DESCRIPTION:Engine coolant inlet temperature circuit failed high.
MONITORED PARAMETER:Engine coolant inlet temperature sensor.
TYPICAL ENABLING CONDITIONS:Always enabled
MONITOR SEQUENCE:None
EXECUTION FREQUENCY:Always enabled
TYPICAL DURATION:Two seconds
DASH LAMPS:1. MIL2. CEL
VERIFICATION:Engine Idle: One minute.
NOTE: If there are any cooling system faults or conditions, repair those first.
PROBABLE CAUSES:1. Inlet coolant temperature sensor.2. Inlet coolant temperature sensor connector/harness.
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 4193 FMI 2 (MCM) Coolant Inlet Temperature Not Plausible
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 4077 FMI 14 (MCM) Hydrocarbon Doser Fuel Line Pressure Failed Self – Test
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 4077 FMI 4 (MCM) Doser Fuel Line Pressure Sensor Circuit Failed Low
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 4077 FMI 3 (MCM) Doser Fuel Line Pressure Sensor Circuit Failed High
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 4041 FMI 16 (CPC) Common Powertrain Controller Internal Failure
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 4041 FMI 9 (CPC) Common Powertrain Controller Internal Failure