The aftertreatment control module (ACM) uses the aftertreatment diesel exhaust fluid (DEF) dosing pressure sensor value to adjust and maintain DEF pressure at the DEF dosing valve by controlling DEF pump speed. If the pressure decreases below expected value when the pump is in initial pressure build-up mode or if the pressure increases above expected value when pump is in idle speed mode, the ACM considers DEF pressure outside of normal operating range and indicates a malfunction in a DEF dosing pressure sensor.

Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A137:7 is above normal value

Observable symptoms
1) No aftertreatment diesel exhaust fluid (DEF) dosage

Probable cause
1) Short circuit to voltage supply, Control wire (-)
2) Short circuit to 5V, Control wire (-)
3) Wiring harness
4) Aftertreatment Diesel Exhaust Fluid (DEF) Pump
5) Aftertreatment Control Module (ACM)

Detailed information
1) Possible engine de-rate

Volvo All Engines (2013 Emissions) Fault Code: P205C00 PID: ACM Aftertreatment Reagent Tank Temperature Short Circuit Low
Volvo All Engines (2013 Emissions) Fault Code: P204A13 PID: ACM Reductant Pressure Sensor
Volvo All Engines (2013 Emissions) Fault Code: P204A01 PID: ACM Reductant Pressure Sensor
Volvo All Engines (2013 Emissions) Fault Code: P204800 PID: ACM Aftertreatment Reagent Dosing Valve Short Circuit Low
Volvo All Engines (2013 Emissions) Fault Code: P204713 PID: ACM Reductant Injection Valve Control Bank 1 Unit 1
Volvo All Engines (2013 Emissions) Fault Code: P204364 PID: ACM Aftertreatment Reagent Tank Temperature Sensor Stuck