Skip to content

Telegram : @Diezel365

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4157 PID: SPN: 4376 FMI: 7 Aftertreatment Diesel Exhaust Fluid Return Valve- Mechanical System Not Responding or Out of Adjustment

Circuit DescriptionThe aftertreatment diesel exhaust fluid return valve is used to purge the aftertreatment diesel exhaust fluid dosing system. When the return valve is energized, the dosing system will purge and return the aftertreatment diesel exhaust fluid to the tank.

Component LocationThe aftertreatment diesel exhaust fluid return valve is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic only runs when the aftertreatment diesel exhaust fluid dosing system is purging.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid pressure did not drop when the aftertreatment diesel exhaust fluid return valve was commanded on.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault CodeTo validate the repair, perform the “Aftertreatment Diesel Exhaust Fluid System Leak Test” found under “ECM Diagnostic Tests” in the INSITE™ electronic service tool

The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning aftertreatment diesel exhaust fluid return valve

Possible Cause:1) ECM calibration

Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4156 PID: SPN: 5746 FMI: 4 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Relay Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4155 PID: SPN: 5746 FMI: 3 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Relay Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4154 PID: SPN: 7323 FMI: 4 Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4153 PID: SPN: 7321 FMI: 3 Aftertreatment 1 Particulate Sensor Heater High Side Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4152 PID: SPN: 5743 FMI: 9 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module- Abnormal Update Rate
Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 4151 PID: SPN: 5742 FMI: 9 Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Abnormal Update Rate