Skip to content Skip to side menu

Eaton

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 14 Start Enable Relay: Special Instructions

Overview:
Vehicles with an Fuller Advantage transmission are required to disable engine cranking when the transmission is in a non-neutral gear position. Some vehicles prevent non-neutral engine cranking through the use of a normally open Start Enable Relay actuated by the Transmission Electronic Control Unit (TECU) to interrupt power to the Starter. Other vehicles require the TECU to send a transmission engine crank enable message over the J1939 Data Link before the engine ECU will allow cranking. The Start Enable Relay circuit is supplied and wired by the OEM. For vehicles equipped with a physical Start Enable Relay circuit, the relay will only latch when the following three conditions exist:
• Driver Interface Device is in the neutral position.
• Transmission has confirmed that it is physically in neutral.
• Engine is not running.

Under these conditions the TECU supplies a voltage source and a ground path to the Start Enable Relay coil, latching the relay. The latched relay allows Engine-Starter engagement when the ignition key is turned to the crank position. If these conditions are not met, the TECU removes the voltage source and ground path to the Start Enable Relay, opening the relay and preventing engagement of the Starter. Fault Code 17 indicates that an electrical failure in the Start-Enable Relay circuit was detected. The fault will not set on vehicles that use J1939 messaging to enable engine cranking.

Detection:
This fault can only be detected on transmission systems that are configured for Start Enable Relay. When the ignition key is on, the engine is not running, and the Start Enable Relay coil is not latched, this fault can be detected.

Conditions to Set Fault Code Active:
FMI 14 – Special Instructions: TECU detects an engine start when the Start Enable Relay was not intentionally latched. This is typically an indication that the Start Enable Relay circuit is incorrectly wired or bypassed (jumped).

Fallback:
FMI 14:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• If the Start Enable Relay circuit is incorrectly wired or bypassed (jumped), the TECU may not be able to prevent the engine from cranking when the transmission is in a non-neutral position.

Conditions to Set Fault Code Inactive:
FMI 14: Start Enable Relay wiring issue is corrected and Start Enable Relay fault code is unlatched.

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 16 PID: SPN: 625 FMI: 2 High Integrity Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 16 PID: SID 248 SPN: FMI: 2 High Integrity Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 15 PID: SPN: 751 FMI: 9 HIL Shift Device Communication: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 15 PID: SID 18 SPN: FMI: 9 HIL Shift Device Communication: Abnormal Update Rate

Read more →

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High

Overview:
Vehicles with an Fuller Advantage transmission are required to disable engine cranking when the transmission is in a non-neutral gear position. Some vehicles prevent non-neutral engine cranking through the use of a normally open Start Enable Relay actuated by the Transmission Electronic Control Unit (TECU) to interrupt power to the Starter. Other vehicles require the TECU to send a transmission engine crank enable message over the J1939 Data Link before the engine ECU will allow cranking. The Start Enable Relay circuit is supplied and wired by the OEM. For vehicles equipped with a physical Start Enable Relay circuit, the relay will only latch when the following three conditions exist:
• Driver Interface Device is in the neutral position.
• Transmission has confirmed that it is physically in neutral.
• Engine is not running.

Under these conditions the TECU supplies a voltage source and a ground path to the Start Enable Relay coil, latching the relay. The latched relay allows Engine-Starter engagement when the ignition key is turned to the crank position. If these conditions are not met, the TECU removes the voltage source and ground path to the Start Enable Relay, opening the relay and preventing engagement of the Starter. Fault Code 17 indicates that an electrical failure in the Start-Enable Relay circuit was detected. The fault will not set on vehicles that use J1939 messaging to enable engine cranking.

Detection:
This fault can only be detected on transmission systems that are configured for Start Enable Relay. When the ignition key is on, the engine is not running, and the Start Enable Relay coil is not latched, this fault can be detected.

Conditions to Set Fault Code Active:
FMI 3 – Voltage Above Normal or Shorted High: TECU detects a short to voltage or an open circuit for at least 1 second.

Fallback:
FMI 3, 4:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine will not crank.

Conditions to Set Fault Code Inactive:
FMI 3, 4: An electrical short or open circuit is not detected for 2 seconds.

Eaton Fuller Advantage (2017) Fault Code: 16 PID: SPN: 625 FMI: 2 High Integrity Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 16 PID: SID 248 SPN: FMI: 2 High Integrity Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 15 PID: SPN: 751 FMI: 9 HIL Shift Device Communication: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 15 PID: SID 18 SPN: FMI: 9 HIL Shift Device Communication: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 14 Invalid Shift Lever Voltage: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 5 Invalid Shift Lever Voltage: Current Below Normal or open Circuit

Read more →

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low

Overview:
Vehicles with an Fuller Advantage transmission are required to disable engine cranking when the transmission is in a non-neutral gear position. Some vehicles prevent non-neutral engine cranking through the use of a normally open Start Enable Relay actuated by the Transmission Electronic Control Unit (TECU) to interrupt power to the Starter. Other vehicles require the TECU to send a transmission engine crank enable message over the J1939 Data Link before the engine ECU will allow cranking. The Start Enable Relay circuit is supplied and wired by the OEM. For vehicles equipped with a physical Start Enable Relay circuit, the relay will only latch when the following three conditions exist:
• Driver Interface Device is in the neutral position.
• Transmission has confirmed that it is physically in neutral.
• Engine is not running.

Under these conditions the TECU supplies a voltage source and a ground path to the Start Enable Relay coil, latching the relay. The latched relay allows Engine-Starter engagement when the ignition key is turned to the crank position. If these conditions are not met, the TECU removes the voltage source and ground path to the Start Enable Relay, opening the relay and preventing engagement of the Starter. Fault Code 17 indicates that an electrical failure in the Start-Enable Relay circuit was detected. The fault will not set on vehicles that use J1939 messaging to enable engine cranking.

Detection:
This fault can only be detected on transmission systems that are configured for Start Enable Relay. When the ignition key is on, the engine is not running, and the Start Enable Relay coil is not latched, this fault can be detected.

Conditions to Set Fault Code Active:
FMI 4 – Voltage Below Normal or Shorted Low: TECU detects a short to ground for at least 1 second.

Fallback:
FMI 3, 4:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine will not crank.

Conditions to Set Fault Code Inactive:
FMI 3, 4: An electrical short or open circuit is not detected for 2 seconds.

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 16 PID: SPN: 625 FMI: 2 High Integrity Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 16 PID: SID 248 SPN: FMI: 2 High Integrity Link: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 15 PID: SPN: 751 FMI: 9 HIL Shift Device Communication: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 15 PID: SID 18 SPN: FMI: 9 HIL Shift Device Communication: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 14 PID: SPN: 752 FMI: 14 Invalid Shift Lever Voltage: Special Instructions

Read more →

Eaton Fuller Advantage (2017) Fault Code: 19 PID: SPN: 520273 FMI: 9 CAN ECA Message: Abnormal Update Rate

Overview:
The High Integrity Link (HIL) is a Controller Area Network (CAN) high-speed proprietary data link that communicates data between the Transmission Electronic Control Unit (TECU), Electronic Clutch Actuator (ECA), and if equipped, Eaton Push Button Shift Control (PBSC). The portion of the HIL that connects the TECU to the ECA is contained within the Transmission Harness. The portion of the HIL that connects the TECU to the PBSC is contained within the Vehicle Harness. Fault Code 19 indicates a loss of communication between the TECU and ECA.

Detection:
The TECU monitors communication with the ECA over the HIL. If the TECU loses communication with the ECA, Fault Code 19 sets Active.

Conditions to Set Fault Code Active:
FMI 9 – Abnormal Update Rate: TECU loses communication with the ECA for 2 seconds or longer.

Fallback:
FMI 9
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine cranks and starts.
• Transmission may not engage a gear from neutral.
• ECA may maintain the current clutch position using the clutch holding device.
• ECA may move the clutch to the last position commanded by the TECU.

Conditions to Set Fault Code Inactive:
FMI 9: TECU establishes communication with the ECA for 4 seconds.

Possible Causes:
FMI 9
1) Vehicle Power and Ground Supply to ECA
– Poor power or ground supply
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Seal failure on 3-Way ECA Connector
– Disconnected 3-Way ECA Connector
2) Vehicle Batteries
– Internal failure
3) Transmission Harness
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Seal failure in 8-Way ECA Connector
– Loss of ignition voltage to ECA before power up
4) ECA
– Failed ECA software download
– Bent, spread, corroded or loose terminals
– Contamination in 3-Way ECA Connector
– Contamination in 8-Way ECA Connector
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 19 PID: SID 248 SPN: FMI: 9 CAN ECA Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 14 Start Enable Relay: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 14 Start Enable Relay: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low

Read more →

Eaton Fuller Advantage (2017) Fault Code: 19 PID: SID 248 SPN: FMI: 9 CAN ECA Message: Abnormal Update Rate

Overview:
The High Integrity Link (HIL) is a Controller Area Network (CAN) high-speed proprietary data link that communicates data between the Transmission Electronic Control Unit (TECU), Electronic Clutch Actuator (ECA), and if equipped, Eaton Push Button Shift Control (PBSC). The portion of the HIL that connects the TECU to the ECA is contained within the Transmission Harness. The portion of the HIL that connects the TECU to the PBSC is contained within the Vehicle Harness. Fault Code 19 indicates a loss of communication between the TECU and ECA.

Detection:
The TECU monitors communication with the ECA over the HIL. If the TECU loses communication with the ECA, Fault Code 19 sets Active.

Conditions to Set Fault Code Active:
FMI 9 – Abnormal Update Rate: TECU loses communication with the ECA for 2 seconds or longer.

Fallback:
FMI 9
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Engine cranks and starts.
• Transmission may not engage a gear from neutral.
• ECA may maintain the current clutch position using the clutch holding device.
• ECA may move the clutch to the last position commanded by the TECU.

Conditions to Set Fault Code Inactive:
FMI 9: TECU establishes communication with the ECA for 4 seconds.

Possible Causes:
FMI 9
1) Vehicle Power and Ground Supply to ECA
– Poor power or ground supply
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Seal failure on 3-Way ECA Connector
– Disconnected 3-Way ECA Connector
2) Vehicle Batteries
– Internal failure
3) Transmission Harness
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
– Seal failure in 8-Way ECA Connector
– Loss of ignition voltage to ECA before power up
4) ECA
– Failed ECA software download
– Bent, spread, corroded or loose terminals
– Contamination in 3-Way ECA Connector
– Contamination in 8-Way ECA Connector
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 14 Start Enable Relay: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 14 Start Enable Relay: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High

Read more →

Eaton Fuller Advantage (2017) Fault Code: 21 PID: 70 SPN: FMI: 14 Auto-Neutral Park Brake Switch: Special Instructions

Overview:
The Fuller Advantage transmission is equipped with an auto-neutral function. This function shifts the transmission to neutral when the vehicle is brought to a complete stop while the transmission is in gear and the park brake is set. Fault Code 21 indicates a problem with the Auto-Neutral Park Brake Switch circuit.

Detection:
The TECU has two options that can be configured depending on component setup. For a TECU configured for a Hard-Wired Park Brake Switch, this fault can be detected anytime the ignition key is on. For a TECU configured for a J1939 Park Brake Switch input, the fault can be detected anytime the J1939 communicates to the TECU from a chassis module (e.g., Cab Controller, Engine, etc).

Conditions to Set Fault Code Active:
FMI 14 – Special Instructions: Park Brake Switch is set and one of the following are true:
• Vehicle is moving 11 MPH or greater for more than 9 seconds.
• Hard-wired Park Brake Switch and J1939 Park Brake Switch values do not match for more than 3 seconds.

Note: The fault can also set anytime the Park Brake Switch status remains released for five consecutive power-up and power-down cycles.

Fallback:
FMI 14
• Remote Throttle and Split Shaft PTO (if equipped) may be inoperative if the TECU cannot determine if the park brake is set.

Conditions to Set Fault Code Inactive:
FMI 14: Park Brake Switch circuit operates normally for 6 seconds or after a power cycle.

Possible Causes:
FMI 14
1) Park Brake Switch
– Normally open park brake switch installed on chassis (Normally closed is required)
– Internal failure
2) Park Brake Switch Configuration
– Incorrect configuration setting
3) Vehicle Harness
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
4) J1939 Data Link
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
5) Operator Influence
– Not setting Park Brake Switch

Eaton Fuller Advantage (2017) Fault Code: 19 PID: SPN: 520273 FMI: 9 CAN ECA Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 19 PID: SID 248 SPN: FMI: 9 CAN ECA Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 14 Start Enable Relay: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SID 237 SPN: FMI: 14 Start Enable Relay: Special Instructions

Read more →

Eaton Fuller Advantage (2017) Fault Code: 21 PID: SPN: 70 FMI: 14 Auto-Neutral Park Brake Switch: Special Instructions

Overview:
The Fuller Advantage transmission is equipped with an auto-neutral function. This function shifts the transmission to neutral when the vehicle is brought to a complete stop while the transmission is in gear and the park brake is set. Fault Code 21 indicates a problem with the Auto-Neutral Park Brake Switch circuit.

Detection:
The TECU has two options that can be configured depending on component setup. For a TECU configured for a Hard-Wired Park Brake Switch, this fault can be detected anytime the ignition key is on. For a TECU configured for a J1939 Park Brake Switch input, the fault can be detected anytime the J1939 communicates to the TECU from a chassis module (e.g., Cab Controller, Engine, etc).

Conditions to Set Fault Code Active:
FMI 14 – Special Instructions: Park Brake Switch is set and one of the following are true:
• Vehicle is moving 11 MPH or greater for more than 9 seconds.
• Hard-wired Park Brake Switch and J1939 Park Brake Switch values do not match for more than 3 seconds.

Note: The fault can also set anytime the Park Brake Switch status remains released for five consecutive power-up and power-down cycles.

Fallback:
FMI 14
• Remote Throttle and Split Shaft PTO (if equipped) may be inoperative if the TECU cannot determine if the park brake is set.

Conditions to Set Fault Code Inactive:
FMI 14: Park Brake Switch circuit operates normally for 6 seconds or after a power cycle.

Possible Causes:
FMI 14
1) Park Brake Switch
– Normally open park brake switch installed on chassis (Normally closed is required)
– Internal failure
2) Park Brake Switch Configuration
– Incorrect configuration setting
3) Vehicle Harness
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
4) J1939 Data Link
– Wiring shorted to ground, shorted to power or open
– Bent, spread, corroded or loose terminals
5) Operator Influence
– Not setting Park Brake Switch

Eaton Fuller Advantage (2017) Fault Code: 21 PID: 70 SPN: FMI: 14 Auto-Neutral Park Brake Switch: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 19 PID: SPN: 520273 FMI: 9 CAN ECA Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 19 PID: SID 248 SPN: FMI: 9 CAN ECA Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 14 Start Enable Relay: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 4 Start Enable Relay: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 3 Start Enable Relay: Voltage Above Normal or Shorted High

Read more →

Eaton Fuller Advantage (2017) Fault Code: 22 PID: SPN: 563 FMI: 14 ABS CAN Message: Special Instructions

Overview:
The Fuller Advantage transmission is equipped with Hill Start Aid (HSA) which prevents roll-back and roll-forward while launching on grades that are 1% and greater. The HSA holds for 3 seconds using vehicle foundation wheel brakes. The Transmission Electronic Control Unit (TECU) and ABS Module communicate over the J1939 Data Link and control the HSA function. Fault Code 22 sets if the TECU loses communication with the ABS or the ABS communicates that the HSA is not available.

Detection:
The TECU communicates with the ABS module over the J1939 Data Link. If communication is lost with the ABS module or the ABS module broadcasts a message indicating HSA is not available, this fault sets Active.

Conditions to Set Fault Code Active:
FMI 14 – Special Instructions: TECU receives a message from the ABS Module, over the J1939 Data Link, that the HSA function is not available.

Fallback:
All FMIs
• Hill Start Aid is inoperative.

Conditions to Set Fault Code Inactive:
All FMIs: TECU establishes communication with the ABS module and the ABS module communicates that HSA is available.

Possible Causes:
FMI 14
1) ABS System
– ABS component or system fault code
– ABS module does not support or is not configured for HSA
– ABS module internal failure
2) HSA Disable Switch
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 22 PID: SPN: 563 FMI: 9 ABS CAN Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 22 PID: SID 254 SPN: FMI: 14 ABS CAN Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 22 PID: SID 254 SPN: FMI: 9 ABS CAN Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 21 PID: SPN: 70 FMI: 14 Auto-Neutral Park Brake Switch: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 21 PID: 70 SPN: FMI: 14 Auto-Neutral Park Brake Switch: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 19 PID: SPN: 520273 FMI: 9 CAN ECA Message: Abnormal Update Rate

Read more →

Eaton Fuller Advantage (2017) Fault Code: 22 PID: SPN: 563 FMI: 9 ABS CAN Message: Abnormal Update Rate

Overview:
The Fuller Advantage transmission is equipped with Hill Start Aid (HSA) which prevents roll-back and roll-forward while launching on grades that are 1% and greater. The HSA holds for 3 seconds using vehicle foundation wheel brakes. The Transmission Electronic Control Unit (TECU) and ABS Module communicate over the J1939 Data Link and control the HSA function. Fault Code 22 sets if the TECU loses communication with the ABS or the ABS communicates that the HSA is not available.

Detection:
The TECU communicates with the ABS module over the J1939 Data Link. If communication is lost with the ABS module or the ABS module broadcasts a message indicating HSA is not available, this fault sets Active.

Conditions to Set Fault Code Active
FMI 9 – Abnormal Update Rate: TECU detects a loss of communication with the ABS Module over the J1939 Data Link for 5 seconds while other J1939 devices are still communicating with the TECU.

Fallback:
All FMIs
• Hill Start Aid is inoperative

Conditions to Set Fault Code Inactive:
All FMIs: TECU establishes communication with the ABS module and the ABS module communicates that HSA is available.

Possible Causes:
FMI 9
1) J1939 Data Link
– J1939 Data Link damage between TECU and ABS module
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open

Eaton Fuller Advantage (2017) Fault Code: 22 PID: SID 254 SPN: FMI: 14 ABS CAN Message: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 22 PID: SID 254 SPN: FMI: 9 ABS CAN Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 21 PID: SPN: 70 FMI: 14 Auto-Neutral Park Brake Switch: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 21 PID: 70 SPN: FMI: 14 Auto-Neutral Park Brake Switch: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 19 PID: SPN: 520273 FMI: 9 CAN ECA Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 19 PID: SID 248 SPN: FMI: 9 CAN ECA Message: Abnormal Update Rate

Read more →

Eaton Fuller Advantage (2017) Fault Code: 22 PID: SID 254 SPN: FMI: 14 ABS CAN Message: Special Instructions

Overview:
The Fuller Advantage transmission is equipped with Hill Start Aid (HSA) which prevents roll-back and roll-forward while launching on grades that are 1% and greater. The HSA holds for 3 seconds using vehicle foundation wheel brakes. The Transmission Electronic Control Unit (TECU) and ABS Module communicate over the J1939 Data Link and control the HSA function. Fault Code 22 sets if the TECU loses communication with the ABS or the ABS communicates that the HSA is not available.

Detection:
The TECU communicates with the ABS module over the J1939 Data Link. If communication is lost with the ABS module or the ABS module broadcasts a message indicating HSA is not available, this fault sets Active.

Conditions to Set Fault Code Active:
FMI 14 – Special Instructions: TECU receives a message from the ABS Module, over the J1939 Data Link, that the HSA function is not available.

Fallback:
All FMIs
• Hill Start Aid is inoperative.

Conditions to Set Fault Code Inactive:
All FMIs: TECU establishes communication with the ABS module and the ABS module communicates that HSA is available.

Possible Causes:
FMI 14
1) ABS System
– ABS component or system fault code
– ABS module does not support or is not configured for HSA
– ABS module internal failure
2) HSA Disable Switch
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 22 PID: SID 254 SPN: FMI: 9 ABS CAN Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 21 PID: SPN: 70 FMI: 14 Auto-Neutral Park Brake Switch: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 21 PID: 70 SPN: FMI: 14 Auto-Neutral Park Brake Switch: Special Instructions
Eaton Fuller Advantage (2017) Fault Code: 19 PID: SPN: 520273 FMI: 9 CAN ECA Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 19 PID: SID 248 SPN: FMI: 9 CAN ECA Message: Abnormal Update Rate
Eaton Fuller Advantage (2017) Fault Code: 17 PID: SPN: 1321 FMI: 14 Start Enable Relay: Special Instructions

Read more →