DESCRIPTION:Charge air cooler (CAC) short to voltage or open.
MONITORED PARAMETER:CAC outlet temperature sensor.
TYPICAL ENABLING CONDITIONS:Always enabled
MONITOR SEQUENCE:None
EXECUTION FREQUENCY:Always enabled
TYPICAL DURATION:Two seconds
DASH LAMPS:CEL
ENGINE REACTION:None
VERIFICATION:Engine Idle: One minute.
PROBABLE CAUSES:1. Intake manifold air temperature sensor failure.2. Intake manifold air temperature sensor harness/connector.
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2630 FMI 2 (MCM) Engine Air Temperature Plausibility Fault Out of Range (High Box)
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2623 FMI 14 (CPC) 2 – Channel Accelerator Pedal GAS1 and GAS2 Signal Missing
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 2623 FMI 4 (CPC) PWM Accelerator Pedal J1939 GAS2 Signal is Missing
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 1845 FMI 9 (CPC) TCFG2 Message is Missing
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 1716 FMI 9 (CPC) ERC1 Message is Missing
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 1663 FMI 7 (MCM, CPC, ACM) Optimized Idle Safety Loop Faulted