DESCRIPTION:EGR Delta Pressure Sensor Circuit High.
MONITORED PARAMETER:EGR delta pressure sensor.
TYPICAL ENABLING CONDITIONS:Always enabled
MONITOR SEQUENCE:None
EXECUTION FREQUENCY:Always enabled
TYPICAL DURATION:2 seconds
DASH LAMPS:1. CEL2. MIL
ENGINE REACTION:Derate 25%
VERIFICATION:Engine Idle: One minute.
PROBABLE CAUSES:1. EGR delta p sensor failure.2. EGR delta p connector/harness.3. EGR delta p pressure ports blocked.
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 411 FMI 1 (MCM) Exhaust Gas Recirculation Delta P Pressure is Too Low at Low Speeds and Loads
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 411 FMI 0 (MCM) Exhaust Gas Recirculation Delta P Pressure is Too High at Low Speeds and Loads
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 247 FMI 14 (CPC) MCM Reported Ash Mileage is Lower than the CPC Stored Value
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 247 FMI 9 (CPC) Typically MCM Engine Hours Data Not Received or Stopped Arriving
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 247 FMI 1 (CPC) MCM Engine Hours Data Lower than Expected
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 247 FMI 0 (CPC) MCM Engine Hours Data Higher than Expected