Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3216 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Rationality Error

DESCRIPTION:
 This fault code sets when the difference between the expected NOX ppm and the actual NOx ppm is greater than 200
 ppm.
 MONITORED PARAMETER:
 Aftertreatment inlet NOx sensor.
 TYPICAL ENABLING CONDITIONS:
 General Enabling Conditions: Engine is not in regeneration and operating at high speed and loads.
 Engine Parameter:
 1. Engine Speed (rpm)

– Min: 1350– Max 1600
 2. Torque (Nm):– Min: 1100– Max: 1500
 3. Battery Voltage (Volts):– Min: 11.08
 4. Engine Coolant Outlet Temperature:– Min: 70°C (158°F)
 5. Ambient Temperature– Min: -8°C (17.6°F)
 6. Barometric Pressure (mbar):– Min: 755
 7. Time Since DPF Regeneration (min.):– Min: 15
 MONITOR SEQUENCE:
 None
 EXECUTION FREQUENCY:
 Continuous when enabling conditions met.
 TYPICAL DURATION:
 150 seconds (2 cycle)
 DASH LAMPS:
 MIL
 ENGINE REACTION:
 None
 VERIFICATION:
 1. Warm up the engine and ensure engine is not in regeneration mode

2. Drive a fully loaded trailer on highway and maintain above enabling conditions for 150 seconds.
 NOTE: If any other EGR codes are active, fix those first.
 PROBABLE CAUSES:
 1. Inspect the entire air inlet system, charge air cooler, and EGR piping/hoses.
 2. Check for failed injector.
 3. Check the aftertreatment system for leaks/damage.
 4. Perform a high idle regeneration.
 Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3187 FMI 9 (CPC) CPC has Lost
 Communication with the DT12 Shift Stalk Lever
 Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3064 FMI 13 (MCM) MCM Needs to be
 Reprogrammed
 Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3058 FMI 13 (MCM) MCM Needs to be
 Reprogrammed
 Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3058 FMI 10 (MCM) Exhaust Gas Recirculation
 Valve Actuator Slow Response
 Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3058 FMI 9 (MCM) Exhaust Gas Recirculation
 Flow Target Error (Low Flow)
 Detroit DD13 GHG14 (2014-16) Fault Code: SPN 3057 FMI 2 (ACM) Selective Catalyst
 Reduction Inlet NOx Sensor – Error

Share this post...

Previous post Next post