Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6267 PID: SPN: 4360 FMI: 14 Aftertreatment 1 SCR Intake Temperature- Special Instructions

Circuit DescriptionThe aftertreatment SCR (selective catalytic reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component LocationThe aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs when the engine is running and exhaust flow is above a minimum level.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment SCR intermediate temperature sensor signal was irrational for more than 5 minutes.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Diesel exhaust fluid injection into the aftertreatment system is disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, it may be necessary to operate the vehicle on a chassis dynamometer or to drive the vehicle in order to get the engine load high enough for the diagnostic to run.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment SCR intermediate temperature sensorA malfunctioning aftertreatment SCR outlet temperature sensor

Possible Cause:1) Aftertreatment SCR temperature sensor module failure2) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6266 PID: SPN: 5862 FMI: 14 Aftertreatment 1 SCR Intermediate Gas Temperature- Special Instructions
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6265 PID: SPN: 3936 FMI: 7 Aftertreatment 1 Diesel Particulate Filter System- Mechanical System Not Responding or Out of Adjustment
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6264 PID: SPN: 647 FMI: 4 Fan Control Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6263 PID: SPN: 647 FMI: 3 Fan Control Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6262 PID: SPN: 677 FMI: 4 Engine Starter Motor Relay Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 6261 PID: SPN: 677 FMI: 3 Engine Starter Motor Relay Circuit- Voltage Above Normal or Shorted to High Source