Skip to content Skip to side menu

Detroit Diesel

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift (Low Box)

DESCRIPTION:
Selective Catalyst Reduction (SCR) Inlet NOx Sensor – Drift (Low Box).

MONITORED PARAMETER:
Engine out NOx.

TYPICAL ENABLING CONDITIONS:
1. Exhaust Gas Recirculation (EGR) mass flow greater than .08 kg/s.
2. Engine speed is between 1450-1900 RPM.
3. Engine torque is between 1400-2100 N·m (1033 to 1549 lb·ft).
4. Battery voltage greater than 11 vDC.
5. Coolant temperature greater than 65°C (149°F).
6. Ambient temperature greater than -8°C (17.6°F) ambient.
7. Barometric pressure greater than 755 mbar.
8. Engine is not in regeneration mode.

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
1.2 seconds

DASH LAMPS:
MIL

ENGINE REACTION:
None

VERIFICATION:
1. Warm up engine such that coolant temperature greater than 65°C (149°F).
2. Ensure engine is not in regeneration mode.
3. Ensure ambient temperature greater than -8°C (18°F) barometric pressure greater than 755 mbar.

NOTE: If any other EGR codes are active, fix those first.

PROBABLE CAUSES:
1. Inspect the entire air inlet system, charge air cooler, and EGR piping/hoses.
2. Check for failed injector.
3. Check the aftertreatment system for leaks/damage.
4. Perform a high idle regeneration

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 2 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3064 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3058 FMI 13 (MCM) MCM Needs to be Reprogrammed

Read more →

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High

DESCRIPTION:
This code sets when there is a short to power on the SCR NOx inlet circuit between the sensor and the CPU.

MONITORED PARAMETER:
SCR inlet NOx sensor.

TYPICAL ENABLING CONDITIONS:
Dewpoint enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
None

VERIFICATION:
Parked regen

NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer.

PROBABLE CAUSES:
SCR inlet NOx sensor.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 2 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3064 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3058 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3057 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor – Error
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3056 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor – Error
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3031 FMI 4 (ACM) Diesel Exhaust Fluid Tank Temperature Sensor Circuit Failed Low

Read more →

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low

DESCRIPTION:
This code sets when there is a short to ground on the SCR NOx inlet circuit between the sensor and the CPU.

MONITORED PARAMETER:
SCR inlet NOx sensor.

TYPICAL ENABLING CONDITIONS:
Dewpoint enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
None

VERIFICATION:
Parked regen

NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer.

PROBABLE CAUSES:
SCR inlet NOx sensor.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 2 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3064 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3058 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3057 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor – Error
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3056 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor – Error

Read more →

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 13 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Signal Not Available

DESCRIPTION:
Selective catalyst reduction (SCR) outlet NOx sensor signal not available.

MONITORED PARAMETER:
SCR outlet NOx sensor signal.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
Two seconds

DASH LAMPS:
MIL

VERIFICATION:
Engine Idle: One minute.

NOTE: If fault occurred during high idle regeneration, clear fault and release vehicle.

NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer.

PROBABLE CAUSES:
1. SCR outlet NOx sensor.
2. SCR outlet NOx sensor connector/harness.
3. ACM2 (engine computer) failure.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 4 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 3 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift (Low Box)
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low

Read more →

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift

DESCRIPTION:
Outlet NOx sensor is drifted.

MONITORED PARAMETER:
1. Selective catalyst reduction (SCR) outlet NOx.
2. Engine speed between 1000 to 2000 rpm.
3. Engine load between 25 to 100%.

TYPICAL ENABLING CONDITIONS:
1. SCR temperature greater than 390°C (734°F) for 10 seconds.
2. Inlet NOx to outlet NOx deviation greater than 200 ppm.

MONITOR SEQUENCE:
Once per drive cycle.

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
20 seconds

DASH LAMPS:
None

ENGINE REACTION:
Dosing is disabled.

VERIFICATION:
Parked regeneration

NOTE: If any other EGR codes are active, fix those first.

PROBABLE CAUSES:
1. Check the aftertreatment system for leaks/damage.
2. Perform a high idle regeneration with the metering valve or dosing unit disconnected.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift (Low Box)
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 2 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3064 FMI 13 (MCM) MCM Needs to be Reprogrammed

Read more →

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 21 (ACM) NOx Outlet Sensor Drift High

DESCRIPTION:
Outlet NOx sensor drifted high.

MONITORED PARAMETER:
Selective catalyst reduction (SCR) outlet NOx.

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
Two seconds

DASH LAMPS:
MIL

ENGINE REACTION:
None

VERIFICATION:
Parked regeneration

NOTE: If any other EGR codes are active, fix those first.

PROBABLE CAUSES:
1. Check the aftertreatment system for leaks/damage.
2. Perform a high idle regeneration with the metering valve or dosing unit disconnected.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 13 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Signal Not Available
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 4 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 3 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift (Low Box)
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available

Read more →

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 3 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed High

DESCRIPTION:
This code sets when there is a short to power on the SCR outlet NOx circuit between the sensor and CPU.

MONITORED PARAMETER:
SCR Outlet NOx sensor.

TYPICAL ENABLING CONDITIONS:
Dewpoint enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
None

VERIFICATION:
Parked regen

NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer.

PROBABLE CAUSES:
SCR outlet NOx sensor.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift (Low Box)
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 2 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift

Read more →

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 4 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed Low

DESCRIPTION:
This code sets when there is a short to ground on the SCR outlet NOx circuit between the sensor and CPU.

MONITORED PARAMETER:
SCR outlet NOx sensor.

TYPICAL ENABLING CONDITIONS:
Dewpoint enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
None

VERIFICATION:
Parked regen

NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer.

PROBABLE CAUSES:
SCR outlet NOx sensor.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 3 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift (Low Box)
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 13 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Signal Not Available
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High

Read more →

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3236 FMI 13 (ACM) Exhaust Mass Signal Not Available via Controller are Network

NOTE: Please see the step by step troubleshooting procedures for this specific code.

NOTE: If any engine ECMs have been programmed recently, clear codes and release vehicle to customer.

NOTE: Otherwise, clear codes, turn key off for 5 minutes, and re-start. If it comes back, use 625-9 to troubleshoot.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 21 (ACM) NOx Outlet Sensor Drift High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 13 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Signal Not Available
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 4 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 3 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift (Low Box)

Read more →

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3242 FMI 20 (ACM) Diesel Oxidation Catalyst Temperature Drift – Inlet High or Outlet Low

DESCRIPTION:
70°C (126°F) difference during non-regeneration mode.

MONITORED PARAMETER:
Diesel oxidation catalyst (DOC) inlet temperature vs. DOC outlet temperature.

TYPICAL ENABLING CONDITIONS:
1. Coolant temperature greater than 60°C (140°F).
2. Regen not active in the last five minutes.

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
One minute

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
Regen inhibit and 10% engine derate.

VERIFICATION:
Low temperature regen.

PROBABLE CAUSES:
1. Compare DOC inlet, DOC outlet, and DPF outlet. They should be within 45 degrees of each other.
2. DOC inlet temperature sensor.
3. DOC inlet temperature sensor connector/harness.
4. DOC outlet temperature sensor.
5. DOC outlet temperature sensor connector/harness.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3242 FMI 8 (ACM) Diesel Oxidation Catalyst Inlet Temperature – Signal Spike
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3242 FMI 4 (ACM) Diesel Oxidation Catalyst Inlet Temperature Sensor Failed Low
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3242 FMI 3 (ACM) Diesel Oxidation Catalyst Inlet Temperature Sensor Circuit Failed High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3236 FMI 13 (ACM) Exhaust Mass Signal Not Available via Controller are Network
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 21 (ACM) NOx Outlet Sensor Drift High
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3226 FMI 13 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Signal Not Available

Read more →