Skip to content Skip to side menu

Cumminz

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4745 PID: SPN: 3515 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2- Root Cause Not Known

Circuit DescriptionThe DEF quality sensor is a smart device and communicates with the engine electronic control module (ECM) via the J1939 data link. The DEF quality sensor receives power and ground directly from the battery. The sensor performs its own internal diagnostics and reports malfunctions back to the primary engine ECM via the J1939 data link. The DEF quality sensor is used to measure the concentration of the DEF in the tank.

Component LocationThe aftertreatment diesel exhaust fluid quality sensor is located in the aftertreatment diesel exhaust fluid tank. It may be a combination sensor with the aftertreatement diesel exhaust fluid tank level and tank temperature sensors. Location of the tank and sensor is OEM dependant. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThis fault code is triggered when the DEF quality sensor detects that the internal temperature has exceeded 125°C.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.This fault code can not be cleared with INSITE™ electronic service tool.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment diesel exhaust fluid tank temperature sensor

Possible Cause:1) Aftertreatment DEF tank level/quality/temperature sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4739 PID: SPN: 1761 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4737 PID: SPN: 3031 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4732 PID: SPN: 1761 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4731 PID: SPN: 3031 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4728 PID: SPN: 1209 FMI: 18 Exhaust Gas Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4727 PID: SPN: 157 FMI: 15 Injector Metering rail 1 Pressure- Data Valid But Above Normal Operating Range- Least Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4747 PID: SPN: 3217 FMI: 20 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted High

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR outlet temperature has been above 200°C [392° F] for a calibratible period of time while the engine is running.

Conditions for Setting the Fault CodesThe ECM detected that the absolute difference between the inlet and outlet NOx sensors was greater than a calibrated threshold.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment SCR outlet temperature must be above 200° C [392° F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Malfunctioning aftertreatment intake NOx sensorDiesel exhaust fluid crystallization or depositsImproperly installed aftertreatment intake NOx sensor.Exhaust system leaks.Exhaust gas recirculation (EGR) system leaks can also cause this fault code. Inspect the EGR bellows and EGR connections for signs of leaks.

Leaks in the air intake system between the turbocharger and intake manifold

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment intake NOx sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4745 PID: SPN: 3515 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4739 PID: SPN: 1761 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4737 PID: SPN: 3031 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4732 PID: SPN: 1761 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4731 PID: SPN: 3031 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4728 PID: SPN: 1209 FMI: 18 Exhaust Gas Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4748 PID: SPN: 3217 FMI: 21 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted Low

Circuit DescriptionThe aftertreatment intake NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment intake NOx sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment intake NOx sensor is used to measure the NOx emissions at the intake of the aftertreatment system.

Component LocationThe aftertreatment intake NOx sensor is mounted on the engine near the turbocharger turbine outlet.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR outlet temperature has been above 200°C [392° F] for a calibratible period of time while the engine is running.

Conditions for Setting the Fault CodesThe ECM detected that the absolute difference between the inlet and outlet NOx sensors was greater than a calibrated threshold.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment SCR outlet temperature must be above 200° C [392° F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Malfunctioning aftertreatment intake NOx sensorDiesel exhaust fluid crystallization or depositsImproperly installed aftertreatment intake NOx sensor.Exhaust system leaks.Exhaust gas recirculation (EGR) system leaks can also cause this fault code. Inspect the EGR bellows and EGR connections for signs of leaks.

Leaks in the air intake system between the turbocharger and intake manifold

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment Intake NOx sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4747 PID: SPN: 3217 FMI: 20 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4745 PID: SPN: 3515 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4739 PID: SPN: 1761 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4737 PID: SPN: 3031 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4732 PID: SPN: 1761 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4731 PID: SPN: 3031 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor- Out of Calibration

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4749 PID: SPN: 3227 FMI: 20 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted High

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR outlet temperature is above 200°C [392°F], and the engine is in a motoring condition.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment outlet NOx sensor was not reading zero while in a motoring (non-fueling) condition.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment SCR outlet temperature must be above 200° C [392° F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Malfunctioning aftertreatment outlet NOx sensorDiesel exhaust fluid crystallization or depositsImproperly installed aftertreatment outlet NOx sensor.Exhaust system leaks.Exhaust gas recirculation (EGR) system leaks can also cause this fault code. Inspect the EGR bellows and EGR connections for signs of leaks.

Leaks in the air intake system between the turbocharger and intake manifold

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment Outlet NOx sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4748 PID: SPN: 3217 FMI: 21 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4747 PID: SPN: 3217 FMI: 20 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4745 PID: SPN: 3515 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4739 PID: SPN: 1761 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4737 PID: SPN: 3031 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4732 PID: SPN: 1761 FMI: 13 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Out of Calibration

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4751 PID: SPN: 3227 FMI: 21 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted Low

Circuit DescriptionThe aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the aftertreatment SCR outlet temperature is above 200°C [392°F], and the engine is in a motoring condition.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment outlet NOx sensor was not reading zero while in a motoring (non-fueling) condition.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.The aftertreatment SCR outlet temperature must be above 200° C [392° F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Malfunctioning aftertreatment outlet NOx sensorDiesel exhaust fluid crystallization or depositsImproperly installed aftertreatment outlet NOx sensor.Exhaust system leaks.Exhaust gas recirculation (EGR) system leaks can also cause this fault code. Inspect the EGR bellows and EGR connections for signs of leaks.

Leaks in the air intake system between the turbocharger and intake manifold

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Cause:1) Aftertreatment outlet NOx sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4749 PID: SPN: 3227 FMI: 20 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4748 PID: SPN: 3217 FMI: 21 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4747 PID: SPN: 3217 FMI: 20 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4745 PID: SPN: 3515 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4739 PID: SPN: 1761 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4737 PID: SPN: 3031 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature- Root Cause Not Known

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4768 PID: SPN: 3521 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Property- Root Cause Not known

Circuit DescriptionThe DEF quality sensor is a smart device and communicates with the engine electronic control module (ECM) via the J1939 data link. The DEF quality sensor receives power and ground directly from the battery. The sensor performs its own internal diagnostics and reports malfunctions back to the primary engine ECM via the J1939 data link. The DEF quality sensor is used to measure the concentration of the DEF in the tank.

Component LocationThe aftertreatment diesel exhaust fluid quality sensor is located in the aftertreatment diesel exhaust fluid tank. It may be a combination sensor with the aftertreatement diesel exhaust fluid tank level and tank temperature sensors. Location of the tank and sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThe diagnostic runs continuously when the following conditions are met:

Keyswitch is in the ON position or when the engine is running.Ambient temperature is above -20°C [-4°F].Vehicle altitude change is less than 305 m [1000 ft] in 1 hour.Conditions for Setting the Fault CodesThe DEF quality sensor has detected that the DEF concentration has fallen below a critical threshold.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Diesel exhaust fluid injection into the aftertreatment system is disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Degraded, diluted, or incorrect diesel exhaust fluidMalfunctioning Aftertreatment DEF Quality Sensor.

Possible Cause:1) DEF fluid2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4751 PID: SPN: 3227 FMI: 21 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4749 PID: SPN: 3227 FMI: 20 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4748 PID: SPN: 3217 FMI: 21 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4747 PID: SPN: 3217 FMI: 20 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4745 PID: SPN: 3515 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2- Root Cause Not Known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4739 PID: SPN: 1761 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Root Cause Not Known

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4769 PID: SPN: 1761 FMI: 10 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Abnormal Rate of Change

Circuit DescriptionThe aftertreatment diesel exhaust fluid tank level sensor is used to monitor the aftertreatment diesel exhaust fluid level inside the aftertreatment diesel exhaust fluid tank.

Component LocationThe aftertreatment diesel exhaust fluid tank level sensor is located in the aftertreatment diesel exhaust fluid tank. Location of the tank and level sensor is OEM dependent. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThe diagnostic runs continuously when the following conditions are met:

Keyswitch is in the ON position or when the engine is running.Ambient temperature is above -20°C [-4°F].Vehicle altitude change is less than 305 m [1000 ft] in 1 hour.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank level sensor reading was invalid for an extended period of time.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment diesel exhaust fluid tank level sensorTampering of the aftertreatment diesel exhaust fluid tank level sensor

Possible Cause:1) Aftertreatment DEF tank level/temperature/quality sensor failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4768 PID: SPN: 3521 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Property- Root Cause Not known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4751 PID: SPN: 3227 FMI: 21 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4749 PID: SPN: 3227 FMI: 20 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4748 PID: SPN: 3217 FMI: 21 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4747 PID: SPN: 3217 FMI: 20 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4745 PID: SPN: 3515 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2- Root Cause Not Known

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 483 PID: PID 129 SPN: 1349 FMI: 3 Injector Metering rail 2 Pressure Sensor Circuit- Voltage Above Normal, or Shorted to High Source

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the fuel rail pressure sensor using a dedicated sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The fuel rail pressure sensor provides a primary fuel pressure signal to the ECM on the fuel rail pressure sensor signal 1 circuit. The sensor also provides a secondary fuel pressure sensor signal on the fuel rail pressure signal 2 circuit. This sensor signal voltage changes based on the pressure in the fuel rail. The ECM will detect a high signal voltage at high rail pressure conditions. The ECM will detect a low signal voltage during low rail pressure conditions.

Component LocationThe high-pressure fuel pump is mounted to the gear housing. The fuel pump actuator is mounted on the fuel pump. The fuel pressure sensor is mounted in the high pressure fuel rail. The fuel pressure relief valve is mounted on the high pressure fuel rail.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the fuel rail pressure 2 signal voltage was greater than 4.75-VDC for more than 3 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning fuel rail pressure sensorA short circuit to battery in the engine harness.An open return circuit in the engine harnessAn open circuit in the engine harness

Possible Cause:1) ECM failure2) Engine harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 452 PID: PID 157 SPN: 157 FMI: 3 Injector Metering Rail 1 Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 451 PID: SPN: 157 FMI: 3 Injector Metering Rail 1 Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 442 PID: PID 168 SPN: 168 FMI: 16 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 441 PID: PID 168 SPN: 168 FMI: 18 Battery 1 Voltage- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 436 PID: PID 105 SPN: 105 FMI: 2 Intake Manifold 1 Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 435 PID: PID 100 SPN: 100 FMI: 2 Engine Oil Rifle Pressure- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4839 PID: SPN: 3667 FMI: 31 Engine Air Shutoff- Condition Exists

Circuit DescriptionThe engine control module (ECM) controls the engine intake air throttle actuator. The ECM can open and close the throttle based on the operating condtions in order to regulate air flow to the engine.

Component LocationThe engine intake air throttle actuator is mounted in the piping between the charge air cooler and intake manifold.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected active Engine Intake Air Throttle faults.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis is an information only fault that sets when there are one or more active Engine Intake Air Throttle faults when the Engine Intake Air Throttle has been configured as an Air Shutoff.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4769 PID: SPN: 1761 FMI: 10 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4768 PID: SPN: 3521 FMI: 11 Aftertreatment 1 Diesel Exhaust Fluid Property- Root Cause Not known
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4751 PID: SPN: 3227 FMI: 21 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4749 PID: SPN: 3227 FMI: 20 Aftertreatment Outlet Oxygen- Data Not Rational- Drifted High
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4748 PID: SPN: 3217 FMI: 21 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted Low
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4747 PID: SPN: 3217 FMI: 20 Aftertreatment Intake Oxygen Sensor- Data Not Rational- Drifted High

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 484 PID: PID 129 SPN: 1349 FMI: 4 Injector Metering Rail 2 Pressure Sensor Circuit- Voltage Below Normal, or Shorted to Low Source

Circuit DescriptionThe engine control module (ECM) provides a 5 volt supply to the fuel rail pressure sensor using a dedicated sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The fuel rail pressure sensor provides a primary fuel pressure signal to the ECM on the fuel rail pressure sensor signal 1 circuit. The sensor also provides a secondary fuel pressure sensor signal on the fuel rail pressure signal 2 circuit. This sensor signal voltage changes based on the pressure in the fuel rail. The ECM will detect a high signal voltage at high rail pressure conditions. The ECM will detect a low signal voltage during low rail pressure conditions.

Component LocationThe high-pressure fuel pump is mounted to the gear housing. The fuel pump actuator is mounted on the fuel pump. The fuel pressure sensor is mounted in the high pressure fuel rail. The fuel pressure relief valve is mounted on the high pressure fuel rail.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the fuel rail pressure 2 signal voltage was less than 0.25-VDC for more than 3 seconds.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning fuel rail pressure sensorA short circuit to ground in the engine harness

Possible Cause:1) ECM failure2) Engine harness

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 483 PID: PID 129 SPN: 1349 FMI: 3 Injector Metering rail 2 Pressure Sensor Circuit- Voltage Above Normal, or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 452 PID: PID 157 SPN: 157 FMI: 3 Injector Metering Rail 1 Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 451 PID: SPN: 157 FMI: 3 Injector Metering Rail 1 Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 442 PID: PID 168 SPN: 168 FMI: 16 Battery 1 Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 441 PID: PID 168 SPN: 168 FMI: 18 Battery 1 Voltage- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 436 PID: PID 105 SPN: 105 FMI: 2 Intake Manifold 1 Temperature- Data Erratic, Intermittent, or Incorrect

Read more →