PACCAR PX-8 CM2150 (2007-09) Fault Code: 296 PID: 223 SPN: 1388 FMI: 14 Auxiliary Pressure Sensor Input 1 – Special Instructions

Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM.

This fault code is activated when the pressure input from the OEM sensor exceeds the engine protection limit defined by the OEM. An engine power derate is possible depending on the OEM application.

Possible repairs:

1)Replace the OEM harness.
2)If necessary, recalibrate the ECM.

PACCAR PX-8 CM2150 (2007-09) Fault Code: 295 PID: 108 SPN: 108 FMI: 2 Barometric Pressure – Data Erratic, Intermittent, or Incorrect. The ambient air pressure sensor is reading an erratic value at initial key-on.
PACCAR PX-8 CM2150 (2007-09) Fault Code: 294 PID: 441 SPN: 441 FMI: 4 Auxiliary Temperature Sensor Input 1 Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at OEM auxiliary temperature circuit.
PACCAR PX-8 CM2150 (2007-09) Fault Code: 293 PID: 441 SPN: 441 FMI: 3 Auxiliary Temperature Sensor Input 1 Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage or open circuit detected at the OEM auxiliary temperature circuit.
PACCAR PX-8 CM2150 (2007-09) Fault Code: 292 PID: 441 SPN: 441 FMI: 14 Auxiliary Temperature Sensor Input 1 – Special Instructions.
PACCAR PX-8 CM2150 (2007-09) Fault Code: 288 PID: 372 SPN: 974 FMI: 2 AE J1939 Multiplexing Remote Accelerator Pedal or Lever Position Sensor System – Received Network Data In Error. The OEM vehicle electronic control unit (VECU) detected a fault with the remote accelerator.
PACCAR PX-8 CM2150 (2007-09) Fault Code: 287 PID: 91 SPN: 91 FMI: 2 E J1939 Multiplexed Accelerator Pedal or Lever Sensor System – Received Network Data In Error. The OEM vehicle electronic control unit (VECU) detected a fault with its accelerator pedal.