Circuit DescriptionThe coolant temperature sensor is a variable resistor sensor and is used to measure the temperature of the coolant of the engine. The engine control module (ECM) supplies 5 volts to the coolant temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the coolant temperature.
Component LocationThe engine coolant temperature sensor is located on the thermostat housing.
Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine coolant temperature was greater than 107°C [225°F].
Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.The torque output of the engine will be reduced.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop TalkThis fault code indicates that coolant temperature has exceeded the engine protection limits for high coolant temperature. Refer to Engine Coolant Temperature Above Normal symptom troubleshooting tree in the base engine service manual.
Possible Cause:1) Coolant temperature sensor failure2) ECM calibration
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2962 PID: PID 412 SPN: 412 FMI: 16 Exhaust Gas Recirculation Temperature- Data valid But Above Normal Operational Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2961 PID: PID 412 SPN: 412 FMI: 15 Exhaust Gas Recirculation Temperature- Data valid But Above Normal Operational Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2881 PID: SID 332 SPN: 3480 FMI: 17 Aftertreatment Fuel Pressure Sensor- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2789 PID: PID 110 SPN: 110 FMI: 18 Engine Coolant Temperature- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2777 PID: SID 390 SPN: 3703 FMI: 31 Particulate Trap Active Regeneration inhibited Due to Inhibit Switch- Condition Exists
Circuit DescriptionThe Engine Control Module (ECM) provides 5 volts to the intake manifold temperature signal circuit, and monitors the change in voltage caused by changes in the resistance of the sensor to determine the intake manifold temperature. When the intake air is cold, the sensor (or thermistor) resistance is high. The ECM signal voltage only pulls down a small amount through the sensor to a ground. Therefore, the ECM senses a high signal voltage or low temperature. When the intake air is warm, the sensor resistance is low. The signal voltage pulls down a large amount. Therefore, the ECM senses a low signal voltage, or a high temperature.
Component LocationThe intake manifold 1 pressure/temperature sensor is located in the air intake horn.
Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the intake manifold temperature was greater than 120°C [248°F].
Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.The torque output of the engine will be reduced.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop TalkThe intake manifold 1 temperature sensor measures the temperature of the charge-air as it passes through the intake manifold.
Possible causes of this fault code include:
Plugged charge-air cooler finsRestricted airflow through the charge-air coolerAn undersized charge-air coolerHigh turbocharger compressor outlet temperature.
Possible Cause:1) Intake Manifold temperature sensor failure2) ECM calibration
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2963 PID: PID 110 SPN: 110 FMI: 15 Engine Coolant Temperature- Data Valid But Above Normal Operational Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2962 PID: PID 412 SPN: 412 FMI: 16 Exhaust Gas Recirculation Temperature- Data valid But Above Normal Operational Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2961 PID: PID 412 SPN: 412 FMI: 15 Exhaust Gas Recirculation Temperature- Data valid But Above Normal Operational Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2881 PID: SID 332 SPN: 3480 FMI: 17 Aftertreatment Fuel Pressure Sensor- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2789 PID: PID 110 SPN: 110 FMI: 18 Engine Coolant Temperature- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2777 PID: SID 390 SPN: 3703 FMI: 31 Particulate Trap Active Regeneration inhibited Due to Inhibit Switch- Condition Exists
Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the intake manifold pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The intake manifold pressure sensor provides a signal to the ECM on the intake manifold pressure sensor signal circuit. This sensor signal voltage changes based on the pressure in the intake manifold.
Component LocationThe intake manifold 1 pressure/temperature sensor is located in the air intake manifold.
Conditions for Running the DiagnosticsThis diagnostic consists of two parts:
One part runs immediately after the keyswitch is turned OFF, and the engine coolant temperature is above 70°C or 158°F.
The second part occurs when the engine is operating.
Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the intake manifold pressure sensor was reading higher or lower than expected at keyoff or during normal engine operation.
Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value of the intake manifold pressure reading is used.Diesel exhaust fluid injection into the aftertreatment system is disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, first ensure the engine coolant temperature is above 70°C or 158°F. Operate the engine if necessary.Cycle the keyswitch to the ON position for 30 seconds, then cycle the keyswitch to the OFF position for 30 seconds. Start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop TalkThis diagnostic consists of two parts. At key OFF, the sensor readings for intake manifold pressure, barometric air pressure, oil pressure (if available), and exhaust gas pressure are compared to each other. This fault code occurs if the intake manifold pressure sensor reading is different from the other sensor readings. This check is only done once after the keyswitch is turned OFF. This fault can also be set active when the intake manifold pressure is too high or low for the current engine operating conditions when the engine is running. The ECM compares the intake manifold pressure reading to turbocharger speed to determine if the pressure reading is valid.
Possible causes of this fault are:
A damaged turbocharger speed sensorA damaged barometric pressure sensorLeaks in the air intake system between the turbocharger and intake manifoldRestriction in the charge-air coolerA damaged intake manifold pressure sensorA damaged turbocharger compressor intake temperature sensor.
Circuit DescriptionThe aftertreatment diesel exhaust fluid dosing unit precisely measures the amount of aftertreatment diesel exhaust fluid to be injected into the aftertreatment system. The aftertreatment diesel exhaust fluid dosing unit has three primary cycles. A priming cycle makes sure that aftertreatment diesel exhaust fluid is available at the aftertreatment diesel exhaust fluid dosing unit. During the dosing cycle, aftertreatment diesel exhaust fluid is being delivered to the aftertreatment dosing valve. A purge cycle occurs when the engine is turned OFF. The purge cycle makes sure that all the aftertreatment diesel exhaust fluid is removed from the diesel exhaust fluid lines and dosing valve.
Component LocationThe aftertreatment diesel exhaust fluid dosing unit location is original equipment manufacturer (OEM) dependent. Refer to the OEM service manual.
Conditions for Running the DiagnosticsThis diagnostic runs immediately after the keyswitch is turned to the ON position, and continues until the diesel exhaust fluid dosing unit attempts to prime.
Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid dosing unit internal temperature was not communicated to the ECM by the diesel exhaust dosing unit.
Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.
Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.
Conditions for Clearing the Fault CodeStart the engine and let it idle. If, after the engine idles for 10 minutes, the fault code is still not active, the repair has been validated.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop TalkPossible causes of this fault code include:
Malfunctioning dosing unitShort circuit to ground in the aftertreatment diesel exhaust fluid dosing unit signal/dosing unit temperature wire.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.
Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the aftertreatment diesel particulate filter outlet pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The aftertreatment diesel particulate filter outlet pressure sensor provides a signal to the ECM on the aftertreatment diesel particulate filter outlet pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the outlet of the aftertreatment diesel particulate filter.
Component LocationThe aftertreatment diesel particulate filter differential pressure sensor is mounted on the diesel particulate filter. It is a combination sensor that detects both diesel particulate filter differential pressure and outlet pressure. Refer to the original equipment manufacturer (OEM) service manual.
Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter outlet pressure signal voltage was greater than 4.75-VDC for more than 2 seconds.
Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop TalkPossible causes of this fault include:
Open return circuit in the harness, connectors, or sensorSignal circuit shorted to sensor supply or battery voltage.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.
For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.
Possible Cause:1) OEM harness2) ECM calibration
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2976 PID: SPN: 3361 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Temperature- Data Erratic, Intermittent, or Incorrect
Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the aftertreatment diesel particulate filter outlet pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The aftertreatment diesel particulate filter outlet pressure sensor provides a signal to the ECM on the aftertreatment diesel particulate filter outlet pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the outlet of the aftertreatment diesel particulate filter.
Component LocationThe aftertreatment diesel particulate filter differential pressure sensor is mounted on the diesel particulate filter. It is a combination sensor that detects both diesel particulate filter differential pressure and outlet pressure. Refer to the original equipment manufacturer (OEM) service manual.
Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter outlet pressure signal voltage was less than 0.25-VDC for more than 2 seconds.
Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop TalkPossible causes of this fault include:
Signal circuit open or shorted to ground in the engine harness or sensorSupply line open or shorted to ground.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.
Possible Cause:1) OEM harness2) ECM calibration
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3133 PID: SPN: 3610 FMI: 3 Aftertreatment Diesel Particulate Filter Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 2976 PID: SPN: 3361 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Temperature- Data Erratic, Intermittent, or Incorrect
Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the aftertreatment diesel particulate filter outlet pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The aftertreatment diesel particulate filter outlet pressure sensor provides a signal to the ECM on the aftertreatment diesel particulate filter outlet pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the outlet of the aftertreatment diesel particulate filter.
Component LocationThe aftertreatment diesel particulate filter differential pressure sensor is mounted on the diesel particulate filter. It is a combination sensor that detects both diesel particulate filter differential pressure and outlet pressure. Refer to the original equipment manufacturer (OEM) service manual.
Conditions for Running the DiagnosticsThis diagnostic consists of two parts:
One part runs when the keyswitch is initially turned ON before the engine is startedThe second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel particulate filter outlet pressure was greater than 1.5 kpa [0.22 psi] or less than -1.5 kpa [0.22 psi] at initial key ON, or was not changing with engine conditions.
Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.
Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.Turn the key switch OFF and allow the ECM to completely powerdown.To validate the repair, perform a key cycle and leave the key in the ON position for 2 minutes. Then start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop TalkPossible causes of this fault code include:
Stuck in-range aftertreatment diesel particulate filter outlet pressure sensor readingHigh resistance in the aftertreatment diesel particulate filter outlet pressure sensor signal or return wiresHigher than expected diesel particulate filter outlet pressureExcessive diesel exhaust fluid (DEF) deposits in the aftertreatment decomposition tubePlugged aftertreatment outlet pressure sensor ports could cause this fault code if pressure is held in the port after the engine is turned OFF.Frozen, plugged, or restricted aftertreatment DPF differential pressure sensor tubes.Note: It is possible to set this fault in a shop environment by performing a key cycle with the tailpipe connected to an exhaust ventilation system.
Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.
Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the EGR orifice pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The EGR orifice pressure sensor provides a signal to the ECM on the EGR orifice pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the EGR orifice pressure sensor.
Component LocationThe EGR orifice pressure sensor is mounted on the EGR mass measurement assembly near the EGR differential pressure sensor.
Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the EGR orifice pressure sensor signal voltage was greater than 4.75-volts for 5 seconds.
Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop TalkPossible causes of this fault include:
Open return circuit in the harness, connectors, or sensorSignal circuit shorted to sensor supply or battery voltage.
Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the EGR orifice pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The EGR orifice pressure sensor provides a signal to the ECM on the EGR orifice pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the EGR orifice pressure sensor.
Component LocationThe EGR orifice pressure sensor is mounted on the EGR mass measurement assembly near the EGR differential pressure sensor.
Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.
Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the EGR orifice pressure sensor signal voltage was less than 0.25 volts for 5 seconds.
Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop TalkPossible causes of this fault include:
Signal circuit open or shorted to ground in the engine harness or sensorSupply line open or shorted to ground.
Possible Cause:1) ECM failure2) Engine harness
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source
Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the EGR orifice pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The EGR orifice pressure sensor provides a signal to the ECM on the EGR orifice pressure sensor signal circuit. This sensor signal voltage changes based on the pressure at the EGR orifice pressure sensor.
Component LocationThe EGR orifice pressure sensor is mounted on the EGR mass measurement assembly near the EGR differential pressure sensor.
Conditions for Running the DiagnosticsThis is a two part diagnostic.
One part runs immediately after the keyswitch is turned OFF, and the engine coolant temperature is above 70°C or 158°F.
The second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the EGR orifice pressure sensor was not changing with engine conditions or was incorrect at key OFF.
Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.
Shop TalkPossible causes of this fault code include:
A damaged EGR orifice pressure sensorHigh resistance in the wiring harness on the signal or return wirePlugged or restricted EGR differential pressure sensor flow ports.
Possible Cause:1) ECM calibration
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3137 PID: SPN: 5019 FMI: 4 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 3136 PID: SPN: 5019 FMI: 3 Engine Exhaust Gas Recirculation Outlet Pressure Sensor Circuit- Voltage Above Normal or Shorted to High source