Skip to content Skip to side menu

Detroit Diesel

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available

DESCRIPTION:
Selective catalyst reduction (SCR) inlet NOx sensor signal not available.

MONITORED PARAMETER:
SCR inlet NOx sensor signal.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
Two seconds

DASH LAMPS:
MIL

VERIFICATION:
Engine Idle: One minute.

NOTE: If fault occurred during high idle regeneration, clear fault and release vehicle.

NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer.

PROBABLE CAUSES:
1. SCR inlet NOx sensor.
2. SCR inlet NOx sensor connector/harness.
3. ACM2 (engine computer) failure.

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 10 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Rationality Error
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3187 FMI 9 (CPC) CPC has Lost Communication with the DT12 Shift Stalk Lever
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3064 FMI 13 (MCM) MCM Needs to be Reprogrammed

Read more →

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Rationality Error

DESCRIPTION:
This fault code sets when the difference between the expected NOX ppm and the actual NOx ppm is greater than 200 ppm.

MONITORED PARAMETER:
Aftertreatment inlet NOx sensor.

TYPICAL ENABLING CONDITIONS:
General Enabling Conditions: Engine is not in regeneration and operating at high speed and loads.

Engine Parameter:
1. Engine Speed (rpm):
– Min: 1350
– Max 1600

2. Torque (Nm):
– Min: 1100
– Max: 1500

3. Battery Voltage (Volts):
– Min: 11.08

4. Engine Coolant Outlet Temperature:
– Min: 70°C (158°F)

5. Ambient Temperature
– Min: -8°C (17.6°F)

6. Barometric Pressure (mbar):
– Min: 755

7. Time Since DPF Regeneration (min.):
– Min: 15

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
150 seconds (2 cycle)

DASH LAMPS:
MIL

ENGINE REACTION:
None

VERIFICATION:
1. Warm up the engine and ensure engine is not in regeneration mode.
2. Drive a fully loaded trailer on highway and maintain above enabling conditions for 150 seconds.

NOTE: If any other EGR codes are active, fix those first.

PROBABLE CAUSES:
1. Inspect the entire air inlet system, charge air cooler, and EGR piping/hoses.
2. Check for failed injector.
3. Check the aftertreatment system for leaks/damage.
4. Perform a high idle regeneration.

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3187 FMI 9 (CPC) CPC has Lost Communication with the DT12 Shift Stalk Lever
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3064 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3058 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3058 FMI 10 (MCM) Exhaust Gas Recirculation Valve Actuator Slow Response
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3058 FMI 9 (MCM) Exhaust Gas Recirculation Flow Target Error (Low Flow)
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3057 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor – Error

Read more →

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 21 (ACM) SCR NOx Inlet Sensor Drift Low

DESCRIPTION:
Selective catalyst reduction (SCR) inlet NOx sensor – drift (low box).

MONITORED PARAMETER:
Engine out NOx.

TYPICAL ENABLING CONDITIONS:
1. Exhaust gas recirculation (EGR) mass flow greater than .08 kg/s.
2. Engine speed is between 1450-1900 rpm.
3. Engine torque is between 1400-2100 N·m (1033 to 1549 lb·ft).
4. Battery voltage greater than 11 vDC.
5. Coolant temperature greater than 65°C (149°F).
6. Ambient temperature greater than -8°C (17.6°F) ambient.
7. Barometric pressure greater than 755 mbar.
8. Engine is not in regeneration mode.

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
1.2 seconds

DASH LAMPS:
MIL

ENGINE REACTION:
None

VERIFICATION:
1. Warm up engine such that coolant temperature greater than 65°C (149°F).
2. Ensure engine is not in regeneration mode.
3. Ensure ambient temperature greater than -8°C (18°F) barometric pressure greater than 755 mbar.

NOTE: If any other EGR codes are active, fix those first.

PROBABLE CAUSES:
1. Inspect the entire air inlet system, charge air cooler, and EGR piping/hoses.
2. Check for failed injector.
3. Check the aftertreatment system for leaks/damage.
4. Perform a high idle regeneration.

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 10 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Rationality Error
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3187 FMI 9 (CPC) CPC has Lost Communication with the DT12 Shift Stalk Lever

Read more →

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction (SCR) Inlet NOx Sensor – Drift (Low Box)

DESCRIPTION:
Selective Catalyst Reduction (SCR) inlet NOx sensor – Drift (Low Box).

MONITORED PARAMETER:
Engine out NOx.

TYPICAL ENABLING CONDITIONS:
1. EGR Mass Flow greater than .08 kg/s.
2. Engine Speed 1450-1900 rpm.
3. Engine Torque 1400-2100 N·m.
4. Battery Voltage greater than 11 vDC .
5. Coolant Temperature greater than 65°C (149°F).
6. Ambient Temperature greater than -8°C (18°F) Ambient.
7. Barometric Pressure greater than 755 mbar.
8. Engine not in regeneration mode.

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
1.2 seconds

DASH LAMPS:
MIL

ENGINE REACTION:
None

VERIFICATION:
1. Warm up engine such that coolant temperature greater than 65°C (149°F).
2. Ensure engine is not in regeneration mode.
3. Ensure ambient temperature greater than -8°C (18°F) barometric pressure greater than 755 mbar.

NOTE: If any other EGR codes are active, fix those first.

PROBABLE CAUSES:
1. Inspect the entire air inlet system, charge air cooler, and EGR piping/hoses.
2. Check for failed injector.
3. Check the aftertreatment system for leaks/damage.
4. Perform a high idle regeneration.

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 21 (ACM) SCR NOx Inlet Sensor Drift Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 10 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Rationality Error

Read more →

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High

DESCRIPTION:
This code sets when there is a short to power on the SCR NOx inlet circuit between the sensor and the CPU.

MONITORED PARAMETER:
SCR inlet NOx sensor.

TYPICAL ENABLING CONDITIONS:
Dewpoint enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
None

VERIFICATION:
Parked regen

NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer.

PROBABLE CAUSES:
SCR inlet NOx sensor.

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Rationality Error
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3187 FMI 9 (CPC) CPC has Lost Communication with the DT12 Shift Stalk Lever
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3064 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3058 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3058 FMI 10 (MCM) Exhaust Gas Recirculation Valve Actuator Slow Response
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3058 FMI 9 (MCM) Exhaust Gas Recirculation Flow Target Error (Low Flow)

Read more →

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low

DESCRIPTION:
This code sets when there is a short to ground on the SCR NOx inlet circuit between the sensor and the CPU.

MONITORED PARAMETER:
SCR inlet NOx sensor.

TYPICAL ENABLING CONDITIONS:
Dewpoint enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
None

VERIFICATION:
Parked regen

NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer.

PROBABLE CAUSES:
SCR inlet NOx sensor.

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Rationality Error
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3187 FMI 9 (CPC) CPC has Lost Communication with the DT12 Shift Stalk Lever
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3064 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3058 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3058 FMI 10 (MCM) Exhaust Gas Recirculation Valve Actuator Slow Response

Read more →

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3223 FMI 7 (ACM) NOx RAW Sensor Not Ready After Dewpoint Enable Check

DESCRIPTION:
NOx inlet sensor failure to active.

MONITORED PARAMETER:
NOx inlet sensor.

TYPICAL ENABLING CONDITIONS:
NOx raw count.

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
Always on

DASH LAMPS:
MIL

ENGINE REACTION:
None

VERIFICATION:
Once engine is at standard operating temperature, drive at highway speed with loaded trailer above 1130 rpm continuously for twenty minutes.

NOTE: If codes 5357-16 or 5357-18 present, fix those first.

PROBABLE CAUSES:
1. Perform a stationary regen.
2. SCR inlet NOx sensor.

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction (SCR) Inlet NOx Sensor – Drift (Low Box)
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 21 (ACM) SCR NOx Inlet Sensor Drift Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 10 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High

Read more →

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3226 FMI 13 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Signal Not Available

DESCRIPTION:
Selective catalyst reduction (SCR) outlet NOx sensor signal not available.

MONITORED PARAMETER:
SCR outlet NOx sensor signal.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
Two seconds

DASH LAMPS:
MIL

VERIFICATION:
Engine Idle: One minute.

NOTE: If fault occurred during high idle regeneration, clear fault and release vehicle.

NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer.

PROBABLE CAUSES:
1. SCR outlet NOx sensor.
2. SCR outlet NOx sensor connector/harness.
3. ACM2 (engine computer) failure.

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3226 FMI 4 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3226 FMI 3 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed High
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3223 FMI 7 (ACM) NOx RAW Sensor Not Ready After Dewpoint Enable Check
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction (SCR) Inlet NOx Sensor – Drift (Low Box)
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 21 (ACM) SCR NOx Inlet Sensor Drift Low

Read more →

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift

DESCRIPTION:
Outlet NOx sensor is drifted.

MONITORED PARAMETER:
1. Selective catalyst reduction (SCR) outlet NOx.
2. Engine speed between 1000 to 2000 rpm.
3. Engine load between 25 to 100%.

TYPICAL ENABLING CONDITIONS:
1. SCR temperature greater than 390°C (734°F) for 10 seconds.
2. Inlet NOx to outlet NOx deviation greater than 200 ppm.

MONITOR SEQUENCE:
Once per drive cycle.

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
20 seconds

DASH LAMPS:
None

ENGINE REACTION:
Dosing is disabled

VERIFICATION:
Parked regeneration

NOTE: If any other EGR codes are active, fix those first.

PROBABLE CAUSES:
1. Check the aftertreatment system for leaks/damage.
2. Perform a high idle regeneration with the metering valve or dosing unit disconnected.

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3223 FMI 7 (ACM) NOx RAW Sensor Not Ready After Dewpoint Enable Check
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction (SCR) Inlet NOx Sensor – Drift (Low Box)
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 21 (ACM) SCR NOx Inlet Sensor Drift Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 10 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low

Read more →

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3226 FMI 20 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift Low

DESCRIPTION:
Selective catalyst reduction (SCR) outlet NOx sensor – drift low.

MONITORED PARAMETER:
Engine out NOx.

TYPICAL ENABLING CONDITIONS:
The following must be true for greater than 30 seconds:
1. Fuel mass is 0.
2. Diesel particulate filter (DPF) outlet temperature greater than 200 °C (392°F).
3. Battery voltage greater than 10V DC.
4. Engine Speed 500 to 2100 rpm.

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
Five seconds

DASH LAMPS:
MIL

ENGINE REACTION:
None

VERIFICATION:
Parked regeneration

Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3226 FMI 13 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Signal Not Available
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3226 FMI 4 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed Low
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3226 FMI 3 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed High
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3223 FMI 7 (ACM) NOx RAW Sensor Not Ready After Dewpoint Enable Check
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction (SCR) Inlet NOx Sensor – Drift (Low Box)

Read more →