Detroit Diesel
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 520287 FMI 13 (MCM) Software Reset Due to Internal Monitoring
NOTE: Reprogram Motor Control Module (MCM) with the latest software version.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 520287 FMI 7 (MCM) Software Reset Due to Hardware Issue in the Monitor Control Module
NOTE: Internal Motor Control Module (MCM) hardware defect. Replace (Engine ECM).
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 520296 FMI 13 (MCM) Exhaust Gas Recirculation Valve Actuator Error
DESCRIPTION:
Exhaust gas recirculatin (EGR) valve actuator, error.
MONITORED PARAMETER:
EGR valve actuator.
TYPICAL ENABLING CONDITIONS:
EGR valve actuator internal self test at start up.
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Continuous when enabling conditiosn met.
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
Derate 25%
NOTE: If code 168-1 present, fix that first.
PROBABLE CAUSES:
1. Cranking and/or charging system of the truck.
2. EGR valve actuator pull rod.
3. Inspect for exhaust leaks around the EGR valve, repair as needed.
4. EGR valve failure.
5. Wiring between EGR valve and ECM.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 520296 FMI 19 (MCM) Exhaust Gas Recirculation Valve Actuator, Communication Error
DESCRIPTION:
Exhaust gas recirculation (EGR) valve actuator, intenal test running.
MONITORED PARAMETER:
EGR valve actuator.
TYPICAL ENABLING CONDITIONS:
EGR valve actuator internal self test at start up.
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
TYPICAL DURATION:
Two seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
Derate 25%
NOTE: If code 168-1 present, fix that first.
PROBABLE CAUSES:
1. Cranking and/or charging system of the truck.
2. EGR valve actuator pull rod.
3. Inspect for exhaust leaks around the EGR valve, repair as needed.
4. EGR valve failure.
5. Wiring between EGR valve and ECM.
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 520323 FMI 3 (ACM) High Side Digital Output Circuit Failed High
DESCRIPTION:
High side digital output circuit failed high.
MONITORED PARAMETER:
DEF dosing unit voltage.
TYPICAL ENABLING CONDITIONS:
DEF dosing enabled.
MONITOR SEQUENCE:
None
EXECUTION FREQUENCY:
Continuous when enabling conditions met.
TYPICAL DURATION:
Five seconds
DASH LAMPS:
1. MIL
2. CEL
ENGINE REACTION:
Derate 25%
VERIFICATION:
Parked regen
PROBABLE CAUSES:
1. DEF Dosing unit connector.
2. Wiring between the DEF dosing unit and ECM.