Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1961 PID: SID 146 SPN: 2791 FMI: 15 EGR Valve Control Circuit Calculated Over Temperature- Data Valid But Above Normal Operational Range- Least Severe Level

Circuit DescriptionThe exhaust gas recirculation (EGR) valve is controlled by a brushless motor located on top of the EGR valve. The EGR valve motor uses three different motor legs to move the valve through its range of motion. The ECM uses the EGR motor A, B, and C wires to command the EGR valve to the appropriate position in order to meet EGR flow targets.The EGR valve motor contains three position sensors that detect the location of the EGR valve. These sensors report the position of the valve back to the ECM over the EGR valve position A, B, and C wires.

The EGR valve motor contains three position sensors that detect the location of the EGR valve. These sensors report the position of the valve back to the ECM over the EGR valve position A, B, and C wires.

Component LocationThe EGR valve device driver is internal to the ECM and can not be serviced separately.

Conditions for Running the DiagnosticsThis diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault CodesThe Engine Control Module (ECM) detected the temperature of the EGR valve driver internal to the ECM was greater than 150°C [302°F].

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.Active and stationary regeneration of the diesel particulate filter will be disabled.Exhaust Gas Recirculation (EGR) valve operation will be disabled.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkThis fault code may be inactive when the vehicle is in the shop because the EGR valve driver temperature has cooled down. Therefore, troubleshoot multiple inactive counts of this fault code as an active fault code.

Possible causes of this fault code include:

Malfunctioning ECM.

Possible Cause:1) ECM failure

Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1943 PID: SPN: 3555 FMI: 17 Ambient Air Density- Data Valid But Below Normal Operational Range- Least Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1942 PID: PID 101 SPN: 101 FMI: 2 Crankcase Pressure- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1938 PID: SID 212 SPN: 3597 FMI: 18 ECU Power Output Supply Voltage 1- Data Valid But Below Normal Operational Range- Moderately Severe Level
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1932 PID: SID 382 SPN: 3556 FMI: 2 Aftertreatment Doser- Data Erratic, Intermittent, or Incorrect
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1928 PID: SPN: 1928 FMI: 4 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Below Normal or Shorted to Low Source
Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 1927 PID: SPN: 3480 FMI: 3 Aftertreatment Fuel Pressure Sensor Circuit- Voltage Above Normal or Shorted to High Source