DESCRIPTION:High side digital output circuit shorted low.
MONITORED PARAMETER:High side digital output.
EXECUTION FREQUENCY:Continuous when enabling conditions met.
DASH LAMPS:1. MIL2. CEL
NOTE: The supply voltage circuit is networked internal of the Aftertreatment Control Module (ACM). This circuit supplies voltage to the Coolant Valve, Purge-in-Process indicator (if equipped), and the Inlet NOx sensor. A short on any one of those circuits will set this fault code.
PROBABLE CAUSES:1. Coolant valve connector/harness.2. Failed ACM (Aftertreatment Control Module).
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 5016 FMI 3 (ACM) Coolant Valve Supply Voltage Failed High
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 4752 FMI 31 (MCM) Exhaust Gas Recirculation Cooler Performance Monitor
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 4752 FMI 0 (MCM) Exhaust Gas Recirculation Cooler Low Efficiency
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 4375 FMI 6 (ACM) Diesel Exhaust Fluid Pump Supply Current High
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 4375 FMI 5 (ACM) Diesel Exhaust Fluid Pump Circuit Failed Open
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 4375 FMI 4 (ACM) Diesel Exhaust Fluid Pump Circuit Failed Low