Meteen naar de content

Telegram : @Diezel365

Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2791 FMI 15 (MCM) High Load Operation in High Ambient Temperatures

NOTE: High load operation in high ambient temperatures. No action is necessary; this is a “silent” fault where the fan will be turned on. This fault is a concern only if the fan-on times are excessive but coolant temperatures are in the normal operating range.

PROBABLE CAUSES:1. If 110-0 is active, repair this first.2. Check for EGR exhaust leaks at the EGR valve actuator.3. Remove the actuator cooler lines and fittings, check for kinks/plugs or leaks.4. EGR valve actuator failure.

Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2791 FMI 14 (MCM) Exhaust Gas Recirculation Valve Actuator Failsafe Mode, Motor ON
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2791 FMI 11 (MCM) Exhaust Gas Recirculation Actuator Restricted Operability
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2791 FMI 10 (MCM) Exhaust Gas Recirculation Actuator Slow Response
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2791 FMI 9 (MCM) Exhaust Gas Recirculation Actuator (Failsafe Mode, Motor OFF)
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2791 FMI 8 (MCM) Exhaust Gas Recirculation Actuator, Failsafe Mode, Motor Off
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2791 FMI 7 (MCM) Exhaust Gas Recirculation Actuator, Failsafe Mode, Motor ON