Detroit DD13 EPA10 (2010-13) Fault Code: SPN 2659 FMI 18 (MCM) Exhaust Gas Recirculation Flow Target Error Diagnostic – Low Flow

DESCRIPTION:This fault code sets when the different between the actual EGR flow and the commanded EGR flow is lower than a calibrated threshold.

MONITORED PARAMETER:EGR mass flow

TYPICAL ENABLING CONDITIONS:1. Desired EGR mass flow greater than .08.2. EGR in closed loop control.3. CAC outlet temperature greater than 0°C (32°F).4. Engine speed 1080 to 2500 rpm.5. Engine torque 200 to 2500 N·m (148 to 1844 lb·ft).6. Coolant temperature greater than 65°C (149°F).7. Ambient temperature greater than -8°C (18°F) ambient.8. Barometric pressure greater than 755 mbar (11 psi).

MONITOR SEQUENCE:None

EXECUTION FREQUENCY:Always enabled

TYPICAL DURATION:20

DASH LAMPS:MIL

ENGINE REACTION:None

VERIFICATION:1. Start engine.2. Warm up so that coolant temperature is greater than 65°C (149°F).3. Ensure ambient temperature greater than -8°C (18°F).4. Ambient barometric pressure greater than 755 mbar (11 psi).

PROBABLE CAUSES:1. EGR delta p sensor.2. EGR delta p harness/connector.3. EGR delta p sensor port.4. EGR valve.

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 2659 FMI 0 (MCM) Exhaust Gas Recirculation Flow Target Error Diagnostic – High Flow
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 2631 FMI 4 (MCM, ACM) Intake Manifold Pressure Sensor Circuit Failed Low
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 2631 FMI 3 (MCM, ACM) Intake Manifold Pressure Sensor Circuit Failed High
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 2631 FMI 1 (MCM, ACM) Low Air Flow
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 2630 FMI 16 (MCM) Charge Air Cooler Performance Monitor
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 2630 FMI 3 (MCM) Charger Air Cooler Outlet Temperature Circuit Failed High