Detroit Diesel– Pagina 934– ⛽ Diezel365


Detroit Diesel

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift

Geplaatst door Diezel Solutions op

DESCRIPTION:Outlet NOx sensor is drifted. MONITORED PARAMETER:1. Selective catalyst reduction (SCR) outlet NOx.2. Engine speed between 1000 to 2000 rpm.3. Engine load between 25 to 100%. TYPICAL ENABLING CONDITIONS:1. SCR temperature greater than 390°C (734°F) for 10 seconds.2. Inlet NOx to outlet NOx deviation greater than 200 ppm. MONITOR SEQUENCE:Once per drive cycle. EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:20 seconds DASH LAMPS:None ENGINE REACTION:Dosing is disabled. VERIFICATION:Parked regeneration NOTE: If any other EGR codes are active, fix those first. PROBABLE CAUSES:1. Check the aftertreatment system for leaks/damage.2. Perform a high idle regeneration with the metering valve or dosing...

Meer lezen →


Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 21 (ACM) NOx Outlet Sensor Drift High

Geplaatst door Diezel Solutions op

DESCRIPTION:Outlet NOx sensor drifted high. MONITORED PARAMETER:Selective catalyst reduction (SCR) outlet NOx. TYPICAL ENABLING CONDITIONS:Always enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:Two seconds DASH LAMPS:MIL ENGINE REACTION:None VERIFICATION:Parked regeneration NOTE: If any other EGR codes are active, fix those first. PROBABLE CAUSES:1. Check the aftertreatment system for leaks/damage.2. Perform a high idle regeneration with the metering valve or dosing unit disconnected. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 13 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Signal Not Available Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 4 (ACM) Selective Catalyst Reduction Outlet...

Meer lezen →


Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 3 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed High

Geplaatst door Diezel Solutions op

DESCRIPTION:This code sets when there is a short to power on the SCR outlet NOx circuit between the sensor and CPU. MONITORED PARAMETER:SCR Outlet NOx sensor. TYPICAL ENABLING CONDITIONS:Dewpoint enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:None VERIFICATION:Parked regen NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer. PROBABLE CAUSES:SCR outlet NOx sensor. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 2 (ACM) Selective Catalyst Reduction Outlet NOx Sensor – Drift Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3216 FMI 21 (MCM) Selective Catalyst...

Meer lezen →


Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 4 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed Low

Geplaatst door Diezel Solutions op

DESCRIPTION:This code sets when there is a short to ground on the SCR outlet NOx circuit between the sensor and CPU. MONITORED PARAMETER:SCR outlet NOx sensor. TYPICAL ENABLING CONDITIONS:Dewpoint enabled MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions met. TYPICAL DURATION:Two seconds DASH LAMPS:1. MIL2. CEL ENGINE REACTION:None VERIFICATION:Parked regen NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer. PROBABLE CAUSES:SCR outlet NOx sensor. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 3 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Circuit Failed High Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 2 (ACM) Selective...

Meer lezen →


Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3236 FMI 13 (ACM) Exhaust Mass Signal Not Available via Controller are Network

Geplaatst door Diezel Solutions op

NOTE: Please see the step by step troubleshooting procedures for this specific code. NOTE: If any engine ECMs have been programmed recently, clear codes and release vehicle to customer. NOTE: Otherwise, clear codes, turn key off for 5 minutes, and re-start. If it comes back, use 625-9 to troubleshoot. Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 21 (ACM) NOx Outlet Sensor Drift High Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 13 (ACM) Selective Catalyst Reduction Outlet NOx Sensor Signal Not Available Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3226 FMI 4 (ACM) Selective Catalyst Reduction Outlet...