Cumminz

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5792 PID: SPN: 7321 FMI: 4 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesAn internal circuit error was detected in the aftertreatment particulate sensor assembly

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensor

Possible Cause:1) Battery failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5716 PID: SPN: 3610 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5715 PID: SPN: 3251 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Differential Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5689 PID: SPN: 3226 FMI: 11 Aftertreatment 1 Outlet Nox Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5655 PID: SPN: 4364 FMI: 31 Aftertreatment 1 SCR Conversion Efficiency- condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5584 PID: SPN: 6773 FMI: 7 Aftertreatment 1 Particulate Sensor Regeneration Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5583 PID: SPN: 6777 FMI: 10 Aftertreatment 1 Particulate Sensor Detection Status- Abnormal Rate of Change

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5793 PID: SPN: 7323 FMI: 3 Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesAn internal circuit error was detected in the aftertreatment particulate sensor assembly

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensor

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5792 PID: SPN: 7321 FMI: 4 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5716 PID: SPN: 3610 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5715 PID: SPN: 3251 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Differential Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5689 PID: SPN: 3226 FMI: 11 Aftertreatment 1 Outlet Nox Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5655 PID: SPN: 4364 FMI: 31 Aftertreatment 1 SCR Conversion Efficiency- condition Exists
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5584 PID: SPN: 6773 FMI: 7 Aftertreatment 1 Particulate Sensor Regeneration Status- Mechanical System Not Responding or Out of Adjustment

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5837 PID: SPN: 5835 FMI: 21 Aftertreatment 1 Particulate Sensor- Data Not Rational- Drifted Low

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatement particulate matter sensor has detected the probe temperature value is not changing with conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensor

Possible Cause:1) Aftertreatment particulate sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5793 PID: SPN: 7323 FMI: 3 Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5792 PID: SPN: 7321 FMI: 4 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5716 PID: SPN: 3610 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5715 PID: SPN: 3251 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Differential Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5689 PID: SPN: 3226 FMI: 11 Aftertreatment 1 Outlet Nox Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5655 PID: SPN: 4364 FMI: 31 Aftertreatment 1 SCR Conversion Efficiency- condition Exists

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 584 PID: SID 39 SPN: 677 FMI: 3 Starter Relay Driver Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe starter lockout relay is controlled by the engine control module (ECM) through the starter lockout relay signal circuit. The relay prevents the starter from being engaged when the engine is running. The relay return circuit is dependent on OEM wiring. It can be wired back to the ECM on some vehicles or wired to chassis or block ground on others. Consult the OEM wiring diagram for return circuit details. The starter lockout relay circuit utilizes a pulse width modulated (PWM) signal. A PWM signal is a pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

Component LocationThe starter lockout relay is installed by the vehicle OEM. Refer to the OEM service manual for component location.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and when the pulse width modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the starter lockout relay pulse width modulated (PWM) signal was NOT at system voltage when the pulse width modulated (PWM) signal was commanded ON.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The Starter Lockout feature will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe ECM monitors the voltage level on this circuit. If it detects a voltage when the signal is commanded off, it records this fault code. This fault code can be caused by:

Open circuit in the starter lockout relay, OEM harness, or connectorsShort circuit to a voltage source in the OEM harness or relay.This fault can also be set active if the over crank protection feature (starter lockout) is enabled, but the engine/ECM is not wired to support it.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Starter Lockout relay failure2) OEM harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 559 PID: PID 157 SPN: 157 FMI: 18 Injector Metering Rail 1 Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 556 PID: PID 101 SPN: 101 FMI: 0 Crankcase Pressure- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 555 PID: PID 101 SPN: 101 FMI: 16 Crankcase Pressure- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 553 PID: PID 157 SPN: 157 FMI: 16 Injector Metering Rail 1 Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 516 PID: SID 232 SPN: 3514 FMI: 4 Sensor Supply 6 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 515 PID: SID 232 SPN: 3514 FMI: 3 Sensor Supply 6 Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 585 PID: SID 39 SPN: 677 FMI: 4 Starter Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe starter lockout relay is controlled by the engine control module (ECM) through the starter lockout relay signal circuit. The relay prevents the starter from being engaged when the engine is running. The relay return circuit is dependent on OEM wiring. It can be wired back to the ECM on some vehicles or wired to chassis or block ground on others. Consult the OEM wiring diagram for return circuit details. The starter lockout relay circuit utilizes a pulse width modulated (PWM) signal. A PWM signal is a pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

Component LocationThe starter lockout relay is installed by the vehicle OEM. Refer to the OEM service manual for component location.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and when the pulse width modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the starter lockout relay pulse width modulated (PWM) signal was at system voltage when the pulse width modulated (PWM) signal was commanded OFF.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The Starter Lockout feature will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe ECM monitors the voltage level on this circuit. If it detects a low voltage when the signal is commanded ON, it records this fault code. This fault code can be caused by a short circuit to ground in the starter lockout relay, OEM harness, or connectors.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Starter Lockout relay failure2) OEM harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 584 PID: SID 39 SPN: 677 FMI: 3 Starter Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 559 PID: PID 157 SPN: 157 FMI: 18 Injector Metering Rail 1 Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 556 PID: PID 101 SPN: 101 FMI: 0 Crankcase Pressure- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 555 PID: PID 101 SPN: 101 FMI: 16 Crankcase Pressure- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 553 PID: PID 157 SPN: 157 FMI: 16 Injector Metering Rail 1 Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 516 PID: SID 232 SPN: 3514 FMI: 4 Sensor Supply 6 Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5868 PID: SPN: 4339 FMI: 7 Aftertreatment 1 SCR Feedback Control Status- Mechanical System Not Responding or Out of Adjustment

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

The aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic has to meet specific engine and aftertreatment conditions to run and complete.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the adjusted aftertreatment diesel exhaust fluid dosing command has reached a maximum limit.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeIt is necessary to use the “Reset All Faults” command in INSITE™ electronic service tool to clear this fault and extinguish the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL).

Shop TalkTroubleshoot other active SCR related faults before this fault.

Possible Cause:1) N/A

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5837 PID: SPN: 5835 FMI: 21 Aftertreatment 1 Particulate Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5793 PID: SPN: 7323 FMI: 3 Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5792 PID: SPN: 7321 FMI: 4 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5716 PID: SPN: 3610 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5715 PID: SPN: 3251 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Differential Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5689 PID: SPN: 3226 FMI: 11 Aftertreatment 1 Outlet Nox Sensor- Root Cause Not Known

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5879 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe engine control module (ECM) controls the engine intake air throttle actuator. The ECM can open and close the throttle based on the operating condtions in order to regulate air flow to the engine.

Component LocationThe engine intake air throttle actuator is mounted in the piping between the charge air cooler and intake manifold.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine intake air throttle actuator signal is shorted to voltage when the actuator is commanded OFF.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine intake air throttle actuation will be disabled. The engine intake air throttle will default to the open position.

Exhaust Gas Recirculation (EGR) valve operation will be disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for up to 5 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

An open or short circuit to battery in the engine harness.A malfunctioning engine intake air throttle actuator

Possible Cause:1) Intake throttle actuator assembly failure2) Engine harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5868 PID: SPN: 4339 FMI: 7 Aftertreatment 1 SCR Feedback Control Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5837 PID: SPN: 5835 FMI: 21 Aftertreatment 1 Particulate Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5793 PID: SPN: 7323 FMI: 3 Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5792 PID: SPN: 7321 FMI: 4 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5716 PID: SPN: 3610 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5715 PID: SPN: 3251 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Differential Pressure- Abnormal Rate of Change

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5881 PID: SPN: 3464 FMI: 4 Electronic Throttle Control Actuator Driver Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe engine control module (ECM) controls the engine intake air throttle actuator. The ECM can open and close the throttle based on the operating condtions in order to regulate air flow to the engine.

Component LocationThe engine intake air throttle actuator is mounted in the piping between the charge air cooler and intake manifold.

Conditions for Running the DiagnosticsThis diagnostic runs when the engine intake air throttle actuator is being commanded ON.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine intake air throttle actuator signal is shorted to ground when the actuator is commanded ON.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine intake air throttle actuation will be disabled. The engine intake air throttle will default to the open position.

Exhaust Gas Recirculation (EGR) valve operation will be disabled.Diesel exhaust fluid injection into the aftertreatment system is disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 5 minutes. After 5 minutes, shut OFF the engine, perform a key cycle, and leave the key in the ON position for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A short circuit to ground in the engine harnessA malfunctioning engine intake air throttle actuator

Possible Cause:1) Engine Intake throttle actuator failure2) Engine harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5879 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5868 PID: SPN: 4339 FMI: 7 Aftertreatment 1 SCR Feedback Control Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5837 PID: SPN: 5835 FMI: 21 Aftertreatment 1 Particulate Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5793 PID: SPN: 7323 FMI: 3 Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5792 PID: SPN: 7321 FMI: 4 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5716 PID: SPN: 3610 FMI: 10 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure- Abnormal Rate of Change

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5882 PID: SPN: 3464 FMI: 7 Electronic Throttle Control Actuator- Mechanical System Not Responding or Out of Adjustment

Circuit DescriptionThe engine control module (ECM) controls the engine intake air throttle actuator. The ECM can open and close the throttle based on the operating condtions in order to regulate air flow to the engine.

Component LocationThe engine intake air throttle actuator is mounted in the piping between the charge air cooler and intake manifold.

Conditions for Running the DiagnosticsOne part runs when the keyswitch is initially turned ON before the engine is startedConditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine intake air throttle actuator failed the autozero span check.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Engine intake air throttle actuation will be disabled. The engine intake air throttle will default to the open position.

Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeStart and idle the engine for 1 minuteTurn the key switch OFF and allow the ECM to completely powerdown.Turn the key switch ON.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning engine intake air throttle actuator

Possible Cause:1) Engine harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5881 PID: SPN: 3464 FMI: 4 Electronic Throttle Control Actuator Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5879 PID: SPN: 3464 FMI: 3 Electronic Throttle Control Actuator Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5868 PID: SPN: 4339 FMI: 7 Aftertreatment 1 SCR Feedback Control Status- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5837 PID: SPN: 5835 FMI: 21 Aftertreatment 1 Particulate Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5793 PID: SPN: 7323 FMI: 3 Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5792 PID: SPN: 7321 FMI: 4 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 595 PID: PID 103 SPN: 103 FMI: 16 Turbocharger 1 Speed- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe turbocharger speed sensor is a variable reluctance speed sensor. It consists of a coil of wire and an iron core. The target on the turbocharger shaft is a ground flat in the center of the shaft. As the flat on the turbocharger shaft spins past the speed sensor, a signal is generated. The Engine Control Module (ECM) interprets this signal and converts it to a turbocharger speed reading.

Component LocationThe turbocharger speed sensor is mounted in the center housing of the turbocharger.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the turbocharger speed was greater than 150,000 rpm for more than 5 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.The ECM will estimate the turbocharger speed.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Damaged turbocharger speed sensorDamaged engine harnessDamaged ECM.If the fault occurs intermittently, look for causes of intermittent open or short circuits in the turbocharger speed sensor circuit (including the speed sensor pigtail connector).

Possible Cause:1) Turbocharger speed sensor failure2) Engine harness, Connector(s)3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 585 PID: SID 39 SPN: 677 FMI: 4 Starter Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 584 PID: SID 39 SPN: 677 FMI: 3 Starter Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 559 PID: PID 157 SPN: 157 FMI: 18 Injector Metering Rail 1 Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 556 PID: PID 101 SPN: 101 FMI: 0 Crankcase Pressure- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 555 PID: PID 101 SPN: 101 FMI: 16 Crankcase Pressure- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 553 PID: PID 157 SPN: 157 FMI: 16 Injector Metering Rail 1 Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level

Read more →