Meteen naar de content

Telegram : @Diezel365

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 520249 FMI 4 (ACM) Selective Catalytic Reduction Inlet Temperature High

NOTE: This condition can occur when:
1. MCM pin 2 circuit is shorted to ground.
2. Quantity Control Valve (QCV) internal short to ground.

DESCRIPTION:
Quantity Control Valve (Low Side) Error

MONITORED PARAMETER:
Quantity control valve

TYPICAL ENABLING CONDITIONS:
Always enabled

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met

TYPICAL DURATION:
Two seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
Derate 25%

VERIFICATION:
Engine Idle: One minute.

NOTE: If code 3246-15 present, fix that first.

PROBABLE CAUSES:
1. SCR inlet temperature sensor.
2. SCR inlet temperature sensor connector/harness.

Detroit DD16 EPA10 (2010-13) Fault Code: SPN 520249 FMI 3 (MCM) Quantity Control Valve High Side Driver Error
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 520232 FMI 9 (MCM, CPC, ACM) NOx Mass Signal Not Available via Controller Area Network
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 520231 FMI 13 (MCM, CPC, ACM) Fuel Mass Signal Not Available via Controller Area Network
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 65279 FMI 16 (MCM) Water-In-Fuel (WIF) Ignored-Shutdown
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 65279 FMI 15 (MCM) Water-In-Fuel (WIF) Ignored-Derate
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 5444 FMI 1 (MCM) Engine Crankcase Breather Oil Separator Speed Too Low