Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6791 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High

Lamp:None

Reason:An offset in the Selective Catalytic Reduction (SCR) outlet temperature sensor reading has been detected.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment exhaust gas temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment exhaust gas temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment exhaust gas temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, aftertreatment diesel particulate filter outlet temperature, and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment exhaust gas temperature sensor module and can not be replaced individually.

Component Location:The aftertreatment exhaust gas temperature sensor module is located on the aftertreatment catalyst.

Conditions for Running the Diagnostics:This diagnostic runs when the exhaust gas temperature sensors are compared to other engine temperatures during engine operation. The engine coolant temperature must be above 60°C [140°F] before the diagnostic will run.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the aftertreatment SCR outlet temperature sensor signal was irrational for more than 5 minutes.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.2. A default value for the SCR catalyst outlet temperature is used.3. Diesel exhaust fluid injection into the aftertreatment system is disabled.4. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:1. To validate the repair using a diagnostic road test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.2. To validate the repair using a chassis dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.5. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.6. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. A malfunctioning aftertreatment SCR outlet temperature sensor.2. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.3. For intermittent power supply and datalink communication issues with aftertreatment components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6786 PID: SPN: 3610 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6785 PID: SPN: 3246 FMI: 2/21 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6784 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6783 PID: SPN: 4766 FMI: 2/21 Aftertreatment 1 Diesel Oxidation Catalyst Outlet Gas Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6782 PID: SPN: 4766 FMI: 2/20 Aftertreatment 1 Diesel Oxidation Catalyst Outlet Gas Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6781 PID: SPN: 4765 FMI: 2/21 Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature Sensor – Data Not Rational – Drifted Low

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6792 PID: SPN: 6792 FMI: 2/21 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted Low

Lamp:None

Reason:An offset in the Selective Catalytic Reduction (SCR) outlet temperature sensor reading has been detected.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment exhaust gas temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment exhaust gas temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment exhaust gas temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, aftertreatment diesel particulate filter outlet temperature, and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment exhaust gas temperature sensor module and can not be replaced individually.

Component Location:The aftertreatment exhaust gas temperature sensor module is located on the aftertreatment catalyst.

Conditions for Running the Diagnostics:This diagnostic runs when the exhaust gas temperature sensors are compared to other engine temperatures during engine operation. The engine coolant temperature must be above 60°C [140°F] before the diagnostic will run.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the aftertreatment SCR outlet temperature sensor signal was irrational for more than 5 minutes.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or malfunction indicator lamp (MIL) after the diagnostic fails on two consecutive trips.2. A default value for the SCR catalyst outlet temperature is used.3. Diesel exhaust fluid injection into the aftertreatment system is disabled.4. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:1. To validate the repair using a diagnostic road test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.2. To validate the repair using a chassis dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.5. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.6. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. A malfunctioning aftertreatment SCR outlet temperature sensor.2. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.3. For intermittent power supply and datalink communication issues with aftertreatment components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6791 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6786 PID: SPN: 3610 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6785 PID: SPN: 3246 FMI: 2/21 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6784 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6783 PID: SPN: 4766 FMI: 2/21 Aftertreatment 1 Diesel Oxidation Catalyst Outlet Gas Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6782 PID: SPN: 4766 FMI: 2/20 Aftertreatment 1 Diesel Oxidation Catalyst Outlet Gas Temperature Sensor – Data Not Rational – Drifted High

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6876 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High

Lamp:Amber

Reason:An offset in the SCR outlet temperature sensor reading has been detected.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment SCR (Selective Catalytic Reduction) temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment SCR temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment SCR temperature sensor module is used to measure the aftertreatment SCR intermediate temperature and aftertreatment SCR outlet temperature. The temperature probes are permanently attached to the aftertreatment SCR temperature sensor module and can not be replaced individually.

Component Location:The aftertreatment SCR temperature sensor module is mounted on the aftertreatment SCR catalyst.

Conditions for Running the Diagnostics:This diagnostic runs when the exhaust gas temperature sensors are compared to other engine temperatures during engine operation. The engine coolant temperature must be above 60°C [140°F] before the diagnostic will run.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the aftertreatment SCR outlet temperature sensor reading was out of range high.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.2. A default value for the SCR catalyst outlet temperature is used.3. Diesel exhaust fluid injection into the aftertreatment system is disabled.4. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:1. To validate the repair using a diagnostic road test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.2. To validate the repair using a chassis dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.5. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.6. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. A malfunctioning aftertreatment SCR outlet temperature sensor.2. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.3. For intermittent power supply and datalink communication issues with aftertreatment components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6792 PID: SPN: 6792 FMI: 2/21 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6791 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6786 PID: SPN: 3610 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6785 PID: SPN: 3246 FMI: 2/21 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6784 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6783 PID: SPN: 4766 FMI: 2/21 Aftertreatment 1 Diesel Oxidation Catalyst Outlet Gas Temperature Sensor – Data Not Rational – Drifted Low

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6879 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High

Lamp:Amber

Reason:An offset in the diesel particulate filter outlet temperature sensor reading has been detected.

Effect:Possible reduced engine performance.

Circuit Description:The aftertreatment diesel particulate filter temperature sensor module is a smart device that communicates with the engine control module via the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module performs its own internal diagnostics and reports malfunctions back to the engine control module using the J1939 data link. The aftertreatment diesel particulate filter temperature sensor module is used to measure the aftertreatment diesel oxidation catalyst intake temperature, aftertreatment diesel particulate filter intake temperature, and aftertreatment diesel particulate filter outlet temperature. The temperature probes are permanently attached to the aftertreatment diesel particulate filter temperature sensor module and can not be replaced individually.

Component Location:The aftertreatment diesel particulate filter outlet temperature sensor is located in the aftertreatment system. It is located at the outlet of the aftertreatment diesel particulate filter.

Conditions for Running the Diagnostics:This diagnostic runs continuously when the keyswitch is in the ON position and the engine is running.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the aftertreatment diesel particulate filter outlet temperature signal voltage was out of range high.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or malfunction indicator lamp (MIL) after the diagnostic fails on two consecutive trips.2. A default value for the aftertreatment diesel particulate filter outlet temperature sensor reading is used.3. Diesel exhaust fluid injection into the aftertreatment system is disabled.4. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:1. To validate the repair using a diagnostic road test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.2. To validate the repair using a chassis dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.5. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.6. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. A malfunctioning aftertreatment diesel particulate filter intake temperature sensor.2. A malfunctioning aftertreatment diesel particulate filter outlet temperature sensor.3. Build up or plugging on the inlet face of the diesel particulate filter.4. Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.5. For intermittent power supply and datalink communication issues with aftertreatment components, it is highly recommended that the OEM power distribution center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6876 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6792 PID: SPN: 6792 FMI: 2/21 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6791 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6786 PID: SPN: 3610 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6785 PID: SPN: 3246 FMI: 2/21 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6784 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7232 PID: SPN: 3058 FMI: 0/0 Engine Exhaust Gas Recirculation (EGR) System – Data Valid But Above Normal Operating Range – Most Severe Level

Lamp:Amber

Reason:Measured EGR flow is higher than commanded.

Effect:Possible reduced engine performance.

Circuit Description:The Exhaust Gas Recirculation (EGR) differential pressure sensor has two ports that sense exhaust pressure. The sensor outputs a voltage which represents the pressure difference between the two ports located across an orifice in the EGR tube. The Engine Control Module (ECM) uses this pressure to determine how much exhaust gas is flowing in the EGR connection tube to the intake manifold. This information is used to control the EGR valve for correct emission levels. The ECM provides a 5 volt supply to the EGR differential pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The EGR differential pressure sensor provides a signal to the ECM on the EGR differential pressure sensor signal circuit. This sensor signal voltage changes, based on the differential pressure in the EGR crossover tube. The EGR differential pressure sensor measures the exhaust gas pressure drop across the EGR differential pressure orifice. This pressure drop is used to calculate the amount of EGR flow into the intake manifold.

Component Location:The EGR Valve and EGR differential pressure sensor location varies depending on engine model.

Conditions for Running the Diagnostics:1. This diagnostic runs continuously when the engine is running.2. Ambient air temperature is below a calibrated value.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the measured EGR flow was greater than what was being commanded based on the present engine.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. To validate the repair using a diagnostic road test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.2. To validate the repair using a chassis dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.5. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.6. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault are:1. Blockage, restrictions, or leaks in the EGR differential pressure sensor ports.2. Leaking EGR valve.3. Stuck open EGR valve.4. Malfunctioning EGR differential pressure sensor.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6879 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6876 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6792 PID: SPN: 6792 FMI: 2/21 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6791 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6786 PID: SPN: 3610 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6785 PID: SPN: 3246 FMI: 2/21 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted Low

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7233 PID: SPN: 102 FMI: 1/1 Engine Intake Manifold Pressure – Data Valid But Below Normal Operating Range – Most Severe Level

Lamp:Amber

Reason:Intake manifold pressure is below the minimum operating limit.

Effect:Possible reduced engine performance.

Circuit Description:The Engine Control Module (ECM) provides a 5 volt supply to the intake manifold pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The intake manifold pressure sensor provides a signal to the ECM on the intake manifold pressure sensor signal circuit. This sensor signal voltage changes based on the pressure in the intake manifold.

Component Location:The intake manifold 1 pressure/temperature sensor is located in the air intake manifold.

Conditions for Running the Diagnostics:1. This diagnostic runs continuously when the engine is running.2. Ambient air temperature is below a calibrated value.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the intake manifold pressure reading was below the expected level for the engine operating conditions.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.2. Exhaust gas recirculation (EGR) valve operation will be disabled.3. Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:1. To validate the repair using a diagnostic road test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.2. To validate the repair using a chassis dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.5. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:1. The intake manifold 1 pressure sensor monitors pressure in the intake manifold. This fault is set active when the intake manifold pressure is too low for the present engine operating conditions. The ECM commands a charge flow command and the VGT and EGR valve move to meet this command. If the engine is unable to achieve the desired oxygen level necessary for complete combustion, this fault code is logged.2. Possible causes of this fault are:A. Leaks in the air intake system between the turbocharger and intake manifold.B. A damaged intake manifold pressure sensor.C. A damaged barometric pressure sensor.D. Restriction in the charge-air cooler.E. Leaks or restrictions in the EGR system plumbing.F. Fuel inlet restriction too high (normally caused by a restricted fuel filter).

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7232 PID: SPN: 3058 FMI: 0/0 Engine Exhaust Gas Recirculation (EGR) System – Data Valid But Above Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6879 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6876 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6792 PID: SPN: 6792 FMI: 2/21 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6791 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6786 PID: SPN: 3610 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor – Data Not Rational – Drifted High

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7234 PID: SPN: 188 FMI: 1/17 Engine Speed At Idle – Data Valid But Below Normal Operating Range – Least Severe Level

Lamp:Amber

Reason:Engine is not maintaining the governed idle speed.

Effect:None on performance.

Circuit Description:The Engine Control Module (ECM) continuously monitors the engine speed at idle and adjusts fueling to maintain governed idle speed.

Component Location:The engine speed is monitored by the crankshaft and/or camshaft position sensors.

Conditions for Running the Diagnostics:This diagnostic runs continuously when the engine is operating at idle and PTO is not active.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the engine speed was 50 rpm below governed idle speed for 30 seconds.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.5. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. Fuel system malfunction.2. Crankshaft position sensor malfunction.3. Camshaft position sensor malfunction.4. Increased engine accessory load.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7233 PID: SPN: 102 FMI: 1/1 Engine Intake Manifold Pressure – Data Valid But Below Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7232 PID: SPN: 3058 FMI: 0/0 Engine Exhaust Gas Recirculation (EGR) System – Data Valid But Above Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6879 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6876 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6792 PID: SPN: 6792 FMI: 2/21 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted Low
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6791 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7397 PID: SPN: 102 FMI: 0/0 Engine Intake Manifold Pressure – Data Valid But Above Normal Operating Range – Most Severe Level

Lamp:Amber

Reason:Intake manifold pressure is above the maximum operating limit.

Effect:Possible reduced engine performance.

Circuit Description:The Engine Control Module (ECM) provides a 5 volt supply to the intake manifold pressure sensor on the sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The intake manifold pressure sensor provides a signal to the ECM on the intake manifold pressure sensor signal circuit. This sensor signal voltage changes based on the pressure in the intake manifold.

Component Location:The intake manifold 1 pressure/temperature sensor is located in the air intake manifold.

Conditions for Running the Diagnostics:1. This diagnostic runs continuously when the engine is running.2. Ambient air temperature is below a calibrated value.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) detected the intake manifold pressure reading was higher than expected for the engine operating conditions.

Action Taken When the Fault Code is Active:The ECM illuminates the amber check engine lamp and/or Malfunction Indicator Lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code:1. To validate the repair using a diagnostic road test, utilize a route that incorporates both stop and go city type driving and steady state highway type driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.2. To validate the repair using a chassis dynamometer, utilize a routine that incorporates acceleration and motoring events, steady state highway type operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.3. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.4. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.5. For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.6. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. A malfunctioning variable geometry turbocharger (VGT).2. High exhaust restriction.3. Malfunctioning intake manifold pressure/temperature sensor.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7234 PID: SPN: 188 FMI: 1/17 Engine Speed At Idle – Data Valid But Below Normal Operating Range – Least Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7233 PID: SPN: 102 FMI: 1/1 Engine Intake Manifold Pressure – Data Valid But Below Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7232 PID: SPN: 3058 FMI: 0/0 Engine Exhaust Gas Recirculation (EGR) System – Data Valid But Above Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6879 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6876 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6792 PID: SPN: 6792 FMI: 2/21 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted Low

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 8633 PID: SPN: 12868 FMI: 13/13 TSC1 Control Purpose P7 Inhibit Command – Out of Calibration

Lamp:None

Reason:The ECM expected information from a multiplexed device but only received a portion of the necessary information.

Effect:At least one multiplexed device will not operate properly.

Circuit Description:Normally, switches, accelerators, and other components are connected to the Engine Control Module (ECM) directly through individual wires. Multiplexing allows those same components to be hard wired to an Original Equipment Manufacturer (OEM) Vehicle Electronic Control Unit (VECU) or transmission Electronic Control Unit (ECU) in the cab. Then component values and states from components such as sensors, accelerators, and switches can be transmitted from the OEM VECU to the OEM ECM over the SAE J1939 data link. Messages sent from OEM VECUs or transmission ECUs are received by the OEM ECM and used for controlling the engine. The OEM ECM and OEM VECUs must be configured properly so that proper operation of the multiplexed components will occur.

Component Location:The SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the Diagnostics:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Code:The Engine Control Module (ECM) received an invalid J1939 data link message from a multiplexed device for more than 1 second.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp immediately when the diagnostic runs and fails.2. The multiplexed device will not operate.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. The “reset all faults” command in the recommended diagnostic tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:Possible causes of this fault code include:1. This fault can occur when the ECM is set up properly (components enabled and OEM VECU source addressed correctly) to receive information from an OEM VECU, but the OEM VECU is actually transmitting a message that says that component is not available for multiplexing.2. It is possible to use the recommended diagnostic tool or equivalent to monitor multiplexed components.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7397 PID: SPN: 102 FMI: 0/0 Engine Intake Manifold Pressure – Data Valid But Above Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7234 PID: SPN: 188 FMI: 1/17 Engine Speed At Idle – Data Valid But Below Normal Operating Range – Least Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7233 PID: SPN: 102 FMI: 1/1 Engine Intake Manifold Pressure – Data Valid But Below Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7232 PID: SPN: 3058 FMI: 0/0 Engine Exhaust Gas Recirculation (EGR) System – Data Valid But Above Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6879 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6876 PID: SPN: 4363 FMI: 2/20 Aftertreatment 1 SCR Outlet Temperature Sensor – Data Not Rational – Drifted High

Read more →

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 8634 PID: SPN: 12868 FMI: 9/9 TSC1 Control Purpose P7 Inhibit Command – Abnormal Update Rate

Lamp:None

Reason:The ECM expected information from a multiplexed device but did not receive it soon enough or did not receive it at all.

Effect:At least one multiplexed device will not operate properly.

Circuit Description:Normally, switches, accelerators, and other components are connected to the Engine Control Module (ECM) directly through individual wires. Multiplexing allows those same components to be hard wired to an Original Equipment Manufacturer (OEM) Vehicle Electronic Control Unit (VECU) or transmission Electronic Control Unit (ECU) in the cab. Then component values and states from components such as sensors, accelerators, and switches can be transmitted from the OEM VECU to the OEM ECM over the SAE J1939 data link. Messages sent from OEM VECUs or transmission ECUs are received by the OEM ECM and used for controlling the engine. The OEM ECM and OEM VECUs must be configured properly so that proper operation of the multiplexed components will occur.

Component Location:The SAE J1939 data link wiring and the SAE J1939 devices vary by OEM options.

Conditions for Running the Diagnostics:This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Code:1. The Engine Control Module (ECM) did not receive a message from a multiplexed device.2. The Engine Control Module (ECM) detected an open or short circuit condition in the J1939 data link harness.

Action Taken When the Fault Code is Active:1. The ECM illuminates the amber check engine lamp immediately when the diagnostic runs and fails.2. The multiplexed device will not operate.

Conditions for Clearing the Fault Code:1. To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.2. The fault code status displayed by the recommended diagnostic tool or equivalent will change to inactive immediately after the diagnostic runs and passes.3. The ECM will turn off the amber check engine lamp immediately after the diagnostic runs and passes.4. The “reset all faults” command in the recommended diagnostics tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:1. When this fault code is active, some multiplexed devices can possibly not function as desired.2. Possible causes of this fault code include:A. When the ECM is set up properly (components enabled and OEM VECU source addressed correctly) to receive information from an OEM VECU, but the OEM VECU is actually transmitting a message that says that component is not available for multiplexing. This can be caused when a multiplexed component is enabled in the ECM, but the OEM VECU source address of the VECU transmitting the component message is incorrect in the OEM ECM, or the OEM VECU is not set up to transmit the multiplexed component message.B. This fault can also be caused by a bad J1939 data link connection between the OEM VECU and OEM ECM, a bad connection between the component and the OEM VECU, bad OEM VECU or bad OEM ECM. It may be necessary to contact the OEM for proper multiplexing configuration. It is possible to use the recommended diagnostic tool or equivalent to monitor multiplexed components.C. It is possible to use the recommended diagnostic tool or equivalent to monitor multiplexed components.

Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 8633 PID: SPN: 12868 FMI: 13/13 TSC1 Control Purpose P7 Inhibit Command – Out of Calibration
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7397 PID: SPN: 102 FMI: 0/0 Engine Intake Manifold Pressure – Data Valid But Above Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7234 PID: SPN: 188 FMI: 1/17 Engine Speed At Idle – Data Valid But Below Normal Operating Range – Least Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7233 PID: SPN: 102 FMI: 1/1 Engine Intake Manifold Pressure – Data Valid But Below Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 7232 PID: SPN: 3058 FMI: 0/0 Engine Exhaust Gas Recirculation (EGR) System – Data Valid But Above Normal Operating Range – Most Severe Level
Cummins X15 CM2350 X116B Performance Series (2018 & Newer) Fault Code: 6879 PID: SPN: 3246 FMI: 2/20 Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor – Data Not Rational – Drifted High

Read more →