Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is initially turned to the ON position.

The keyswitch must be turned OFF for more than 30 seconds before this diagnostic will run at initial key ON.

Conditions for Setting the Fault CodesThe Variable Geometry Turbocharger (VGT) actuator position was not known during initial power ON.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.

VGT actuation will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the keyswitch in the ON position for 1 minute. Note that the keyswitch must be completely turned OFF for more than 30 seconds before this diagnostic will run at initial key ON.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code can only be logged after the VGT actuator has been removed or replaced, and then not installed correctly. The gear alignment between the actuator and the turbocharger housing is misaligned. The correct installation procedure must be followed when replacing the VGT actuator.

Possible Cause:1) Turbocharger failure2) VGT Actuator failure3) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2398 PID: SPN: 171 FMI: 2 Ambient Air Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2387 PID: SID 27 SPN: 641 FMI: 7 VGT Actuator Driver Circuit (Motor)- Mechanical System Not Responding or Out Of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2377 PID: SID 33 SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2376 PID: PID 412 SPN: 412 FMI: 4 Exhaust Gas Recirculation Temperature Sensor Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 245 PID: SID 33 SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe fan control circuit is a device used by the engine to control the fan operation. When the engine control module (ECM) energizes the fan control circuit, the engine fan is engaged.

The fan control circuit utilizes a pulse width modulated (PWM) signal. A PWM signal is a pulsed voltage signal between 0-VDC and system voltage. The frequency of the pulsed voltage signal is dependent on the application requirement.

There are two types of fans supported by the fan control circuit; variable speed and ON/OFF. INSITE™ electronic service tool can be used to determine which fan type is presently set up for use. The fan control circuit varies by the OEM. OEMs can use a solenoid return that is wired to the ECM or use a return that goes to engine block or chassis ground.

Component LocationThe control solenoid location varies by OEM. Refer to the appropriate OEM service manual to determine the location.

Conditions for Running the DiagnosticsThis diagnostic runs when the keyswitch is in the ON position and when the pulse width modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the fan control circuit pulse width modulated (PWM) signal was not at system voltage when the pulse width modulated (PWM) signal was commanded ON.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.Fan operation will be disabled.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe fan control logic can be adjusted with INSITE™ electronic service tool. There are two choices: 12 or 24 volts ON, or 0 volts ON. For proper fan operation, the fan control logic setup with INSITE™ electronic service tool must match the hardware configuration on the vehicle.

This fault code is logged when the ECM commands 12 or 24-VDC to the fan control solenoid, but the voltage on the fan control signal circuit is less than 12 or 24-VDC. The low voltage on the signal circuit usually indicates a short circuit to ground in the harness or solenoid.

If Fault Code 245 is still active after completing the following troubleshooting steps, consult the OEM service manual for procedures to check the fan control circuit for a short circuit to ground.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) Fan Control solenoid failure2) OEM harness3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 242 PID: PID 84 SPN: 84 FMI: 10 Wheel-Based Vehicle Speed Sensor Circuit Tampering Has Been Detected- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 241 PID: PID 84 SPN: 84 FMI: 2 Wheel-Based Vehicle Speed- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 239 PID: SID 232 SPN: 3511 FMI: 3 Sensor Supply 3 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 238 PID: PID 105 SPN: 3511 FMI: 4 Sensor Supply 3 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 235 PID: PID 111 SPN: 111 FMI: 1 Coolant Level- Data Valid But Below Normal Operational Range- Most Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 234 PID: PID 190 SPN: 190 FMI: 0 Engine Crankshaft Speed/Position- Data Valid But Above Normal Operating Range- Most Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe exhaust gas temperature is calculated by the engine control module (ECM). The exhaust gas temperature is derived by the ECM, based on engine operating conditions such as intake manifold air temperature, engine speed, injection timing, intake manifold pressure, and fuel flow.

Component LocationThere is not a physical exhaust gas temperature sensor in the system. The exhaust gas temperature is a calculation of exhaust gas temperature before the turbocharger, and is also known as turbine intake temperature.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) calculated turbine inlet temperature was greater than a calibratible value.

Action Taken When the Fault Code is ActiveThe ECM logs the fault code immediately when the diagnostic runs and fails.Fuel is limited in an attempt to decrease the exhaust gas temperature entering the turbocharger.Conditions for Clearing the Fault CodeTo validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.To validate the repair using a Chassis Dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe most common cause of this fault code is low boost pressure. Low boost pressure can be caused by several factors: leaking charge-air cooler, damaged charge-air cooler piping or hose, loose charge-air cooler clamps, damaged intake manifold pressure sensor, damaged variable geometry turbocharger, damaged turbocharger control valve, or damaged turbocharger control shutoff valve.

This fault code can also be caused by a turbocharger fuel control derate, which can be viewed with INSITE™ electronic service tool, under the Engine Operating State. Turbocharger fuel control derates can be caused by several factors: high exhaust temperatures, turbocharger compressor inlet temperatures, and turbocharger compressor outlet temperatures.

Exhaust gas recirculation (EGR) system leaks can also cause this fault code. Inspect the EGR bellows and EGR connections for signs of leaks.

Note: This fault code will most likely not be active with no load in the shop. The engine must be loaded to trip this fault code, and to determine if the cause has been found and repaired. Running units on the dynamometer can sometimes cause this fault code to log, due to the stationary nature and high temperatures.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2398 PID: SPN: 171 FMI: 2 Ambient Air Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2387 PID: SID 27 SPN: 641 FMI: 7 VGT Actuator Driver Circuit (Motor)- Mechanical System Not Responding or Out Of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2377 PID: SID 33 SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level

Circuit DescriptionThe air shutoff valve is an optional component used to shutdown the engine in the event of an engine overspeed condition. It can be closed via a manual shutdown switch or via an ECM command.

Component LocationThe engine air shutoff valve location can vary depending on the OEM. Refer to the OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine speed was greater than 2500 RPM for 0.25 seconds, or the operator manually tripped the engine air shutoff valve.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.The air shutoff valve closesThe engine will be shut down.

Conditions for Clearing the Fault CodeThe air shutoff valve must be reset to the open position.To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code indicates that the engine has been shut down via the engine air shutoff valve. This can occur automatically (engine overspeed condition) or manually (activating the engine air shutoff valve switch in the cab). In either case, this fault code will become active until the valve de-activated.

Possible Cause:1) Engine damage2) Crankshaft engine speed sensor, or Camshaft engine position sensor3) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2398 PID: SPN: 171 FMI: 2 Ambient Air Temperature- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2387 PID: SID 27 SPN: 641 FMI: 7 VGT Actuator Driver Circuit (Motor)- Mechanical System Not Responding or Out Of Adjustment

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 249 PID: PID 171 SPN: 171 FMI: 3 Ambient Air Temperature Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source

Circuit DescriptionThe ambient air temperature sensor is a variable resistor sensor and is used to measure the temperature of the ambient air. The engine control module (ECM) uses this temperature reading to optimize engine performance, and determine if heating of the SCR system is required. The engine control module (ECM) supplies 5 volts to the ambient air temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the ambient air temperature.

Component LocationThe mounting location for the ambient air temperature sensor is OEM dependent. Refer to the appropriate OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the ambient air temperature signal voltage was out of range high.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.A default value for the ambient air temperature reading is used.Active and stationary regeneration of the diesel particulate filter will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Open return circuit in the harness, connectors, or sensorOpen signal circuit or shorted to a voltage source.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM harness2) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 245 PID: SID 33 SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 242 PID: PID 84 SPN: 84 FMI: 10 Wheel-Based Vehicle Speed Sensor Circuit Tampering Has Been Detected- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 241 PID: PID 84 SPN: 84 FMI: 2 Wheel-Based Vehicle Speed- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 239 PID: SID 232 SPN: 3511 FMI: 3 Sensor Supply 3 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 238 PID: PID 105 SPN: 3511 FMI: 4 Sensor Supply 3 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 235 PID: PID 111 SPN: 111 FMI: 1 Coolant Level- Data Valid But Below Normal Operational Range- Most Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe exhaust gas pressure sensor is used to measure exhaust gas pressure in the exhaust manifold. This information is used by the engine control module (ECM) to control emissions and exhaust gas recirculation (EGR) valve operation. The ECM provides a 5 volt supply to the exhaust gas pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The exhaust gas pressure sensor provides a signal to the ECM on the exhaust gas pressure sensor signal circuit. This sensor signal voltage changes, based on the pressure in the exhaust manifold.

Component LocationThe exhaust gas pressure sensor is located above the front section of the exhaust manifold and is plumbed into the exhaust manifold.

Conditions for Running the DiagnosticsThis diagnostic consists of two parts:

One part runs immediately after the keyswitch is turned OFF, and the engine coolant temperature is above 70°C or 158°F.

The second part runs continuously while the engine is running.Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the exhaust pressure reading was higher or lower than the other absolute pressure sensors when the keyswitch is OFF and the engine is not running.The Engine Control Module (ECM) detected the exhaust pressure was higher or lower than expected during normal engine operation.Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.A default value is used for the exhaust gas pressure sensor reading.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, first ensure the engine coolant temperature is above 70°C or 158°F. Operate the engine if necessary.Cycle the keyswitch to the ON position for 30 seconds, then cycle the keyswitch to the OFF position for 30 seconds. Start the engine and run it at high idle for up to 5 minutes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

Stuck in-range exhaust gas pressure sensor readingHigh resistance in the exhaust gas pressure sensor signal or return linesPlugging or restriction in the exhaust gas pressure sensor tubeLeaks in the exhaust system

Possible Cause:1) Engine harness2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2398 PID: SPN: 171 FMI: 2 Ambient Air Temperature- Data Erratic, Intermittent, or Incorrect

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2555 PID: S70 SPN: 729 FMI: 3/3 Engine Intake Air Heater 1 Circuit – Voltage Above Normal or Shorted to High Source

Lamp:Amber

Reason:High voltage detected at the intake air heater signal circuit.

Effect:The intake air heaters can be ON or OFF all the time.

Circuit Description:The intake air heater improves starting and white smoke control in cold ambient conditions. The Engine Control Module (ECM) controls relays that switch power to the intake air heater. Air heaters on 12 volt systems will have two relays while 24 volt systems only require one relay.

Component Location:The intake air heater is located at the air inlet connection to the intake manifold. The location of the intake air heater relays will vary by vehicle and engine configuration.

Conditions for Running the Diagnostics:This diagnostic runs when the keyswitch is in the ON position and when the Pulse-Width Modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the intake air heater circuit Pulse-Width Modulated (PWM) signal was greater than 0-VDC when the PWM signal was turned off by the ECM.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.2. The intake air heater operation will be disabled.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.2. The fault code status displayed by the diagnostic tool will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after four consecutive trips where the diagnostic runs and passes.5. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. Intake air heater relay signal wire not connected to the relay.2. Intake air heater relay return wire not connected to the relay.3. Open circuit in the intake air heater relay signal wire.4. Open circuit in the intake air heater relay return wire.5. Intake air heater signal wire shorted to a voltage source.

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2368 PID: S82 SPN: 1112 FMI: 3/3 Engine Brake Actuator Driver 3 Circuit – Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2365 PID: S82 SPN: 1112 FMI: 4/4 Engine Brake Actuator Driver Output 3 Circuit – Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 383 PID: S70 SPN: 729 FMI: 5/5 Engine Intake Air Heater 1 Circuit – Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6766 PID: SPN: 3521 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Property- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6765 PID: SPN: 3521 FMI: 16 Aftertreatment 1 Diesel Exhaust Fluid Property- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6735 PID: SPN: 5569 FMI: 16 Aftertreatment 1 Diesel Particulate Filter 1 Soot Sensor ECU Internal Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2556 PID: S70 SPN: 729 FMI: 4/4 Engine Intake Air Heater 1 Circuit – Voltage Below Normal or Shorted to Low Source

Lamp:Amber

Reason:Low voltage detected at the intake air heater signal circuit.

Effect:The intake air heaters can be ON or OFF all the time.

Circuit Description:The intake air heater improves starting and white smoke control in cold ambient conditions. The Engine Control Module (ECM) controls relays that switch power to the intake air heater. Air heaters on 12 volt systems will have two relays while 24 volt systems only require one relay.

Component Location:The intake air heater is located at the air inlet connection to the intake manifold. The location of the intake air heater relays will vary by vehicle and engine configuration.

Conditions for Running the Diagnostics:This diagnostic runs when the keyswitch is in the ON position and when the Pulse-Width Modulated (PWM) device is getting energized or de-energized. In some cases, the diagnostics can also run at some fixed intervals.

Conditions for Setting the Fault Codes:The Engine Control Module (ECM) detected the intake air heater circuit Pulse-Width Modulated (PWM) signal was not system voltage when the PWM signal was on.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.2. The intake air heater operation will be disabled.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.2. The fault code status displayed by the diagnostic tool will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after four consecutive trips where the diagnostic runs and passes.5. The reset all faults command in the diagnostic tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. A shorted intake air heater relay.2. Intake air heater relay supply wire shorted to ground.

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2555 PID: S70 SPN: 729 FMI: 3/3 Engine Intake Air Heater 1 Circuit – Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2368 PID: S82 SPN: 1112 FMI: 3/3 Engine Brake Actuator Driver 3 Circuit – Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2365 PID: S82 SPN: 1112 FMI: 4/4 Engine Brake Actuator Driver Output 3 Circuit – Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 383 PID: S70 SPN: 729 FMI: 5/5 Engine Intake Air Heater 1 Circuit – Current Below Normal or Open Circuit
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6766 PID: SPN: 3521 FMI: 18 Aftertreatment 1 Diesel Exhaust Fluid Property- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6765 PID: SPN: 3521 FMI: 16 Aftertreatment 1 Diesel Exhaust Fluid Property- Data Valid But Above Normal Operating Range- Moderately Severe Level

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 256 PID: PID 171 SPN: 171 FMI: 4 Ambient Air Temperature Sensor 1 Circuit- Voltage Below Normal or Shorted to Low Source

Circuit DescriptionThe ambient air temperature sensor is a variable resistor sensor and is used to measure the temperature of the ambient air. The engine control module (ECM) uses this temperature reading to optimize engine performance, and determine if heating of the SCR system is required. The engine control module (ECM) supplies 5 volts to the ambient air temperature signal circuit. The ECM monitors the change in voltage caused by changes in the resistance of the sensor to determine the ambient air temperature.

Component LocationThe mounting location for the ambient air temperature sensor is OEM dependent. Refer to the appropriate OEM service manual.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the ambient air temperature signal voltage was out of range low.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.A default value for the ambient air temperature reading is used.Active and stationary regeneration of the diesel particulate filter will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, and leave the key in the ON position for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThe ambient air temperature sensor shares return wires in the engine harness with other sensors. Opens and shorts in the engine harness can cause multiple fault codes to be active. Check fault codes with multiple counts first.

Possible causes of this fault code include:

Signal shorted to ground in the harnessSignal shorted to return or ground in the sensor.Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

Possible Cause:1) OEM harness2) ECM failure

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 249 PID: PID 171 SPN: 171 FMI: 3 Ambient Air Temperature Sensor 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 245 PID: SID 33 SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 242 PID: PID 84 SPN: 84 FMI: 10 Wheel-Based Vehicle Speed Sensor Circuit Tampering Has Been Detected- Abnormal Rate of Change
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 241 PID: PID 84 SPN: 84 FMI: 2 Wheel-Based Vehicle Speed- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 239 PID: SID 232 SPN: 3511 FMI: 3 Sensor Supply 3 Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 238 PID: PID 105 SPN: 3511 FMI: 4 Sensor Supply 3 Circuit- Voltage Below Normal or Shorted to Low Source

Read more →

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2634 PID: SID 027 SPN: 641 FMI: 12 VGT Actuator Controller- Bad Intelligent Device or Component

Circuit DescriptionThe variable geometry turbocharger (VGT) is electronically activated by the VGT actuator. The VGT actuator is a smart device and receives information via the J1939 data link from the primary engine control module (ECM). The VGT actuator performs its own diagnostics and reports malfunctions back to the primary engine ECM, using the J1939 data link. The ECM then decodes the error message and converts it to a fault code.

Component LocationThe VGT actuator is located on the turbocharger bearing housing.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Variable Geometry Turbocharger (VGT) detected an internal error in the VGT smart device.

Action Taken When the Fault Code is ActiveThe ECM illuminates the red STOP ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.

VGT actuation will be disabled.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the red STOP ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code is logged when the VGT smart actuator detected an internal error within the VGT actuator. The VGT actuator will stop controlling the turbocharger when this fault code is active.

Fault Code 2634 will become active if the VGT actuator is removed from the turbocharger and then the keyswitch is turned to the ON position; or it may be possible for it to become active if the actuator fails the install/calibrate procedure. If this occurs, disconnect the VGT actuator from the engine harness with the keyswitch ON, and connect the VGT actuator to the engine harness. Fault Code 2634 should go inactive. Follow the VGT actuator installation procedure to install the VGT actuator.

Possible Cause:1) VGT actuator failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2554 PID: PID 131 SPN: 1209 FMI: 2 Exhaust Gas Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2468 PID: PID 190 SPN: 102 FMI: 3 Engine Crankshaft Speed/Position- Data valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2451 PID: SID 384 SPN: 2789 FMI: 16 Turbocharger Turbine Intake Temperature- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2449 PID: SID 027 SPN: 641 FMI: 13 VGT Actuator Controller- Out of Calibration
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2448 PID: PID 2560 SPN: 111 FMI: 17 Coolant Level- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 2416 PID: SID 253 SPN: 1634 FMI: 13 Engine Control Module Calibration Memory Checksum- Out of Calibration

Read more →