Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 2 Gear Position Sensor: Data Erratic

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Gear Position Sensor. The X-Y Gear Position Sensor reports fore-and-aft movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Gear Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 52 is set when TECU has detected either an electrical failure of the X-Y Gear Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Gear Position Sensor supply and the return voltage signal from the X-Y Gear Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU detects the X-Y Gear Position Sensor return voltage signal is outside of the 0.5–4.5-volt range for 1 second or longer

Fallback:
All FMIs:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 2: X-Y Gear Position Sensor return voltage signal stays within the 0.5–4.5-volt range for 1 second.

Possible Causes:
FMI 2, 4 or 7:
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Gear Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 7 Gear Position Sensor: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 4 Gear Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 3 Gear Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 2 Gear Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low

Read more →

Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 3 Gear Position Sensor: Voltage Above Normal or Shorted High

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Gear Position Sensor. The X-Y Gear Position Sensor reports fore-and-aft movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Gear Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 52 is set when TECU has detected either an electrical failure of the X-Y Gear Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Gear Position Sensor supply and the return voltage signal from the X-Y Gear Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 3 – Voltage Above Normal or Shorted High: TECU detects the X-Y Gear Position Sensor supply voltage has exceeded 5.25 volts for 1 second or longer.

Fallback:
All FMIs:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear

Conditions to Set Fault Code Inactive:
FMI 3, 4: Supply voltage stays within the 4.75–5.25-volt range for 1 second.

Possible Causes:
FMI 3:
1) TECU
– Internal failure
2) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to power

Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 2 Gear Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 7 Gear Position Sensor: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 4 Gear Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 3 Gear Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 2 Gear Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 10 Rail Position Sensor: Abnormal Rate of Change

Read more →

Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 4 Gear Position Sensor: Voltage Below Normal or Shorted Low

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Gear Position Sensor. The X-Y Gear Position Sensor reports fore-and-aft movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Gear Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 52 is set when TECU has detected either an electrical failure of the X-Y Gear Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Gear Position Sensor supply and the return voltage signal from the X-Y Gear Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 4 – Voltage Below Normal or Shorted Low: TECU detects the X-Y Gear Position Sensor supply voltage is below 4.75 volts for 1 second or longer.

Fallback:
All FMIs:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear

Conditions to Set Fault Code Inactive:
FMI 3, 4: Supply voltage stays within the 4.75–5.25-volt range for 1 second.

Possible Causes:
FMI 2, 4 or 7:
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Gear Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 3 Gear Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 2 Gear Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 7 Gear Position Sensor: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 4 Gear Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 3 Gear Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 2 Gear Position Sensor: Data Erratic

Read more →

Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 7 Gear Position Sensor: Mechanical System Not Responding

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Gear Position Sensor. The X-Y Gear Position Sensor reports fore-and-aft movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Gear Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 52 is set when TECU has detected either an electrical failure of the X-Y Gear Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Gear Position Sensor supply and the return voltage signal from the X-Y Gear Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 7 – Mechanical System Not Responding: The reported X-Y Gear Position Sensor return voltage signal is outside of the operating range physically allowed for 1 second or longer.

Fallback:
All FMIs:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 7: X-Y Gear Position Sensor return voltage signal returns within the physical operating range of the Shift Bar Housing.

Possible Causes:
FMI 2, 4 or 7:
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Gear Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 4 Gear Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 3 Gear Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 2 Gear Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 7 Gear Position Sensor: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 4 Gear Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 3 Gear Position Sensor: Voltage Above Normal or Shorted High

Read more →

Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 2 Gear Position Sensor: Data Erratic

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Gear Position Sensor. The X-Y Gear Position Sensor reports fore-and-aft movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Gear Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 52 is set when TECU has detected either an electrical failure of the X-Y Gear Position Sensor circuit
or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Gear Position Sensor supply and the return voltage signal from the X-Y Gear Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 2 – Data Erratic: TECU detects the X-Y Gear Position Sensor return voltage signal is outside of the 0.5–4.5-volt range for 1 second or longer

Fallback:
All FMIs:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 2: X-Y Gear Position Sensor return voltage signal stays within the 0.5–4.5-volt range for 1 second.

Possible Causes:
FMI 2, 4 or 7:
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Gear Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 2 Rail Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low

Read more →

Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 3 Gear Position Sensor: Voltage Above Normal or Shorted High

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Gear Position Sensor. The X-Y Gear Position Sensor reports fore-and-aft movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Gear Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 52 is set when TECU has detected either an electrical failure of the X-Y Gear Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Gear Position Sensor supply and the return voltage signal from the X-Y Gear Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 3 – Voltage Above Normal or Shorted High: TECU detects the X-Y Gear Position Sensor supply voltage has exceeded 5.25 volts for 1 second or longer.

Fallback:
All FMIs:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear

Conditions to Set Fault Code Inactive:
FMI 3, 4: Supply voltage stays within the 4.75–5.25-volt range for 1 second.

Possible Causes:
FMI 3:
1) TECU
– Internal failure
2) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to power

Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 2 Gear Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 2 Rail Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 51 PID: 60 SPN: FMI: 10 Rail Position Sensor: Abnormal Rate of Change

Read more →

Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 4 Gear Position Sensor: Voltage Below Normal or Shorted Low

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Gear Position Sensor. The X-Y Gear Position Sensor reports fore-and-aft movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Gear Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 52 is set when TECU has detected either an electrical failure of the X-Y Gear Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Gear Position Sensor supply and the return voltage signal from the X-Y Gear Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 4 – Voltage Below Normal or Shorted Low: TECU detects the X-Y Gear Position Sensor supply voltage is below 4.75 volts for 1 second or longer.

Fallback:
All FMIs:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear

Conditions to Set Fault Code Inactive:
FMI 3, 4: Supply voltage stays within the 4.75–5.25-volt range for 1 second.

Possible Causes:
FMI 2, 4 or 7:
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Gear Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 3 Gear Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 2 Gear Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 2 Rail Position Sensor: Data Erratic

Read more →

Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 7 Gear Position Sensor: Mechanical System Not Responding

Overview:
The Fuller Advantage X-Y Shifter is equipped with a Gear Position Sensor. The X-Y Gear Position Sensor reports fore-and-aft movement of the Shift Finger to the Transmission Electronic Control Unit (TECU) as a voltage signal. The X-Y Gear Position Sensor is connected to the TECU via the Transmission Harness. The TECU performs continuous diagnostics on the circuit to detect a shorted circuit, open circuit or incorrect position reading. Fault Code 52 is set when TECU has detected either an electrical failure of the X-Y Gear Position Sensor circuit or a mechanical failure within the X-Y Shifter.

Detection:
The TECU monitors both the 5-volt X-Y Gear Position Sensor supply and the return voltage signal from the X-Y Gear Position Sensor. If the system detects that either the supply voltage or return voltage is out of range, the fault code is set Active.

Conditions to Set Fault Code Active:
FMI 7 – Mechanical System Not Responding: The reported X-Y Gear Position Sensor return voltage signal is outside of the operating range physically allowed for 1 second or longer.

Fallback:
All FMIs:
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission remains in current gear.
• Until the fault becomes Inactive, driver may have to shut off engine with transmission in gear.

Conditions to Set Fault Code Inactive:
FMI 7: X-Y Gear Position Sensor return voltage signal returns within the physical operating range of the Shift Bar Housing.

Possible Causes:
FMI 2, 4 or 7:
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) X-Y Shifter
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
– Gear Position Sensor damaged
3) TECU
– Internal failure

Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 4 Gear Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 3 Gear Position Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 52 PID: 59 SPN: FMI: 2 Gear Position Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 10 Rail Position Sensor: Abnormal Rate of Change
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 4 Rail Position Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 51 PID: SPN: 60 FMI: 3 Rail Position Sensor: Voltage Above Normal or Shorted High

Read more →

Eaton Fuller Advantage (2017) Fault Code: 56 PID: SPN: 161 FMI: 2 Input Shaft Speed Sensor: Data Erratic

Overview
The Fuller Advantage transmission is equipped with electronic speed sensors. The Input Shaft, Main Shaft and Output Shaft Speed Sensors are used to calculate gear ratios within the transmission. The Input Shaft Speed Sensor measures the rotational speed of the Input Shaft, taken from the upper countershaft drive gear. The Main Shaft Speed Sensor measures the rotational speed of the transmission gearing exiting the main case, taken from the auxiliary upper countershaft gear. The Output Shaft Speed Sensor measures the rotational speed of the output shaft taken from the Output Shaft Tone Wheel. The Transmission Electronic Control Unit (TECU) compares these speeds to calculate the gear ratios of the main case, auxiliary case and overall transmission.

The Input Shaft Speed Sensor transmits a voltage signal to the TECU based on the rotational speed of the Input Shaft entering the transmission main case. The TECU compares Input Shaft Speed to Main Shaft Speed to confirm the gear ratio of the main case and compares Input Shaft Speed to Output Shaft Speed to confirm the overall transmission gear ratio.

Fault Code 56 indicates an electrical fault within the Input Shaft Speed Sensor circuit or a speed value that is inconsistent with the calculated gear ratios.

Detection:
The TECU monitors the Input Shaft Speed Sensor signal and compares the sensor readings with the Main Shaft Speed Sensor and the Output Shaft Speed Sensor to determine sensor validity. The TECU also monitors the Input Shaft Speed Sensor electrical circuit for any shorts to power, ground or open circuits.

Conditions to Set Fault Code Active:
The system can detect Input Shaft Speed Sensor faults when one of the following conditions is present for 1 second or longer:
FMI 2 – Data Erratic: TECU detects data being reported from the Input Shaft Speed Sensor does not match the current gear ratio in comparison with other sensors.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission will not engage a gear from neutral.
• Transmission may be limited to down shifts only.
• Transmission operates as normal until neutral gear selection is attained. Once in neutral, the transmission will not engage a start gear.

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid signal from the Input Shaft Speed Sensor and detects no electrical open or short circuits for 2 seconds.

Possible Causes:
All FMIs
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) Input Shaft Speed Sensor
– Internal failure
– Physical damage
3) Mechanical Transmission
– Internal transmission wear or damage

Eaton Fuller Advantage (2017) Fault Code: 56 PID: 161 SPN: FMI: 5 Input Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 56 PID: 161 SPN: FMI: 4 Input Shaft Speed Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 56 PID: 161 SPN: FMI: 3 Input Shaft Speed Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 56 PID: 161 SPN: FMI: 2 Input Shaft Speed Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 7 Gear Position Sensor: Mechanical System Not Responding
Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 4 Gear Position Sensor: Voltage Below Normal or Shorted Low

Read more →

Eaton Fuller Advantage (2017) Fault Code: 56 PID: SPN: 161 FMI: 3 Input Shaft Speed Sensor: Voltage Above Normal or Shorted High

Overview
The Fuller Advantage transmission is equipped with electronic speed sensors. The Input Shaft, Main Shaft and Output Shaft Speed Sensors are used to calculate gear ratios within the transmission. The Input Shaft Speed Sensor measures the rotational speed of the Input Shaft, taken from the upper countershaft drive gear. The Main Shaft Speed Sensor measures the rotational speed of the transmission gearing exiting the main case, taken from the auxiliary upper countershaft gear. The Output Shaft Speed Sensor measures the rotational speed of the output shaft taken from the Output Shaft Tone Wheel. The Transmission Electronic Control Unit (TECU) compares these speeds to calculate the gear ratios of the main case, auxiliary case and overall transmission.

The Input Shaft Speed Sensor transmits a voltage signal to the TECU based on the rotational speed of the Input Shaft entering the transmission main case. The TECU compares Input Shaft Speed to Main Shaft Speed to confirm the gear ratio of the main case and compares Input Shaft Speed to Output Shaft Speed to confirm the overall transmission gear ratio.

Fault Code 56 indicates an electrical fault within the Input Shaft Speed Sensor circuit or a speed value that is inconsistent with the calculated gear ratios.

Detection:
The TECU monitors the Input Shaft Speed Sensor signal and compares the sensor readings with the Main Shaft Speed Sensor and the Output Shaft Speed Sensor to determine sensor validity. The TECU also monitors the Input Shaft Speed Sensor electrical circuit for any shorts to power, ground or open circuits.

Conditions to Set Fault Code Active:
The system can detect Input Shaft Speed Sensor faults when one of the following conditions is present for 1 second or longer:
FMI 3 – Voltage Above Normal or Shorted High: TECU detects a short to power in the circuit.

Fallback:
All FMIs
• “F” flashes in gear display.
• Service light flashes (if equipped).
• Transmission will not engage a gear from neutral.
• Transmission may be limited to down shifts only.
• Transmission operates as normal until neutral gear selection is attained. Once in neutral, the transmission will not engage a start gear.

Conditions to Set Fault Code Inactive:
All FMIs: TECU receives a valid signal from the Input Shaft Speed Sensor and detects no electrical open or short circuits for 2 seconds.

Possible Causes:
All FMIs
1) Transmission Harness
– Bent, spread, corroded or loose terminals
– Wiring shorted to ground, shorted to power or open
2) Input Shaft Speed Sensor
– Internal failure
– Physical damage
3) Mechanical Transmission
– Internal transmission wear or damage

Eaton Fuller Advantage (2017) Fault Code: 56 PID: SPN: 161 FMI: 2 Input Shaft Speed Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 56 PID: 161 SPN: FMI: 5 Input Shaft Speed Sensor: Current Below Normal or Open Circuit
Eaton Fuller Advantage (2017) Fault Code: 56 PID: 161 SPN: FMI: 4 Input Shaft Speed Sensor: Voltage Below Normal or Shorted Low
Eaton Fuller Advantage (2017) Fault Code: 56 PID: 161 SPN: FMI: 3 Input Shaft Speed Sensor: Voltage Above Normal or Shorted High
Eaton Fuller Advantage (2017) Fault Code: 56 PID: 161 SPN: FMI: 2 Input Shaft Speed Sensor: Data Erratic
Eaton Fuller Advantage (2017) Fault Code: 52 PID: SPN: 59 FMI: 7 Gear Position Sensor: Mechanical System Not Responding

Read more →