Skip to content

Telegram : @Diezel365

Cummins ISX11.9 CM2250 (2010-12) Fault Code: 1926 PID: SID 332 SPN: 3480 FMI: 2 Aftertreatment Fuel Pressure Sensor- Data Erratic, Intermittent, or Incorrect

Circuit DescriptionThe aftertreatment fuel pressure sensor is used to monitor the fuel pressure into the aftertreatment system. The electronic control module (ECM) supplies the aftertreatment fuel pressure sensor a 5 volt reference voltage. When the fuel pressure is low, the sensor signal voltage is low. When the fuel pressure is high, the sensor signal voltage is near the 5 volt reference voltage. The ECM monitors the aftertreatment fuel pressure signal circuit voltage to calculate the pressure of the fuel within the aftertreatment system.

Component LocationThe aftertreatment fuel pressure sensor is located in the aftertreatment shutoff valve assembly.

Conditions for Running the DiagnosticsThis diagnostic runs during active regeneration of the aftertreatment diesel particulate filter.

Conditions for Setting the Fault CodesThe ECM detects that the aftertreatment fuel pressure sensor is reading an erratic value, or the aftertreatment fuel pressure reading is not changing with the engine operating conditions.

Action Taken When the Fault Code is ActiveThe ECM illuminates the amber CHECK ENGINE lamp and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.A calculated value of aftertreatment fuel pressure is used for aftertreatment operation.Active regeneration of the aftertreatment diesel particulate filter will be disabled unitl the next key cycle.Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.Conditions for Clearing the Fault CodeTo validate the repair, perform INSITE? electronic service tool Aftertreatment Diesel Particulate Filter Regeneration Test. Once the temperatures in the aftertreatment are warm enough to inject diesel fuel into the exhaust, the diagnostic will run.The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.For OBD engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop TalkPossible causes of this fault code include:

A malfunctioning in-range aftertreatment fuel pressure sensorA plugged fuel filterA malfunctioning fuel pump gear pump.

Possible Cause:1) ECM failure

Cummins ISX11.9 CM2250 (2010-12) Fault Code: 1925 PID: SID 334 SPN: 3482 FMI: 2 Aftertreatment Fuel Shutoff Valve 1- Data Erratic, Intermittent, or Incorrect
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 1924 PID: SID 334 SPN: 3482 FMI: 4 Aftertreatment Fuel Shutoff Valve 1 Circuit- Voltage Below Normal or Shorted to Low Source
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 1923 PID: SID 334 SPN: 3482 FMI: 3 Aftertreatment Fuel Shutoff Valve 1 Circuit- Voltage Above Normal or Shorted to High Source
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 1922 (X) PID: SID 324 SPN: 3251 FMI: 0 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 1922 (BCL) PID: SID 324 SPN: 3251 FMI: 0 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Most Severe Level
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 1921 (X) PID: SID 324 SPN: 3251 FMI: 16 Aftertreatment Diesel Particulate Filter Differential Pressure- Data Valid But Above Normal Operating Range- Moderately Severe Level