Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6459 PID: SPN: 3216 FMI: 2/21 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted Low

Lamp:None

Reason:An offset in the intake NOx sensor reading has been detected.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment intake NOx (Nitrogen Oxides) sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component Location:The aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the Diagnostics:1. This diagnostic runs when the aftertreatment diesel oxidation catalyst intake temperature sensor has been above 150°C [302°F] for 5 minutes while the engine is running.2. This diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the aftertreatment intake NOx reading was higher or lower than the calculated aftertreatment intake NOx value for the engine operating conditions.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. Start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using the recommended diagnostic tool or equivalent.2. The aftertreatment diesel oxidation catalyst intake temperature must be above 150°C [302°F] for 5 minutes before the aftertreatment intake NOx sensor can run its internal diagnostics.3. To validate the repair, it is necessary to drive the vehicle and operate it in a motoring condition for 10 seconds continuously.4. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.5. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.6. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.7. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. EGR system leaks.2. Exhaust system leaks.3. An incorrectly installed aftertreatment intake NOx sensor.4. An aftertreatment intake NOx sensor that has carbon buildup on the tip of the sensor.5. A malfunctioning EGR differential pressure sensor.6. A malfunctioning EGR valve.7. Excessive oil consumption.8. Possible engine misfire.9. The NOx sensor part number is incorrect.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6458 PID: SPN: 3216 FMI: 2/20 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6246 PID: SPN: 5709 FMI: 11/11 Aftertreatment 1 Outlet NOx Sensor Self-Diagnosis Trigger – Root Cause Not Known
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5991 PID: SPN: 102 FMI: 2/21 Intake Manifold 1 Pressure – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5989 PID: SPN: 102 FMI: 2/20 Intake Manifold 1 Pressure – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5943 PID: SPN: 103 FMI: 7/7 Engine Turbocharger 1 Speed – Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5936 PID: SPN: 4334 FMI: 0/15 Aftertreatment 1 Diesel Exhaust Fluid Pressure – Data Valid But Above Normal Operating Range – Least Severe Level

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6461 PID: SPN: 3216 FMI: 2/2 Aftertreatment 1 Intake NOx – Data Erratic, Intermittent, or Incorrect

Lamp:None

Reason:An incorrect NOx sensor reading has been detected by the aftertreatment intake NOx sensor.

Effect:None on performance.

Circuit Description:The aftertreatment intake NOx (Nitrogen Oxides) sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component Location:The aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the Diagnostics:This diagnostic runs when the aftertreatment diesel oxidation catalyst intake temperature is above 150°C [302°F], and the engine is in a motoring condition.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the aftertreatment outlet NOx sensor reading was not changing with engine conditions or is stuck.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. To validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using the recommended diagnostic tool or equivalent.2. The aftertreatment diesel oxidation catalyst intake temperature must be above 150°C [302°F] for 5 minutes before the aftertreatment intake NOx sensor can run its internal diagnostics.3. Vary engine speed by 100 RPM for until the fault clears (may take up to 10 min).4. The fault code status displayed by the recommended diagnostics tool or equivalent will change to inactive immediately after the diagnostic runs and passes.5. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.6. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.7. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. Malfunctioning aftertreatment intake NOx sensor.2. Improperly installed aftertreatment intake NOx sensor.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6459 PID: SPN: 3216 FMI: 2/21 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6458 PID: SPN: 3216 FMI: 2/20 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6246 PID: SPN: 5709 FMI: 11/11 Aftertreatment 1 Outlet NOx Sensor Self-Diagnosis Trigger – Root Cause Not Known
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5991 PID: SPN: 102 FMI: 2/21 Intake Manifold 1 Pressure – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5989 PID: SPN: 102 FMI: 2/20 Intake Manifold 1 Pressure – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5943 PID: SPN: 103 FMI: 7/7 Engine Turbocharger 1 Speed – Mechanical System Not Responding or Out of Adjustment

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6463 PID: SPN: 3226 FMI: 2/21 Aftertreatment 1 Outlet NOx Sensor – Data Not Rational – Drifted Low

Lamp:None

Reason:An offset in the outlet NOx sensor reading has been detected.

Effect:None on performance.

Circuit Description:The aftertreatment outlet NOx (Nitrogen Oxides) sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component Location:The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the Selective Catalytic Reduction (SCR) catalyst.

Conditions for Running the Diagnostics:This diagnostic runs when the aftertreatment SCR outlet temperature is above 200°C [392°F], and the engine is in a motoring condition.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the aftertreatment outlet NOx sensor was not reading zero while in a motoring (non-fueling) condition.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. Start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using the recommended diagnostic tool or equivalent.2. The aftertreatment SCR outlet temperature must be above 200°C [392°F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.3. To validate the repair, it is necessary to drive the vehicle and operate it in a motoring condition for 10 seconds continuously.4. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.5. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.6. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.7. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. Malfunctioning aftertreatment outlet NOx sensor.2. Diesel exhaust fluid crystallization or deposits.3. Improperly installed aftertreatment outlet NOx sensor.4. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.5. For intermittent power supply and datalink. communication issues with aftertreatment components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6461 PID: SPN: 3216 FMI: 2/2 Aftertreatment 1 Intake NOx – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6459 PID: SPN: 3216 FMI: 2/21 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6458 PID: SPN: 3216 FMI: 2/20 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6246 PID: SPN: 5709 FMI: 11/11 Aftertreatment 1 Outlet NOx Sensor Self-Diagnosis Trigger – Root Cause Not Known
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5991 PID: SPN: 102 FMI: 2/21 Intake Manifold 1 Pressure – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5989 PID: SPN: 102 FMI: 2/20 Intake Manifold 1 Pressure – Data Not Rational – Drifted High

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6485 PID: SPN: 4375 FMI: 2/2 Aftertreatment 1 Diesel Exhaust Fluid Pump Drive Percentage – Data Erratic, Intermittent, or Incorrect

Lamp:Amber

Reason:The diesel exhaust fluid pressure sensor has reported a reading too high or low for the operating conditions.

Effect:Possible reduced engine performance.

Circuit Description:The diesel exhaust fluid dosing unit lines are responsible for transporting diesel exhaust fluid between the dosing unit, dosing valve, and diesel exhaust fluid tank.

Component Location:There are three diesel exhaust fluid lines. One line is between the dosing unit and dosing valve, and the other two lines are between the dosing unit and the diesel exhaust fluid tank. These lines can be partially hidden from view by the SCR system and other vehicle components. Line routing will vary, based on the aftertreatment architecture and the OEM.

Conditions for Running the Diagnostics:This diagnostic runs when the SCR system is trying to prime.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid pressure was less than a threshold.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.2. Engine torque will be severely reduced.3. Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault Code:1. To validate the repair, perform the “aftertreatment diesel exhaust fluid system leak test” found under “ECM diagnostic tests” in the recommended diagnostic tool or equivalent.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.5. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. Low aftertreatment diesel exhaust fluid level in the diesel exhaust fluid tank.2. The line heaters are not successfully thawing the frozen diesel exhaust fluid.3. The diesel exhaust fluid pressure line between the dosing unit and dosing valve is kinked, broken, or disconnected.4. The diesel exhaust fluid suction line between the diesel exhaust fluid tank and the dosing unit is kinked, broken, or disconnected.5. Malfunctioning diesel exhaust fluid dosing unit.6. The diesel exhaust fluid suction and return lines between the dosing unit and diesel exhaust fluid tank are reversed.7. Debris from the diesel exhaust fluid tank. If debris is found in the diesel exhaust fluid tank, clean the diesel exhaust fluid tank thoroughly and fill with certified diesel exhaust fluid.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6463 PID: SPN: 3226 FMI: 2/21 Aftertreatment 1 Outlet NOx Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6461 PID: SPN: 3216 FMI: 2/2 Aftertreatment 1 Intake NOx – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6459 PID: SPN: 3216 FMI: 2/21 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6458 PID: SPN: 3216 FMI: 2/20 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6246 PID: SPN: 5709 FMI: 11/11 Aftertreatment 1 Outlet NOx Sensor Self-Diagnosis Trigger – Root Cause Not Known
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 5991 PID: SPN: 102 FMI: 2/21 Intake Manifold 1 Pressure – Data Not Rational – Drifted Low

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6486 PID: SPN: 4331 FMI: 0/16 Aftertreatment 1 Diesel Exhaust Fluid Actual Dosing Quantity – Data Valid But Above Normal Operating Range – Moderately Severe Level

Lamp:Amber

Reason:High aftertreatment diesel exhaust fluid flow detected.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment diesel exhaust fluid dosing valve is controlled by the ECM. When the Engine Control Module (ECM) commands DEF dosing, the ECM sends a Pulse-Width Modulated (PWM) signal to the dosing valve, which opens the dosing valve and allows DEF to be sprayed into the exhaust stream.

Component Location:1. The aftertreatment diesel exhaust fluid dosing unit location is Original Equipment Manufacturer (OEM) dependent.2. The aftertreatment diesel exhaust fluid dosing valve is installed in the exhaust system. It is mounted directly to the aftertreatment decomposition tube, before the Selective Catalytic Reduction (SCR) catalyst. Installation position will vary, based on the aftertreatment architecture and the Original Equipment Manufacturer (OEM).

Conditions for Running the Diagnostics:This diagnostic runs when the diesel exhaust fluid dosing valve is being commanded on.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid dosing performance is high.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. To validate the repair, perform the “aftertreatment diesel exhaust fluid doser pump override test” found under “ECM diagnostic tests” in the recommended diagnostic tool or equivalent.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.5. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. A malfunctioning aftertreatment diesel exhaust fluid dosing unit.2. A malfunctioning aftertreatment diesel exhaust fluid dosing valve.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6485 PID: SPN: 4375 FMI: 2/2 Aftertreatment 1 Diesel Exhaust Fluid Pump Drive Percentage – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6463 PID: SPN: 3226 FMI: 2/21 Aftertreatment 1 Outlet NOx Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6461 PID: SPN: 3216 FMI: 2/2 Aftertreatment 1 Intake NOx – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6459 PID: SPN: 3216 FMI: 2/21 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6458 PID: SPN: 3216 FMI: 2/20 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6246 PID: SPN: 5709 FMI: 11/11 Aftertreatment 1 Outlet NOx Sensor Self-Diagnosis Trigger – Root Cause Not Known

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6721 PID: SPN: 5569 FMI: 0/16 Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal Temperature – Data Valid But Above Normal Operating Range – Moderately Severe Level

Lamp:Amber

Reason:High internal temperature detected in the aftertreatment diesel particulate filter soot sensor module.

Effect:None on performance.

Circuit Description:The aftertreatment particulate matter sensor is a smart device and communicates with the Engine Control Module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component Location:The aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the Selective Catalytic Reduction (SCR) catalyst.

Conditions for Running the Diagnostics:This diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault Code:The aftertreatment diesel particulate filter soot sensor module reported the internal circuit board temperature was too high.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. To validate the repair, start the engine and let it idle for 1 minute.2. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.5. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:This fault code indicates the internal temperature of the aftertreatment diesel particulate filter soot sensor module was too high. Troubleshoot the exhaust system for leaks, missing heat shields, or dirt and debris that could lead to overheating of the aftertreatment diesel particulate filter soot sensor module.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6486 PID: SPN: 4331 FMI: 0/16 Aftertreatment 1 Diesel Exhaust Fluid Actual Dosing Quantity – Data Valid But Above Normal Operating Range – Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6485 PID: SPN: 4375 FMI: 2/2 Aftertreatment 1 Diesel Exhaust Fluid Pump Drive Percentage – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6463 PID: SPN: 3226 FMI: 2/21 Aftertreatment 1 Outlet NOx Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6461 PID: SPN: 3216 FMI: 2/2 Aftertreatment 1 Intake NOx – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6459 PID: SPN: 3216 FMI: 2/21 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6458 PID: SPN: 3216 FMI: 2/20 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted High

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6737 PID: SPN: 521026 FMI: 12/12 Route Parameter Manager Module Software Malfunction – Bad Intelligent Device Or Component

Lamp:None

Reason:An internal error of the route parameter manager module has been detected.

Effect:Predictive cruise control will not operate. Standard cruise control may not operate.

Circuit Description:The route parameter manager is the predictive cruise control system. The predictive cruise control system sends commands to the ECM via the vehicle J1939 network. Predictive cruise control dynamically adjust the vehicle speed profile while the vehicle is operating in cruise control. The vehicle speed profile is optimized for fuel economy based on the upcoming road grade.

Component Location:The SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the Diagnostics:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Code:The route parameter manager reported an internal error of the route parameter manager module.

Action Taken When the Fault Code is Active:The predictive cruise control will not operate.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 2 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.

Shop Talk:Possible causes of this fault code include:A malfunctioning route parameter manager module.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6721 PID: SPN: 5569 FMI: 0/16 Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal Temperature – Data Valid But Above Normal Operating Range – Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6486 PID: SPN: 4331 FMI: 0/16 Aftertreatment 1 Diesel Exhaust Fluid Actual Dosing Quantity – Data Valid But Above Normal Operating Range – Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6485 PID: SPN: 4375 FMI: 2/2 Aftertreatment 1 Diesel Exhaust Fluid Pump Drive Percentage – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6463 PID: SPN: 3226 FMI: 2/21 Aftertreatment 1 Outlet NOx Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6461 PID: SPN: 3216 FMI: 2/2 Aftertreatment 1 Intake NOx – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6459 PID: SPN: 3216 FMI: 2/21 Aftertreatment 1 Intake NOx Sensor – Data Not Rational – Drifted Low

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6738 PID: SPN: 521031 FMI: 3/3 Route Parameter Manager Module – Voltage Above Normal, Or Shorted To High Source

Lamp:None

Reason:An internal error of the route parameter manager module has been detected.

Effect:Predictive cruise control will not operate. Standard cruise control may not operate.

Circuit Description:The route parameter manager is the predictive cruise control system. The predictive cruise control system sends commands to the ECM via the vehicle J1939 network. Predictive cruise control dynamically adjust the vehicle speed profile while the vehicle is operating in cruise control. The vehicle speed profile is optimized for fuel economy based on the upcoming road grade.

Component Location:The SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the Diagnostics:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Code:The route parameter manager reported an internal error of the route parameter manager module.

Action Taken When the Fault Code is Active:The predictive cruise control will not operate.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 2 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.

Shop Talk:Possible causes of this fault code include:A malfunctioning route parameter manager module.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6737 PID: SPN: 521026 FMI: 12/12 Route Parameter Manager Module Software Malfunction – Bad Intelligent Device Or Component
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6721 PID: SPN: 5569 FMI: 0/16 Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal Temperature – Data Valid But Above Normal Operating Range – Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6486 PID: SPN: 4331 FMI: 0/16 Aftertreatment 1 Diesel Exhaust Fluid Actual Dosing Quantity – Data Valid But Above Normal Operating Range – Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6485 PID: SPN: 4375 FMI: 2/2 Aftertreatment 1 Diesel Exhaust Fluid Pump Drive Percentage – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6463 PID: SPN: 3226 FMI: 2/21 Aftertreatment 1 Outlet NOx Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6461 PID: SPN: 3216 FMI: 2/2 Aftertreatment 1 Intake NOx – Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6739 PID: SPN: 521031 FMI: 4/4 Route Parameter Manager Module – Voltage Below Normal, Or Shorted To Low Source

Lamp:None

Reason:An internal error of the route parameter manager module has been detected.

Effect:Predictive cruise control will not operate. Standard cruise control may not operate.

Circuit Description:The route parameter manager is the predictive cruise control system. The predictive cruise control system sends commands to the ECM via the vehicle J1939 network. Predictive cruise control dynamically adjust the vehicle speed profile while the vehicle is operating in cruise control. The vehicle speed profile is optimized for fuel economy based on the upcoming road grade.

Component Location:The SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the Diagnostics:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Code:The route parameter manager reported an internal error of the route parameter manager module.

Action Taken When the Fault Code is Active:The predictive cruise control will not operate.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 2 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.

Shop Talk:Possible causes of this fault code include:A malfunctioning route parameter manager module.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6738 PID: SPN: 521031 FMI: 3/3 Route Parameter Manager Module – Voltage Above Normal, Or Shorted To High Source
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6737 PID: SPN: 521026 FMI: 12/12 Route Parameter Manager Module Software Malfunction – Bad Intelligent Device Or Component
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6721 PID: SPN: 5569 FMI: 0/16 Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal Temperature – Data Valid But Above Normal Operating Range – Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6486 PID: SPN: 4331 FMI: 0/16 Aftertreatment 1 Diesel Exhaust Fluid Actual Dosing Quantity – Data Valid But Above Normal Operating Range – Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6485 PID: SPN: 4375 FMI: 2/2 Aftertreatment 1 Diesel Exhaust Fluid Pump Drive Percentage – Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6463 PID: SPN: 3226 FMI: 2/21 Aftertreatment 1 Outlet NOx Sensor – Data Not Rational – Drifted Low

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6741 PID: SPN: 521027 FMI: 14/14 Route Parameter Manager Module CAN 1 Malfunction – Special Instructions

Lamp:None

Reason:An internal error of the route parameter manager module has been detected.

Effect:Predictive cruise control will not operate. Standard cruise control may not operate.

Circuit Description:The route parameter manager is the predictive cruise control system. The predictive cruise control system sends commands to the ECM via the vehicle J1939 network. Predictive cruise control dynamically adjust the vehicle speed profile while the vehicle is operating in cruise control. The vehicle speed profile is optimized for fuel economy based on the upcoming road grade.

Component Location:The SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the Diagnostics:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Code:The route parameter manager reported an internal error of the route parameter manager module.

Action Taken When the Fault Code is Active:The predictive cruise control will not operate.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 2 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.

Shop Talk:Possible causes of this fault code include:A malfunctioning route parameter manager module.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6739 PID: SPN: 521031 FMI: 4/4 Route Parameter Manager Module – Voltage Below Normal, Or Shorted To Low Source
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6738 PID: SPN: 521031 FMI: 3/3 Route Parameter Manager Module – Voltage Above Normal, Or Shorted To High Source
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6737 PID: SPN: 521026 FMI: 12/12 Route Parameter Manager Module Software Malfunction – Bad Intelligent Device Or Component
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6721 PID: SPN: 5569 FMI: 0/16 Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal Temperature – Data Valid But Above Normal Operating Range – Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6486 PID: SPN: 4331 FMI: 0/16 Aftertreatment 1 Diesel Exhaust Fluid Actual Dosing Quantity – Data Valid But Above Normal Operating Range – Moderately Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6485 PID: SPN: 4375 FMI: 2/2 Aftertreatment 1 Diesel Exhaust Fluid Pump Drive Percentage – Data Erratic, Intermittent, or Incorrect

Read more →