Cummins ISX11.9 CM2250 (2010-12) Fault Code: 346 (MD) PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory Software- Bad Intelligent Device or Component

Circuit DescriptionThe Original Equipment Manufacturer (OEM) wiring harness connects multiple outputs or switched inputs to the ECM. They can be enabled or disabled using INSITE? electronic service tool, such as such as the accelerator interlock/engine torque limit switch or the clutch/engine protection override switch. Many of the outputs and switched inputs share a common wire on the OEM wiring harness. Refer to the engine wiring diagram to determine which features share common wires in the OEM harness.

Component LocationThe output or switched inputs to this diagnostic are found in the OEM harness.

Conditions for Running the DiagnosticsThis diagnostic runs at initial key ON only.

Conditions for Setting the Fault CodesThe ECM detects that features that share a common OEM harness input or output to the ECM are simultaneously enabled at the same time.

Action Taken When the Fault Code is ActiveThe ECM will set the fault code active immediately after the diagnostic is set. The features that are in conflict may not operate correctly.

Conditions for Clearing the Fault CodeTo validate the repair, start the engine and let it idle for 1 minute.The fault code status displayed by INSITE? electronic service tool will change to INACTIVE immediately after the conflicting features have been adjusted correctly and the diagnostic runs and passes.The ECM will turn off the amber CHECK ENGINE lamp after the diagnostic runs and passes.The ?Reset All Faults? command in INSITE? electronic service tool can be used to clear active and inactive faults.

Shop TalkIf two features that share a common OEM wire are enabled simultaneously in the ECM, this fault code will be logged. To disable the fault code, disable one of the features on the shared OEM wire. For example, if the accelerator interlock switch and powertrain protection torque limit switch are both enabled in the ECM, either disable one of the features with INSITE? electronic service tool or configure one of the features to be multiplexed using the SAE J1939 multiplexing feature.

Possible Cause:1) ECM Calibration

Cummins ISX11.9 CM2250 (2010-12) Fault Code: 346 (HD) PID: SID 253 SPN: 630 FMI: 12 Engine Control Module Calibration Memory Software- Bad Intelligent Device or Component
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 343 PID: SID 254 SPN: 629 FMI: 12 Electronic Control Module Warning Internal Hardware Failure- Bad Intelligent Device or Component
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 339 PID: SID 87 SPN: 1267 FMI: 4 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Below Normal or Shorted to Low Source
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 338 PID: SID 87 SPN: 1267 FMI: 3 Idle Shutdown Vehicle Accessories Relay Driver Circuit- Voltage Above Normal or Shorted to High Source
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 334 PID: 116 SPN: 110 FMI: 2 Engine Coolant Temperature- Data Erratic, Intermittent, or Incorrect
Cummins ISX11.9 CM2250 (2010-12) Fault Code: 332 PID: SID 4 SPN: 654 FMI: 5 Injector Solenoid Driver Cylinder 4 Circuit- Current Below Normal or Open Circuit