PACCAR PX-6 CM2150 (2007-09) Fault Code: 1877 PID: SPN: 3245 FMI: 4 Aftertreatment Exhaust Gas Temperature 3 Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
The aftertreatment diesel particulate filter outlet temperature sensor shares return wires in the OEM harness with other sensors. A shorted return can cause multiple fault codes to be active.
Possible causes:
1)Signal shorted to ground in the harness
2)Signal shorted to return or ground in the sensor.
Possible repairs:
1)Replace the aftertreatment diesel particulate filter outlet temperature sensor.
2)Replace the OEM harness.
3)Replace the aftertreatment harness.
4)Replace all interconnects.
5)Replace the ECM.
PACCAR PX-6 CM2150 (2007-09) Fault Code: 1876 PID: SPN: 3245 FMI: 3 Aftertreatment Exhaust Gas Temperature 3 Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage or open circuit detected at the aftertreatment diesel particulate filter outlet temperature sensor circuit.
PACCAR PX-6 CM2150 (2007-09) Fault Code: 1866 PID: 411 SPN: 411 FMI: 2 Exhaust Gas Recirculation Valve Delta Pressure – Data Erratic, Intermittent, or Incorrect. An error in the EGR delta pressure signal was detected at initial key-on or the sensor failed the autozero test.
PACCAR PX-6 CM2150 (2007-09) Fault Code: 1844 PID: 101 SPN: 101 FMI: 4 Crankcase Pressure Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the crankcase pressure circuit.
PACCAR PX-6 CM2150 (2007-09) Fault Code: 1843 PID: 101 SPN: 101 FMI: 3 Crankcase Pressure Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage detected at the crankcase pressure circuit.
PACCAR PX-6 CM2150 (2007-09) Fault Code: 1696 PID: SID 232 SPN: 3513 FMI: 4 Sensor Supply 5 – Voltage Below Normal or Shorted to Low Source. Low voltage detected at sensor supply number 5 circuit in the OEM harness.
PACCAR PX-6 CM2150 (2007-09) Fault Code: 1695 PID: SID 232 SPN: 3513 FMI: 3 Sensor Supply 5 – Voltage Above Normal or Shorted to High Source. High voltage detected at sensor supply number 5 circuit in the OEM harness.