Skip to content

Telegram : @Diezel365

Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3511 FMI 3 (MCM) 3V Sensor Supply Bank 1 Circuit Failed High

DESCRIPTION:
3V sensor supply bank 1 circuit high voltage detected.

MONITORED PARAMETER:
Motor Control Module (MCM) 3V internal power supply.

TYPICAL ENABLING CONDITIONS:
Circuit voltage greater than 3.2 Volts.

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Always enabled

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
None

VERIFICATION:
Engine Idle (One minute).

PROBABLE CAUSES:
Short to power on one of the following from the main 120-pin ECM connector:
1. Pin 29 – DOC outlet temperature sensor.
2. Pin 88 – DOC inlet temperature sensor, DOC outlet temperature sensor, DPF inlet temperature sensor, DPF outlet temperature sensor.

Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 8 (CPC) 2-Channel Accelerator Pedal Supply Voltage Missing
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 7 (CPC) Accelerator Pedal Sensor Failed High
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (CPC) Accelerator Pedal Supply Voltage Circuit Failed Low
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (ACM) Aftertreatment Control Module 2 Sensor Supply 2 Short to Ground
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (MCM) 5V Sensor Supply Bank 2 Circuit Failed Low
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 3 (ACM) Aftertreatment Control Module 2 Sensor Supply 2 Short to Battery