NOTE: This code sets when the common powertrain controller (CPC) detects the voltage on the sensor supply circuits is out of range.
DESCRIPTION:Remote accelerator pedal supply voltage circuit failed low.
MONITORED PARAMETER:Remote accelerator pedal voltage.
TYPICAL ENABLING CONDITIONS:Always on
MONITOR SEQUENCE:Key on
EXECUTION FREQUENCY:None
TYPICAL DURATION:None
DASH LAMPS:CEL
ENGINE REACTION:Idle only
VERIFICATION:1. Ignition key2. Cycle on
POSSIBLE CAUSES:1. Remote accelerator pedal assembly.2. Circuit fault.3. Fault within the CPC.4. Improper configuration of the CPC.
NOTE: This code always indicates to replace the MCM.