Cummins ISB6.7 CM2150 (2007-09) Fault Code: 442 PID: 168 SPN: 168 FMI: 0 Battery 1 Voltage – Data Valid but Above Normal Operational Range – Moderately Severe Level. ECM supply voltage is above the maximum system voltage level.
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
This fault code is logged when the ECM battery supply voltage exceed 36-VDC. Causes of this fault code include:
1)Faulty alternator or regulator that is overcharging the system 2)Batteries connected in series instead of parallel
Possible repairs:
1)Install the battery system correctly. 2)Repair or replace the alternator, regulator, and/or the OEM wiring to the alternator.