Detroit DD15 EPA10 (2010-13) Fault Code: SPN 171 FMI 3 (ACM) Ambient Air Temperature Circuit Failed High

NOTE: Please see the step by step troubleshooting procedures for this specific code.

PROBABLE CAUSES:
1. Ambient air temperature sensor not programmed correctly in ECM.
2. Ambient air temperature sensor connector/harness.
3. Ambient air temperature sensor.

Detroit DD15 EPA10 (2010-13) Fault Code: SPN 171 FMI 2 (CPC) Ambient Temperature Sensor Data Erratic
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 168 FMI 14 (MCM, CPC) ECU Power Down Not Completed (Main Battery Terminal Possibly Floating)
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 168 FMI 1 (MCM, CPC) Battery Voltage Low
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 168 FMI 0 (MCM, CPC) Battery Voltage High
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 164 FMI 21 (MCM) Fuel Rail Pressure Sensor Drift Low