Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3446 PID: SPN: 3222 FMI: 5 Aftertreatment Intake Gas Sensor Heater- Current Below Normal or Open Circuit

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftetreatment diesel oxidation catalsyst intake temperature sensor has been above 150° C [302° F] for 5 seconds while the engine is running.

Conditions for Setting the Fault CodesAn internal circuit error was detected in the aftertreatment intake NOx sensor assembly.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be severely reduced.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment diesel oxidation catalyst intake temperature must be above 150° C [302° F] for 5 seconds before the aftertreatment intake NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

The aftertreatment intake NOx sensor has malfunctioned or is damagedThe aftertreatment intake NOx sensor internal heater has malfunctionedThe NOx sensor part number is incorrect.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3425 PID: SID 254 SPN: 4344 FMI: 5 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3423 PID: SPN: 4344 FMI: 4 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3422 PID: SPN: 4344 FMI: 3 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3418 PID: SPN: 191 FMI: 19 Transmission Output Shaft Speed- Received Network Data In Error
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3396 PID: SPN: 3750 FMI: 31 Diesel Particulate Filter 1 Conditions Not Met for Active Regeneration- Condition Exists
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3385 PID: PID 105 SPN: 411 FMI: 16 Intake Manifold 1 Temperature- Data Valid But Below Normal Operational Range- Moderately Severe Level

Read more →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 346 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory Software- Bad Intelligent Device or Component

Circuit DescriptionThe Orginal Equipment Manufacturer (OEM) wiring harness connects multiple outputs or switched inputs to the ECM which can be enabled or disabled using INSITE™ electronic service tool, such as such as the accelerator interlock/engine torque limit switch or the clutch/engine protection override switch. Many of the outputs and switched inputs share a common wire on the OEM wiring harness. Refer to the engine wiring diagram to determine which features share common wires in the OEM harness.

Component LocationNot Applicable

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected that features which share a common input or output to the ECM were simultaneously enabled..

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkMany of the outputs and switched inputs share a common wire on the OEM wiring harness. If two features that share a common OEM wire are enabled simultaneously in the ECM, this fault code will be logged. To disable the fault code, disable one of the features on the shared OEM wire. For example, if the accelerator interlock switch and powertrain protection torque limit switch are both enabled in the ECM, either disable one of the features with INSITE™ electronic service tool or configure one of the features to be multiplexed using the SAE J1939 multiplexing feature.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 343 PID: SID 254 SPN: 629 FMI: 12 Engine Control Module Warning Internal Hardware Failure- Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 339 PID: SID 87 SPN: 1267 FMI: 4 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 338 PID: SID 87 SPN: 1267 FMI: 3 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 338 PID: SID 87 SPN: 1267 FMI: 3 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 334 PID: PID 110 SPN: 110 FMI: 2 Engine Coolant Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 332 PID: SID 4 SPN: 654 FMI: 5 Injector Solenoid Driver Cylinder 4 Circuit- Current Below Normal or Open Circuit

Read more →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3488 PID: SPN: 563 FMI: 9 Anti-Lock Braking (ABS) Controller- Abnormal Update Rate

Circuit DescriptionNormally, switches, accelerators, and other components are connected to the engine control module (ECM) directly through individual wires. Multiplexing allows those same components to be hard wired to an original equipment manufacturer (OEM) vehicle electronic control unit (VECU) or transmission electronic control unit (ECU) in the cab. Then component values and states from components such as sensors, accelerators, and switches can be transmitted from the OEM VECU to the Cummins® ECM over the SAE J1939 data link.

Messages sent from OEM VECUs or transmission ECUs are received by the Cummins® ECM and used for controlling the engine. The Cummins® ECM and OEM VECU(s) must be configured properly, so that proper operation of the multiplexed components will occur.

Component LocationThe SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe ECM did not receive a message from the multiplexed device.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkWhen this fault code is active, some multiplexed devices may not function as desired.

Potential causes of this fault code include:

When the ECM is set up properly (components enabled and OEM VECU source addressed correctly) to receive information from an OEM VECU, but the OEM VECU is actually transmitting a message that says that component is not available for multiplexing. This can be caused when a multiplexed component is enabled in the Cummins® ECM, but the OEM VECU source address of the VECU transmitting the component message is incorrect in the Cummins® ECM, or the OEM VECU is not set up to transmit the multiplexed component message.This fault can also be caused by a bad J1939 data link connection between the OEM VECU and Cummins® ECM, a bad connection between the component and the OEM VECU, a bad OEM VECU, or a bad Cummins® ECM. It may be necessary to contact the OEM for proper multiplexing configuration.It is possible to use INSITE™ electronic service tool to monitor multiplexed components.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3446 PID: SPN: 3222 FMI: 5 Aftertreatment Intake Gas Sensor Heater- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3425 PID: SID 254 SPN: 4344 FMI: 5 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3423 PID: SPN: 4344 FMI: 4 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3422 PID: SPN: 4344 FMI: 3 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3418 PID: SPN: 191 FMI: 19 Transmission Output Shaft Speed- Received Network Data In Error
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3396 PID: SPN: 3750 FMI: 31 Diesel Particulate Filter 1 Conditions Not Met for Active Regeneration- Condition Exists

Read more →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3492 PID: SPN: 251 FMI: 10 Real Time Clock- Abnormal Rate of Change

Circuit DescriptionThe real-time clock consists of a timing chip internal to the engine control module (ECM) which monitors engine off time, i.e. how long the engine has been shut down.

Component LocationThe real time clock is a timing chip internal to the ECM and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs at initial key ON.

Conditions for Setting the Fault CodesThe engine off timer was not counting correctly and does not match other timers in the ECM.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

The ECM will not be able to monitor engine off time accurately.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkMonitoring the engine off time is necessary in to make sure that all other engine sensors and actuators are performing correctly. If the ECM is recalibrated or replaced during the repair and the fault code is no longer present, the instructions in the “Conditions for Clearing” section must be followed in order for the diagnostic to run again and validate the repair.

Potential causes of this fault code include:

Malfunctioning real time clock chip internal to the ECMEngine calibration issue.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3488 PID: SPN: 563 FMI: 9 Anti-Lock Braking (ABS) Controller- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3446 PID: SPN: 3222 FMI: 5 Aftertreatment Intake Gas Sensor Heater- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3425 PID: SID 254 SPN: 4344 FMI: 5 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3423 PID: SPN: 4344 FMI: 4 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3422 PID: SPN: 4344 FMI: 3 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3418 PID: SPN: 191 FMI: 19 Transmission Output Shaft Speed- Received Network Data In Error

Read more →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3497 PID: SPN: 1761 FMI: 17 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Least Severe Level

Circuit DescriptionThe aftertreatment diesel exhaust fluid level sensor is used to monitor the diesel exhaust fluid level inside the diesel exhaust fluid tank.

Component LocationThe aftertreatment diesel exhaust fluid tank level sensor is located in the aftertreatment diesel exhaust fluid tank. Location of the tank and level sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThe diagnostic runs continuously when the following conditions are met:

Keyswitch is in the ON position or when the engine is running.Ambient temperature is above -20°C [-4°F].Vehicle altitude change is less than 305 m [1000 ft] in 1 hour.Conditions for Setting the Fault CodesThe diesel exhaust fluid tank level was low.

Action Taken When the Fault Code is ActiveThe Diesel Exhaust Fluid Lamp will be illuminated.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the diesel exhaust fluid lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code indicates that the diesel exhaust fluid level is low, and the tank must be refilled at the operator’s earliest convenience.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3492 PID: SPN: 251 FMI: 10 Real Time Clock- Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3488 PID: SPN: 563 FMI: 9 Anti-Lock Braking (ABS) Controller- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3446 PID: SPN: 3222 FMI: 5 Aftertreatment Intake Gas Sensor Heater- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3425 PID: SID 254 SPN: 4344 FMI: 5 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3423 PID: SPN: 4344 FMI: 4 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3422 PID: SPN: 4344 FMI: 3 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3498 PID: SPN: 1761 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe aftertreatment diesel exhaust fluid level sensor is used to monitor the diesel exhaust fluid level inside the diesel exhaust fluid tank.

Component LocationThe aftertreatment diesel exhaust fluid tank level sensor is located in the aftertreatment diesel exhaust fluid tank. Location of the tank and level sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThe diagnostic runs continuously when the following conditions are met:

Keyswitch is in the ON position or when the engine is running.Ambient temperature is above -20°C [-4°F].Vehicle altitude change is less than 305 m [1000 ft] in 1 hour.Conditions for Setting the Fault CodesThe diesel exhaust fluid tank level was very low.

Action Taken When the Fault Code is ActiveThe Diesel Exhaust Fluid Lamp will be flashing.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the diesel exhaust fluid lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code indicates that the diesel exhaust fluid level is very low. The diesel exhaust fluid tank must be refilled.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3497 PID: SPN: 1761 FMI: 17 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3492 PID: SPN: 251 FMI: 10 Real Time Clock- Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3488 PID: SPN: 563 FMI: 9 Anti-Lock Braking (ABS) Controller- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3446 PID: SPN: 3222 FMI: 5 Aftertreatment Intake Gas Sensor Heater- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3425 PID: SID 254 SPN: 4344 FMI: 5 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3423 PID: SPN: 4344 FMI: 4 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 351 PID: PID 110 SPN: 627 FMI: 12 Injector Power Supply- Bad Intelligent Device or Component

Circuit DescriptionBetween each injection event, the Engine Control Module (ECM) attempts to recharge the injector power supply. The injector power supply consists of a bank of capacitors; if this power supply is maintained at high voltage. Recharging is accomplished by recovering energy stored in the injector solenoids. For the injector power supply to remain fully charged, there must be good ECM battery power and ground, a good engine speed sensor, and good injector circuits.

Component LocationThe engine harness connects the ECM to the pass-through connector(s) that are located in the rocker housing. Internal injector harnesses are located under the valve cover and connect the injectors to the engine harness at the pass-through connector(s).

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the measured injector power supply voltage was less than the commanded injector power supply voltage.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code will become active after key ON if the battery charge is above a minimum threshold, and, at the same time, the measured injector power supply voltage is lower than the commanded injector power supply voltage.

Possible Cause:1) ECM failure2) ECM power supply harness, Fuses, fuses holders3) Battery Terminals4) Battery Failure

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 346 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory Software- Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 343 PID: SID 254 SPN: 629 FMI: 12 Engine Control Module Warning Internal Hardware Failure- Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 339 PID: SID 87 SPN: 1267 FMI: 4 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 338 PID: SID 87 SPN: 1267 FMI: 3 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 338 PID: SID 87 SPN: 1267 FMI: 3 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 334 PID: PID 110 SPN: 110 FMI: 2 Engine Coolant Temperature- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 352 PID: SID 212 SPN: 3509 FMI: 4 Sensor Supply 1 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe sensor supply 1 circuit of the engine control module (ECM) provides a 5 volt supply to various sensors on the engine harness. Refer to the wiring diagram for sensor supply identification.

Component LocationSensor Supply 1 originates in the Engine Wiring Harness portion of the ECM. It supplies 5 volts to sensors in the engine wiring harness.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the sensor supply 1 signal voltage was less than 4.75-VDC for more than one second.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value is used for all of the sensors on the sensor supply 1 circuit.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkLow voltage on the +5 volt supply wire can be caused by a short circuit to ground in a supply wire, a short circuit between a supply wire and a return wire, a malfunctioning sensor, or a malfunctioning ECM power supply.

During the fault code response test outlined for each sensor connected to sensor supply number 1, Fault Code 352 must be active before unplugging each sensor. If the fault code is not active, but can be easily duplicated by operating the engine, the following can be performed:

• Operate the engine under the conditions that will cause Fault Code 352 to become active, even if it logs for a short period of time. Unplug one sensor at a time until Fault Code 352 stops logging under the test conditions. Each sensor can be unplugged with the engine running. Note: The engine may not start if the camshaft position sensor is unplugged.

Possible Cause:1) Camshaft position sensor failure2) Intake manifold pressure/temperature sensor failure3) Crankcase pressure sensor failure4) Engine oil pressure sensor failure5) Barometric air pressure sensor failure6) Engine harness7) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 351 PID: PID 110 SPN: 627 FMI: 12 Injector Power Supply- Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 346 PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory Software- Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 343 PID: SID 254 SPN: 629 FMI: 12 Engine Control Module Warning Internal Hardware Failure- Bad Intelligent Device or Component
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 339 PID: SID 87 SPN: 1267 FMI: 4 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 338 PID: SID 87 SPN: 1267 FMI: 3 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 338 PID: SID 87 SPN: 1267 FMI: 3 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3525 PID: SPN: 84 FMI: 19 Wheel-Based Vehicle Speed- Received Network Data In Error

Circuit DescriptionNormally, switches, accelerators, and other components are connected to the engine control module (ECM) directly through individual wires. Multiplexing allows those same components to be hard wired to an original equipment manufacturer (OEM) vehicle electronic control unit (VECU) or transmission electronic control unit (ECU) in the cab. Then component values and states from components such as sensors, accelerators, and switches can be transmitted from the OEM VECU to the Cummins® ECM over the SAE J1939 data link.

Messages sent from OEM VECUs or transmission ECUs are received by the Cummins® ECM and used for controlling the engine. The Cummins® ECM and OEM VECU(s) must be configured properly, so that proper operation of the multiplexed components will occur.

Component LocationThe SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe OEM VECU determined that there was a malfunction of the wheel-based vehicle speed sensor.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe J1939 multiplexing controller has indicated a malfunction of the wheel-based vehicle speed sensor.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3498 PID: SPN: 1761 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3497 PID: SPN: 1761 FMI: 17 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3492 PID: SPN: 251 FMI: 10 Real Time Clock- Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3488 PID: SPN: 563 FMI: 9 Anti-Lock Braking (ABS) Controller- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3446 PID: SPN: 3222 FMI: 5 Aftertreatment Intake Gas Sensor Heater- Current Below Normal or Open Circuit
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3425 PID: SID 254 SPN: 4344 FMI: 5 Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit- Current Below Normal or Open Circuit

Read more →

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3526 PID: SPN: 84 FMI: 9 Wheel-Based Vehicle Speed- Abnormal Update Rate

Circuit DescriptionNormally, switches, accelerators, and other components are connected to the engine control module (ECM) directly through individual wires. Multiplexing allows those same components to be hard wired to an original equipment manufacturer (OEM) vehicle electronic control unit (VECU) or transmission electronic control unit (ECU) in the cab. Then component values and states from components such as sensors, accelerators, and switches can be transmitted from the OEM VECU to the Cummins® ECM over the SAE J1939 data link.

Messages sent from OEM VECUs or transmission ECUs are received by the Cummins® ECM and used for controlling the engine. The Cummins® ECM and OEM VECU(s) must be configured properly, so that proper operation of the multiplexed components will occur.

Component LocationThe SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe ECM did not receive a message from the multiplexed device.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkWhen this fault code is active, some multiplexed devices may not function as desired.

Possible causes of this fault code include:

When the ECM is set up properly (components enabled and OEM VECU source addressed correctly) to receive information from an OEM VECU, but the OEM VECU is actually transmitting a message that says that component is not available for multiplexing. This can be caused when a multiplexed component is enabled in the Cummins® ECM, but the OEM VECU source address of the VECU transmitting the component message is incorrect in the Cummins® ECM, or the OEM VECU is not set up to transmit the multiplexed component message.This fault can also be caused by a bad J1939 data link connection between the OEM VECU and Cummins® ECM, a bad connection between the component and the OEM VECU, a bad OEM VECU, or a bad Cummins® ECM. It may be necessary to contact the OEM for proper multiplexing configuration.It is possible to use INSITE™ electronic service tool to monitor multiplexed components.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM harness2) ECM failure

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3525 PID: SPN: 84 FMI: 19 Wheel-Based Vehicle Speed- Received Network Data In Error
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3498 PID: SPN: 1761 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3497 PID: SPN: 1761 FMI: 17 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3492 PID: SPN: 251 FMI: 10 Real Time Clock- Abnormal Rate of Change
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3488 PID: SPN: 563 FMI: 9 Anti-Lock Braking (ABS) Controller- Abnormal Update Rate
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3446 PID: SPN: 3222 FMI: 5 Aftertreatment Intake Gas Sensor Heater- Current Below Normal or Open Circuit

Read more →