DESCRIPTION:Hydrocarbon (HC) doser circuit failed.
MONITORED PARAMETER:HC doser circuit.
TYPICAL ENABLING CONDITIONS:Always enabled
MONITOR SEQUENCE:None
EXECUTION FREQUENCY:Always enabled
TYPICAL DURATION:Two seconds
DASH LAMPS:1. MIL2. CEL
ENGINE REACTION:Derate 25%
VERIFICATION:Engine Idle: One minute.
PROBABLE CAUSES:1. Wiring between the EDV and the 120-pin ECM connection.2. Metering unit failure.3. Electronic dosing valve failure.
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3471 FMI 3 (MCM) Hydrocarbon Electronic Dosing Valve Circuit Failed High
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3471 FMI 1 (MCM) Electronic Dosing Valve Failed Self Test
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3364 FMI 18 (ACM) Improper Diesel Exhaust Fluid Quality Warning
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3364 FMI 17 (ACM) Improper Diesel Exhaust Fluid Quality Warning
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3364 FMI 2 (ACM) Improper Diesel Exhaust Fluid Quality
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3364 FMI 1 (ACM) Improper Diesel Exhaust Fluid Quality Final Warning