Meteen naar de content

Telegram : @Diezel365

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3216 FMI 4 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed Low

DESCRIPTION:This code sets when there is a short to ground on the SCR NOx inlet circuit between the sensor and the CPU.

MONITORED PARAMETER:SCR inlet NOx sensor.

TYPICAL ENABLING CONDITIONS:Dewpoint enabled

MONITOR SEQUENCE:None

EXECUTION FREQUENCY:Continuous when enabling conditions met.

TYPICAL DURATION:Two seconds

DASH LAMPS:1. MIL2. CEL

ENGINE REACTION:None

VERIFICATION:Parked regen

NOTE: If occurrence counter 5 or less, clear codes and return vehicle to customer.

PROBABLE CAUSES:SCR inlet NOx sensor.

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3216 FMI 3 (ACM) Selective Catalyst Reduction Inlet NOx Sensor Circuit Failed High
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3216 FMI 2 (MCM) Selective Catalyst Reduction Inlet NOx Sensor – Drift
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3064 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3058 FMI 13 (MCM) MCM Needs to be Reprogrammed
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3057 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor – Error
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 3056 FMI 2 (ACM) Selective Catalyst Reduction Inlet NOx Sensor – Error