DESCRIPTION:CPC output 2 10 short to ground.
MONITORED PARAMETER:CPC output 2 10.
TYPICAL ENABLING CONDITIONS:Always enabled
MONITOR SEQUENCE:None
EXECUTION FREQUENCY:Continuous when enabling conditions met.
TYPICAL DURATION:Two seconds
DASH LAMPS:CEL
ENGINE REACTION:None
VERIFICATION:Engine on with output activation.
NOTE: This code may be set if the engine ECMs were programmed recently or had incorrect parameter changes.
NOTE: Otherwise, there is an open circuit on pin 10 of the CPC4 #2 connector.