Skip to content

Telegram : @Diezel365

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5583 PID: SPN: 6777 FMI: 10 Aftertreatment 1 Particulate Sensor Detection Status- Abnormal Rate of Change

Circuit DescriptionThe aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment particulate matter sensor performs internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The particulate matter sensor is permanently attached to the particulate matter control module. They are serviced as a single component and can not be replaced individually. The aftertreatment particulate matter sensor is used to measure the soot emissions at the outlet of the aftertreatment system.

Component LocationThe aftertreatment particulate matter sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the engine is running.

Conditions for Setting the Fault CodesThe aftertreatment particulate matter sensor reading was not valid.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes for this fault include:

Malfunctioning aftertreatment particulate matter sensorFor intermittent power supply and data link communication issues with aftertreatment components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing, or intermittent connections.

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5582 PID: SPN: 7854 FMI: 2 Aftertreatment 1 Particulate Sensor Module Battery Voltage Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5581 PID: SPN: 7329 FMI: 2 Aftertreatment 1 Particulate Sensor Heater Power Supply- Data Erratic, Intermittent, or Incorrect
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5579 PID: SPN: 6778 FMI: 16 Aftertreatment 1 Particulate Sensor Power Supply- Data Valid But Above Normal Operating range- Moderately Severe Level
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5578 PID: SPN: 6778 FMI: 4 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5577 PID: SPN: 6778 FMI: 3 Aftertreatment 1 Particulate Sensor Power Supply- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5383 PID: SPN: 3720 FMI: 15 Aftertreatment 1 Diesel Particulate Filter Ash Load Percent- Data valid But Above Normal Operating Range- Least Severe Level