21 oktober, 2025 Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 3 (CPC) High Voltage NOTE: Please see the step by step troubleshooting procedures for this specific code. PROBABLE CAUSES:Short to power on one of...
21 oktober, 2025 Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 3 (MCM) 5V Sensor Supply Bank 2 Circuit Failed High DESCRIPTION:5V sensor supply bank 2 circuit short to power. MONITORED PARAMETER:Motor Control Module (MCM) 5V internal power supply. TYPICAL ENABLING...
21 oktober, 2025 Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (ACM) Aftertreatment Control Module 2 Sensor Supply 2 Short to Ground DESCRIPTION:5V sensor supply bank 2 circuit failed low. MONITORED PARAMETER:Motor Control Module (MCM) 5V internal power supply. TYPICAL ENABLING CONDITIONS:Always...
21 oktober, 2025 Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (CPC) Accelerator Pedal Supply Voltage Circuit Failed Low DESCRIPTION:Accelerator pedal sensor failed low. MONITORED PARAMETER:Pedal supply voltage. TYPICAL ENABLING CONDITIONS:Always on MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions...
21 oktober, 2025 Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 4 (MCM) 5V Sensor Supply Bank 2 Circuit Failed Low DESCRIPTION:5V Sensor Supply Bank 2 circuit failed high. MONITORED PARAMETER:Motor Control Module (MCM) 5V internal power supply. TYPICAL ENABLING CONDITIONS:Always...
21 oktober, 2025 Detroit DD15 EPA10 (2010-13) Fault Code: SPN 3510 FMI 7 (CPC) Accelerator Pedal Sensor Failed High DESCRIPTION:Accelerator pedal sensor failed high. MONITORED PARAMETER:Pedal supply voltage. TYPICAL ENABLING CONDITIONS:Always on MONITOR SEQUENCE:None EXECUTION FREQUENCY:Continuous when enabling conditions...