Meteen naar de content

Telegram : @Diezel365

Detroit DD16 EPA07 (2007-09) Fault Code: SPN 411 FMI 13 (MCM) EGR Delta Pressure Sensor Out of Calibration

DESCRIPTION:
This fault code sets when the motor control module (MCM) detects that there is EGR pressure when the engine is not running.

MONITORED PARAMETER:
EGR delta pressure.

TYPICAL ENABLING CONDITIONS:
Coolant temperature greater than 80°C (176°F) and ignition is cycled off for 10 seconds.

MONITOR SEQUENCE:
None

EXECUTION FREQUENCY:
Continuous when enabling conditions met.

TYPICAL DURATION:
15 seconds

DASH LAMPS:
1. MIL
2. CEL

ENGINE REACTION:
Derate 25%

VERIFICATION:
1. Run the engine until the coolant temperature is greater than 80°C (176°F).
2. Turn the ignition off for 15 seconds.
3. Turn the ignition on as a recheck for the fault code.

PROBABLE CAUSES:
1. EGR delta p sensor failure.
2. EGR delta p connector/harness.
3. EGR delta p pressure ports blocked.

Detroit DD16 EPA07 (2007-09) Fault Code: SPN 411 FMI 4 (MCM) EGR Delta Pressure Sensor Circuit Failed Low
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 411 FMI 4 (MCM) Exhaust Gas Recirculation Delta P Sensor Short to Ground
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 411 FMI 3 (MCM) EGR Delta Pressure Sensor Circuit Failed High
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 411 FMI 1 (MCM) Exhaust Gas Recirculation Delta P Pressure is Too Low at Low Speeds and Loads
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 411 FMI 0 (MCM) Exhaust Gas Recirculation Delta P Pressure is Too High at Low Speeds and Loads
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 247 FMI 14 (CPC) MCM Reported Ash Mileage is Lower than the CPC Stored Value