal Update Rate

Overview:
The High Integrity Link (HIL) is a Controller Area Network (CAN) high-speed proprietary data link that communicates data between the Transmission Electronic Control Unit (TECU), Electronic Clutch Actuator (ECA), and if equipped, Eaton Push Button Shift Control (PBSC). The portion of the HIL that connects the TECU to the ECA is contained within the Transmission Harness. The portion of the HIL that connects the TECU to the PBSC is contained within the Vehicle Harness. Fault Code 89 indicates a loss of communication between the TECU and ECA, but is specific to systems that use a Gen2 ECA. Troubleshooting for this procedure is specific to the Gen2 ECA and associated harnesses.

Note: The troubleshooting procedure for Fault Code 19 may direct users to use this troubleshooting procedure if the vehicle is equipped with a Gen2 ECA, even if Fault Code 89 was not set by the transmission. This is because some transmission software versions do not set Fault Code 89.

Detection:
The TECU monitors communication with the ECA over the HIL. If the TECU loses communication with the ECA, Fault Code 89 sets Active.

Conditions to Set Fault Code Active:
FMI 9 – Abnormal Update Rate: TECU loses communication with the ECA for 2 seconds or longer.

Fallback:
FMI 9
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine cranks and starts.
• Transmission may not engage a gear from neutral.
• ECA may maintain the current clutch position using the clutch holding device.
• ECA may move the clutch to the last position commanded by the TECU.

Conditions to Set Fault Code Inactive:
FMI 9: TECU establishes communication with the ECA for 4 seconds.

Possible Causes:
FMI 9
1) Vehicle Power and Ground Supply to ECA
– Poor power or ground supply
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Seal failure on 2-Way ECA Connector
– Disconnected 2-Way ECA Connector
2) Vehicle Batteries
– Internal failure
3) Transmission Harness
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Seal failure in 8-Way ECA Connector
– Loss of ignition voltage to ECA before power up
4) ECA
– Bent, spread, corroded or loose terminals
– Contamination in 2-Way ECA Connector
– Contamination in 8-Way ECA Connector
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 89 PID: SID TBD SPN: FMI: 9 CAN ECA Message Gen2 ECA: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 86 PID: SPN: TBD FMI: 2 High Integrity Link Gen2 ECA: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 86 PID: SID TBD SPN: FMI: 2 High Integrity Link Gen2 ECA: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 85 PID: SPN: 751 FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 85 PID: SID 18 SPN: FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 84 PID: SPN: 751 FMI: 13 Shift Device Not Configured: Out of Calibration

Read more →

Eaton Fuller Advantage (2017) Fault Code: 89 PID: SID TBD SPN: FMI: 9 CAN ECA Message Gen2 ECA: Abnormal Update Rate

Overview:
The High Integrity Link (HIL) is a Controller Area Network (CAN) high-speed proprietary data link that communicates data between the Transmission Electronic Control Unit (TECU), Electronic Clutch Actuator (ECA), and if equipped, Eaton Push Button Shift Control (PBSC). The portion of the HIL that connects the TECU to the ECA is contained within the Transmission Harness. The portion of the HIL that connects the TECU to the PBSC is contained within the Vehicle Harness. Fault Code 89 indicates a loss of communication between the TECU and ECA, but is specific to systems that use a Gen2 ECA. Troubleshooting for this procedure is specific to the Gen2 ECA and associated harnesses.

Note: The troubleshooting procedure for Fault Code 19 may direct users to use this troubleshooting procedure if the vehicle is equipped with a Gen2 ECA, even if Fault Code 89 was not set by the transmission. This is because some transmission software versions do not set Fault Code 89.

Detection:
The TECU monitors communication with the ECA over the HIL. If the TECU loses communication with the ECA, Fault Code 89 sets Active.

Conditions to Set Fault Code Active:
FMI 9 – Abnormal Update Rate: TECU loses communication with the ECA for 2 seconds or longer.

Fallback:
FMI 9
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine cranks and starts.
• Transmission may not engage a gear from neutral.
• ECA may maintain the current clutch position using the clutch holding device.
• ECA may move the clutch to the last position commanded by the TECU.

Conditions to Set Fault Code Inactive:
FMI 9: TECU establishes communication with the ECA for 4 seconds.

Possible Causes:
FMI 9
1) Vehicle Power and Ground Supply to ECA
– Poor power or ground supply
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Seal failure on 2-Way ECA Connector
– Disconnected 2-Way ECA Connector
2) Vehicle Batteries
– Internal failure
3) Transmission Harness
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Seal failure in 8-Way ECA Connector
– Loss of ignition voltage to ECA before power up
4) ECA
– Bent, spread, corroded or loose terminals
– Contamination in 2-Way ECA Connector
– Contamination in 8-Way ECA Connector
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 86 PID: SPN: TBD FMI: 2 High Integrity Link Gen2 ECA: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 86 PID: SID TBD SPN: FMI: 2 High Integrity Link Gen2 ECA: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 85 PID: SPN: 751 FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 85 PID: SID 18 SPN: FMI: 12 Shift Control Device Incompatible: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 84 PID: SPN: 751 FMI: 13 Shift Device Not Configured: Out of Calibration
Eaton Fuller Advantage (2017) Fault Code: 84 PID: SID 18 SPN: FMI: 13 Shift Device Not Configured: Out of Calibration

Read more →

Eaton Fuller Advantage (2017) Fault Code: 94 PID: SPN: TBD FMI: 12 Electronic Clutch Actuator Gen2 ECA: Bad Intelligent Device

Overview:
The Fuller Advantage transmission equipped with an Electronic Clutch Actuator (ECA) that controls the position of the clutch assembly. Power and ground to the ECA are OEM-supplied through a 2-Way Connector directly connected to the vehicle batteries. The ECA is connected to the TECU by an 8-Way Connector that is part of the transmission harness. The ECA communicates with the TECU over the High Integrity Link (HIL) to change position, show faults or include other operation information. Fault Code 94 indicates that a failure has been detected by the ECA, but is specific to systems that use a Gen2 ECA. Troubleshooting for this procedure is specific to the Gen2 ECA and associated harnesses.

Note: The troubleshooting procedure for Fault Code 64 may direct users to use this troubleshooting procedure if the vehicle is equipped with a Gen2 ECA, even if Fault Code 94 was not set by the transmission. This is because some transmission software versions do not set Fault Code 94.

Detection:
The TECU monitors the ECA for excessive motor current, excessive motor temperature, incorrect motor position, improper battery or ignition voltage to the ECA, or various internal ECA malfunctions.

Conditions to Set Fault Code Active:
FMI 12 – Bad Intelligent Device: ECA detects an internal
failure for 1 second or longer.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• If the fault occurs at power up, engine cranks and starts, but TECU will not engage a gear.
• If the fault occurs while driving, ECA maintains current clutch position or moves to the last position commanded by the TECU. Transmission may continue to shift until vehicle is stopped.

Conditions to Set Fault Code Inactive:
FMI 12: No internal ECA failures are detected for 2 seconds.

Possible Causes:
FMI 2, 12
1) ECA Power Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) ECA
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 94 PID: SPN: TBD FMI: 7 Electronic Clutch Actuator Gen2 ECA: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 94 PID: SPN: TBD FMI: 2 Electronic Clutch Actuator Gen2 ECA: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 94 PID: TBH SPN: FMI: 12 Electronic Clutch Actuator Gen2 ECA: Bad Intelligent Device
Eaton Fuller Advantage (2017) Fault Code: 94 PID: TBH SPN: FMI: 7 Electronic Clutch Actuator Gen2 ECA: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 94 PID: TBH SPN: FMI: 2 Electronic Clutch Actuator Gen2 ECA: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 89 PID: SPN: TBD FMI: 9 CAN ECA Message Gen2 ECA: Abnormal Update Rate

Read more →