Skip to content

Telegram : @Diezel365

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 649 PID: SID 115 SPN: 1378 FMI: 31 Engine Oil Change Interval- Condition Exists

Circuit DescriptionThe engine control module (ECM) informs the driver of a maintenance event by using the Maintenance Monitor feature’s lubrication oil drain limits.

Component LocationNot Applicable

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the engine oil and filter required changing based on the programmable setting in the Maintenance Monitor.

Action Taken When the Fault Code is ActiveThe ECM flashes the amber CHECK ENGINE lamp, indicating a maintenance condition, immediately after the diagnostic runs and fails.Conditions for Clearing the Fault CodeUse the INSITE electronic service tool to reset the Maintenance Monitor feature.

The ECM will turn off the flashing amber CHECK ENGINE lamp / MAINTENANCE lamp immediately after the diagnostic runs and passes.

The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code will only become active if the Maintenance Monitor is enabled in INSITE™ electronic service tool. Make sure the oil and filter are changed before clearing the fault code.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 629 PID: PID 314 SPN: 1176 FMI: 18 Turbocharger 1 Compressor Inlet Pressure- Data Valid But Below Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 597 PID: PID 167 SPN: 167 FMI: 18 Electrical Charging System Voltage- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 596 PID: PID 167 SPN: 167 FMI: 16 Electrical Charging System Voltage- Data Valid But Above Normal Operational Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 595 PID: PID 103 SPN: 103 FMI: 16 Turbocharger 1 Speed- Data Valid But Above Normal Operating Range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 585 PID: SID 39 SPN: 677 FMI: 4 Starter Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source