Skip to content Skip to side menu

Cumminz

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (Multiplexed) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank temperature sensor is used to monitor the temperature of the aftertreatment diesel exhaust fluid inside the aftertreatment diesel exhaust fluid tank.

Component LocationThe aftertreatment diesel exhaust fluid tank temperature sensor is located in the diesel exhaust fluid tank. Location of the tank and temperature sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature signal voltage was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment diesel exhaust fluid tank temperature sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (HW) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1673 PID: SPN: 1761 FMI: 1 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1669 (Multiplexed) PID: SPN: 1761 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1669 (3 Wire) PID: PID 203D SPN: 1761 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Level Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1669 (2 Wire) PID: PID 203D SPN: 1761 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Level Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1668 (Multiplexed) PID: SPN: 1761 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (HW) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank temperature sensor is used to monitor the temperature of the aftertreatment diesel exhaust fluid inside the aftertreatment diesel exhaust fluid tank.

Component LocationThe aftertreatment diesel exhaust fluid tank temperature sensor is located in the diesel exhaust fluid tank. Location of the tank and temperature sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature signal voltage was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Engine torque will be severely reduced.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment diesel exhaust fluid tank temperature sensorOpen return circuit in the harness, connectors, or sensorOpen signal circuit or shorted to a voltage source.The type of diesel exhaust fluid tank temperature and level sensor used can vary depending on the vehicle OEM. As a result, the physical and/or electrical sensor configuration may vary slightly from what is shown in the troubleshooting and wiring diagram information.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) OEM harness2) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (Multiplexed) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (HW) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1673 PID: SPN: 1761 FMI: 1 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1669 (Multiplexed) PID: SPN: 1761 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1669 (3 Wire) PID: PID 203D SPN: 1761 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Level Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1669 (2 Wire) PID: PID 203D SPN: 1761 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Level Sensor Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (Multiplexed) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank temperature sensor is used to monitor the temperature of the aftertreatment diesel exhaust fluid inside the aftertreatment diesel exhaust fluid tank.

Component LocationThe aftertreatment diesel exhaust fluid tank temperature sensor is located in the diesel exhaust fluid tank. Location of the tank and temperature sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature signal voltage was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment diesel exhaust fluid tank temperature sensorReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (HW) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (Multiplexed) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (HW) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1673 PID: SPN: 1761 FMI: 1 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1669 (Multiplexed) PID: SPN: 1761 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1669 (3 Wire) PID: PID 203D SPN: 1761 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Level Sensor Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (HW) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank temperature sensor is used to monitor the temperature of the aftertreatment diesel exhaust fluid inside the aftertreatment diesel exhaust fluid tank.

Component LocationThe aftertreatment diesel exhaust fluid tank temperature sensor is located in the diesel exhaust fluid tank. Location of the tank and temperature sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThe engine must be turned OFF for period of 8 hours before this diagnostic will run. This diagnostic runs when the keyswitch is turned to the ON position after an 8 hour cold soak.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature sensor reading was higher or lower than the other temperature sensors on the engine.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, the engine must be shut down with the keyswitch in the OFF position for 8 hours. After the 8 hour cold soak, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

In-range failure of the diesel exhaust fluid tank temperature sensorDamaged wiring harnessThe type of diesel exhaust fluid tank temperature and level sensor used can vary depending on the vehicle OEM. As a result, the physical and/or electrical sensor configuration may vary slightly from what is shown in the troubleshooting and wiring diagram information.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DEF tank temperature sensor failure2) OEM harness3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (Multiplexed) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (HW) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (Multiplexed) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (HW) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1673 PID: SPN: 1761 FMI: 1 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1669 (Multiplexed) PID: SPN: 1761 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (Multiplexed) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank temperature sensor is used to monitor the temperature of the aftertreatment diesel exhaust fluid inside the aftertreatment diesel exhaust fluid tank.

Component LocationThe aftertreatment diesel exhaust fluid tank temperature sensor is located in the diesel exhaust fluid tank. Location of the tank and temperature sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThe engine must be turned OFF for period of 8 hours before this diagnostic will run. This diagnostic runs when the keyswitch is turned to the ON position after an 8 hour cold soak.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank temperature sensor reading was higher or lower than the other temperature sensors on the engine.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, the engine must be shut down with the keyswitch in the OFF position for 8 hours. After the 8 hour cold soak, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

In-range failure of the diesel exhaust fluid tank temperature sensorDamaged wiring harnessThe type of diesel exhaust fluid tank temperature and level sensor used can vary depending on the vehicle OEM. As a result, the physical and/or electrical sensor configuration may vary slightly from what is shown in the troubleshooting and wiring diagram information.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment DEF tank level/temperature/quality sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (HW) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (Multiplexed) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (HW) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (Multiplexed) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (HW) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1673 PID: SPN: 1761 FMI: 1 Aftertreatment 1 Diesel Exhaust Fluid Tank Level- Data Valid But Below Normal Operating Range- Most Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1682 PID: SPN: 3362 FMI: 31 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input Lines- Condition Exists

Circuit DescriptionThe diesel exhaust fluid dosing unit lines are responsible for transporting diesel exhaust fluid between the dosing unit, dosing valve, and diesel exhaust fluid tank.

Component LocationThere are three diesel exhaust fluid lines. One line is between the dosing unit and dosing valve, and the other two lines are between the dosing unit and the diesel exhaust fluid tank. These lines can be partially hidden from view by the SCR system and other vehicle components. Line routing will vary, based on the aftertreatment architecture and the OEM.

Conditions for Running the DiagnosticsThis diagnostic runs when the SCR system is trying to prime.

Conditions for Setting the Fault CodesThe aftertreatment diesel exhaust fluid dosing unit was unable to successfully prime after multiple attempts.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine torque will be severely reduced.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault CodeTo validate the repair, perform the “Aftertreatment Diesel Exhaust Fluid System Leak Test” found under “ECM Diagnostic Tests” in the INSITE™ electronic service toolThe fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Low aftertreatment diesel exhaust fluid level in the diesel exhaust fluid tankThe line heaters are not successfully thawing the frozen diesel exhaust fluidThe diesel exhaust fluid pressure line between the dosing unit and dosing valve is kinked, broken, or disconnectedThe diesel exhaust fluid suction line between the diesel exhaust fluid tank and the dosing unit is kinked, broken, or disconnectedMalfunctioning diesel exhaust fluid dosing unitThe diesel exhaust fluid suction and return lines between the dosing unit and diesel exhaust fluid tank are reversedDebris from the diesel exhaust fluid tank. If debris is found in the diesel exhaust fluid tank, clean the diesel exhaust fluid tank thoroughly and fill with certified diesel exhaust fluid.

Possible Cause:1) Aftertreatment DEF dosing unit intake filter fitting failure2) DEF tank filter failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (Multiplexed) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (HW) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (Multiplexed) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (HW) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (Multiplexed) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (HW) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1683 PID: SPN: 3363 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank heater keeps the diesel exhaust fluid from freezing in the diesel exhaust fluid tank. The tank heater consists of an electrically powered tank heater control valve which controls the flow of engine coolant to a heating coil inside the diesel exhaust fluid tank. The tank heater control valve opens to allow coolant to flow to the heating coil when heating is commanded, and closes when heating is no longer required.

Component LocationThe diesel exhaust fluid tank heater control valve is located near the diesel exhaust fluid tank. Specific location will vary depending on the vehicle OEM. The tank heating coil is internal to the diesel exhaust fluid tank.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when diesel exhaust fluid tank heating is being commanded.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank heater circuit is shorted to battery or open circuit.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid tank heating will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and then use INSITE™ electronic service tool to perform the Diesel Exhaust Fluid Doser System Heater Test found under ECM Diagnostic Tests.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Diesel exhaust fluid tank heater signal wire and return wire shorted togetherMalfunctioning diesel exhaust fluid tank heater control valveReference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1682 PID: SPN: 3362 FMI: 31 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input Lines- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (Multiplexed) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (HW) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (Multiplexed) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (HW) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1677 (Multiplexed) PID: SPN: 3031 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid tank Temperature Sensor- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1684 PID: SPN: 3363 FMI: 4 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank heater keeps the diesel exhaust fluid from freezing in the diesel exhaust fluid tank. The tank heater consists of an electrically powered tank heater control valve which controls the flow of engine coolant to a heating coil inside the diesel exhaust fluid tank. The tank heater control valve opens to allow coolant to flow to the heating coil when heating is commanded, and closes when heating is no longer required.

Component LocationThe diesel exhaust fluid tank heater control valve is located near the diesel exhaust fluid tank. Specific location will vary depending on the vehicle OEM. The tank heating coil is internal to the diesel exhaust fluid tank.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when diesel exhaust fluid tank heating is being commanded.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected low signal voltage or a short to ground at the diesel exhaust fluid tank heater circuit.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Diesel exhaust fluid tank heating will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and then use INSITE™ electronic service tool to perform the Diesel Exhaust Fluid Doser System Heater Test found under ECM Diagnostic Tests.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Malfunctioning diesel exhaust fluid tank heater control valveA short circit to ground

Possible Cause:1) OEM harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1683 PID: SPN: 3363 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1682 PID: SPN: 3362 FMI: 31 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input Lines- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (Multiplexed) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (HW) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (Multiplexed) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (HW) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1685 PID: SPN: 3364 FMI: 4 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid quality sensor is a smart device that communicates to the ECM via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor performs its own internal diagnostics and reports malfunctions back to the primary engine contol module via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor is used to measure the concentration of the aftertreatment diesel exhaust fluid in the tank.

Component LocationThe aftertreatment diesel exhaust fluid quality sensor is located in the aftertreatment diesel exhaust fluid tank. It may be a combination sensor with the aftertreatement diesel exhaust fluid tank level and tank temperature sensors. Location of the tank and sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Aftertreatment DEF quality sensor reported an out of range low condition.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults.

Shop TalkPossible caused of this fault code include:

Malfunctioning DEF Quality Sensor

Possible Cause:1) Aftertreatment DEF quality sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1684 PID: SPN: 3363 FMI: 4 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1683 PID: SPN: 3363 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1682 PID: SPN: 3362 FMI: 31 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input Lines- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (Multiplexed) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (HW) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1678 (Multiplexed) PID: SPN: 3031 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1686 PID: SPN: 3364 FMI: 3 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment diesel exhaust fluid quality sensor is a smart device that communicates to the ECM via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor performs its own internal diagnostics and reports malfunctions back to the primary engine contol module via the J1939 datalink. The aftertreatment diesel exhaust fluid quality sensor is used to measure the concentration of the aftertreatment diesel exhaust fluid in the tank.

Component LocationThe aftertreatment diesel exhaust fluid quality sensor is located in the aftertreatment diesel exhaust fluid tank. It may be a combination sensor with the aftertreatement diesel exhaust fluid tank level and tank temperature sensors. Location of the tank and sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Aftertreatment DEF quality sensor reported an out of range high condition.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults.

Shop TalkPossible caused of this fault code include:

Malfunctioning DEF Quality Sensor

Possible Cause:1) Aftertreatment DEF quality sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1685 PID: SPN: 3364 FMI: 4 Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1684 PID: SPN: 3363 FMI: 4 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1683 PID: SPN: 3363 FMI: 3 Aftertreatment Diesel Exhaust Fluid Tank Heater- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1682 PID: SPN: 3362 FMI: 31 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input Lines- Condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (Multiplexed) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 1679 (HW) PID: SPN: 3031 FMI: 2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Data Erratic, Intermittent, or Incorrect